PD865 Snooper Modbus
Serial Input Meter
Instruction Manual
12
Isolated 4-20 mA Transmitter Output
CALIBRATION
Factory calibrated for 4-20 mA
SCALING RANGE 1.000 to 23.000 mA for any display range.
Reverse scaling allowed.
ACCURACY
± 0.1% F.S. ± 0.004 mA
TEMPERATURE
DRIFT
50 PPM/
C from 0 to 65
C ambient
EXTERNAL LOOP
POWER SUPPLY
35 VDC maximum
OUTPUT LOOP
RESISTANCE
Power supply
Minimum
Maximum
24 VDC
10
700
35 VDC (external)
100
1200
DATA
SOURCE
Display Value, Maximum Display Value, Minimum Display
Value, or Modbus Register.
OVERRANGE
Programmable mA output for overrange condition.
UNDERRANGE
Programmable mA output for underrange condition.
COMMUNICA-
TIONS BREAK
Programmable mA output when a slave device does not
reply within the Slave Response Timeout (Available also in
Slave mode v1.1 & up).
MAXIMUM
OUTPUT
Programmable absolute maximum mA output desired.
MINIMUM
OUTPUT
Programmable absolute minimum mA output desired.