1.1 SPECIFICATIONS
General
DISPLAY
Dual 4 digits, red LED, -1999 to 9999
DIN Sizes
PV Display
SP Display
Weight
mm (inch)
mm (inch)
g (oz)
1/8
19.8 (0.78)
11.5 (0.45)
306 (10.6)
1/4
20.5 (0.81)
11.0 (0.43)
389 (13.7)
FRONT PANEL
1/8 DIN: IP65; 1/4 DIN: IP55
SAMPLING TIME
250 ms
OVERRANGE
Over range PV reads
ovR
, under range PV reads
-ovR
PROGRAMMING
Four front panel buttons, Modbus
METHODS
NOISE FILTER
Programmable from 1 to 120
CALIBRATION
All ranges are calibrated at the factory
MAX/MIN
Max/min readings reached by the process are stored until
DISPLAY
reset by the user or until power to the meter is turned off.
PASSWORD
Programmable password restricts modification of
programmed settings
POWER
100-240 VAC, 50/60 HZ, 10 Watts
FUSE
Required fuse: UL Recognized, 1 A, 250 V, slow blow
ISOLATION
2300 V input-to-output-to-power line;
4 kV relay output-to-input/output/power line
ENVIRONMENTAL
Operating temperature range: 10ºC to 50ºC (50ºF to 110ºF)
Relative humidity: 20 to 90% non-condensing
MOUNTING
1/8 or 1/4 DIN size cutout required
Two panel mounting bracket assemblies provided
WARRANTY
Three years parts and labor
EXTENDED
Extended parts and labor warranties are available at time of
WARRANTY
ordering
Retransmitting Output
OUTPUT RANGE
Retransmitting: 4 to 20 mA (600
Ω
maximum)
SCALING RANGE
Any display range (see range for the input selected)
ACCURACY
+0.1% of full scale
Except where noted all specifications apply to operation at 23ºC.