Except where noted all specifications apply to operation at +25°C.
General
Display:
Upper display: 0.60" (15 mm) high. Lower display: 0.46" (12 mm)
high. Both are 6 digits (-99999 to 999999), red LEDs.
Default Display a ssignment: t
he upper display shows batch total. The
lower display shows rate with alternating units, and can be switched to
show grand total, batch count, or preset with the STOP key.
c ustom Display a ssignment:
The upper and lower displays may be
assigned to rate, total, grand total, batch count, preset, set points, units
(lower display only), alternating R & T, R & GT, preset & rate, max & min,
or a Modbus display register. Any rate/total/grand total display may be
programmed to alternate with a custom unit or tag.
a lternating Display:
Displays alternate every 10 seconds when display is
selected or the batch is paused.
Display Intensity:
Eight user selectable intensity levels
Display Update r ate:
5/second (200 ms)
o verrange:
Display flashes 999999
Underrange:
Display flashes -99999
Front Panel:
NEMA 4X, IP65
o perating methods:
Three programmable front panel buttons (default
START, BATCH, STOP), digital inputs, PC and MeterView Pro software,
and Modbus registers.
Programming methods:
Four front panel buttons, digital inputs, PC and
MeterView Pro software, Modbus registers, or cloning using Copy function.
F4 Digital Input c ontacts:
3.3 VDC on contact. Connect normally open
contacts across F4 to COM.
F4 Digital Input l ogic l evels:
Logic High: 3 to 5 VDC
Logic Low: 0 to 1.25 VDC
noise Filter:
Programmable from 2 to 199 (0 will disable filter)
Filter Bypass:
Programmable from 0.1 to 99.9% of calibrated span.
r ecalibration:
Recommended at least every 12 months.
max/min Display:
Max (Peak) / min (Valley) readings reached by the
process are stored until reset by the user or until power is cycled.
Password:
Three programmable passwords restrict modification of
programmed settings and two prevent resetting the totals.
non-Volatile memory:
All programmed settings are stored in non-volatile
memory for a minimum of ten years if power is lost.
Power o ptions:
85-265 VAC 50/60 Hz, 90-265 VDC, 20 W max, or
optional model with 12-24 VDC ±10%, 15 W max.
Fuse:
Required external fuse: UL Recognized, 5 A max, slow blow; up to 6
controllers may share one 5 A fuse.
Isolated t ransmitter Power supply:
Terminals P+ & P-: 24 VDC ± 10%.
Internally selectable jumper for 24, 10, or 5 VDC supply.
85-265 VAC models rated @ 200 mA max, 12-24 VDC powered models
rated @ 100 mA max, @ 50 mA max for 5 or 10 VDC supply.
normal r ejection mode:
Greater than 60 dB at 50/60 Hz (PD6210)
Isolation:
4 kV input/output-to-power line. 500 V input-to-output or
output-to-P+ supply.
o vervoltage c ategory:
Installation Overvoltage Category II: Local level with
smaller transient overvoltages than Installation Overvoltage Category III.
environmental:
Operating temperature range: -40 to 65°C
Storage temperature range: -40 to 85°C
Relative humidity: 0 to 90% non-condensing
c onnections:
Removable screw terminal blocks accept 12 to 22 AWG wire,
RJ45 for external relays, digital I/O, and serial communication adapters.
enclosure:
1/8 DIN, high impact plastic, UL 94V-0, color: black
mounting:
1/8 DIN panel cutout required: 3.622" x 1.772" (92 mm x 45 mm).
w eight:
9.5 oz. (269 g)
Dimensions:
4.68" x 2.45" x 5.64" (119 mm x 62 mm x 143 mm) (W x H x D)
Ul File number:
UL & c-UL Listed. E160849; 508 Industrial Control Equipment.
warranty:
3 years parts & labor
UsB c onnection:
Compatibility: USB 2.0 Standard, Compliant
Connector Type: Micro-B receptacle
Cable: USB A Male to Micro-B Cable
Driver: Windows 98/SE, ME, 2000, Server 2003/2008, XP 32/64-Bit,
Vista 32/64-Bit, Windows 7 32/64-Bit, Windows 10 32/64-Bit
Power: USB Port
c onnect Ions
PD6210
PD6310
nema 4, nema 4X, an D
eXPlos Ion- Proo F enclos Ures
Thermoplastic and stainless steel NEMA 4X, and painted steel NEMA
4 enclosures are available. Also available is the ProtEX-MAX for
hazardous area applications requiring explosion-proof enclosures.
Visit our website at
www.predig.com
for more information.
PDa 2811
Plastic Low-Cost
PD8 series
ProteX-maX
R
I-
I+
MA OUT
1
3
2
POWER
+ -
SIGNAL
P-
COM
P+
V+ mA+
3
4
1
2
5
M-LINK
C
NO
NO
NC
NC
C
RELAY4
RELAY3
4
3
6
5
2
1
C
NO
NO
NC
NC
C
RELAY2
RELAY1
4
3
6
5
2
1
1 2 3 4 5 6 7 8
2
1
F4
6
4-20 mA Output
Powered by P
RO
V
U
for Rate or Total
Transmitter
Powered by P
RO
V
U
+
+
-
-
• Form C (SPDT) relays
• Two isolated power supplies available even on
12-24 VDC input power models
• Removable terminal blocks
• 2 or 4 isolated 4-20 mA output option
• Universal 85-265 VAC or 12-24 VDC
input power
• Voltage or current inputs
• No jumpers needed for V/mA input
selection
• M-Link for adding expansion modules
• Digital Input (F4) is standard
P-
COM
P+
S+
S-
3
4
1
2
5
F4
6
mV PNP NPN
SWITCH
C
C
4-20 mA Output
Powered by P
RO
V
U
for Rate or Total
+
-
Flowmeter
• Form C (SPDT) relays
• Two isolated power supplies available even on
12-24 VDC input power models
• Removable terminal blocks
• 2 or 4 isolated 4-20 mA output option
• Universal 85-265 VAC or 12-24 VDC
input power
• M-Link for adding expansion modules
• Digital Input (F4) is standard
PDa 2600
Stainless Steel