PD6210 / PD6310 

P

ro

V

U

®

 

Batch c ontrollers

sPec IFIca t Ions

Except where noted all specifications apply to operation at +25°C.

General

Display:

 Upper display: 0.60" (15 mm) high. Lower display: 0.46" (12 mm) 

high. Both are 6 digits (-99999 to 999999), red LEDs.

Default Display a ssignment: t

he upper display shows batch total. The 

lower display shows rate with alternating units, and can be switched to 
show grand total, batch count, or preset with the STOP key.

c ustom  Display a ssignment:

 The upper and lower displays may be 

assigned to rate, total, grand total, batch count, preset, set points, units 
(lower display only), alternating R & T, R & GT, preset & rate, max & min, 
or a Modbus display register. Any rate/total/grand total display may be 
programmed to alternate with a custom unit or tag.

a lternating Display:

 Displays alternate every 10 seconds when display is 

selected or the batch is paused.

Display Intensity:

 Eight user selectable intensity levels

Display Update r ate:

 5/second (200 ms)

o verrange:

 Display flashes 999999

Underrange:

 Display flashes -99999

Front Panel:

 NEMA 4X, IP65

o perating  methods: 

Three programmable front panel buttons (default 

START, BATCH, STOP), digital inputs, PC and MeterView Pro software, 
and Modbus registers.

Programming methods:

 Four front panel buttons, digital inputs, PC and 

MeterView Pro software, Modbus registers, or cloning using Copy function.

F4 Digital Input c ontacts:

 3.3 VDC on contact. Connect normally open 

contacts across F4 to COM.

F4 Digital Input l ogic l evels:

 Logic High: 3 to 5 VDC 

Logic Low: 0 to 1.25 VDC

noise Filter:

 Programmable from 2 to 199 (0 will disable filter)

Filter Bypass:

 Programmable from 0.1 to 99.9% of calibrated span.

r ecalibration:

 Recommended at least every 12 months.

max/min Display:

 Max (Peak) / min (Valley) readings reached by the 

process are stored until reset by the user or until power is cycled.

Password:

 Three programmable passwords restrict modification of 

programmed settings and two prevent resetting the totals. 

non-Volatile memory:

 All programmed settings are stored in non-volatile 

memory for a minimum of ten years if power is lost.

Power o ptions:

 85-265 VAC 50/60 Hz, 90-265 VDC, 20 W max, or 

optional model with 12-24 VDC ±10%, 15 W max.

Fuse:

 Required external fuse: UL Recognized, 5 A max, slow blow; up to 6 

controllers may share one 5 A fuse.

Isolated t ransmitter Power supply:

 Terminals P+ & P-: 24 VDC ± 10%. 

Internally selectable jumper for 24, 10, or 5 VDC supply.  
85-265 VAC models rated @ 200 mA max, 12-24 VDC powered models 
rated @ 100 mA max, @ 50 mA max for 5 or 10 VDC supply.

normal r ejection mode:

 Greater than 60 dB at 50/60 Hz (PD6210)

Isolation:

 4 kV input/output-to-power line. 500 V input-to-output or 

output-to-P+ supply.

o vervoltage c ategory:

 Installation Overvoltage Category II: Local level with 

smaller transient overvoltages than Installation Overvoltage Category III.

environmental:

 Operating temperature range: -40 to 65°C 

Storage temperature range: -40 to 85°C 
Relative humidity: 0 to 90% non-condensing 

c onnections:

 Removable screw terminal blocks accept 12 to 22 AWG wire, 

RJ45 for external relays, digital I/O, and serial communication adapters.

enclosure:

 1/8 DIN, high impact plastic, UL 94V-0, color: black

mounting:

 1/8 DIN panel cutout required: 3.622" x 1.772" (92 mm x 45 mm).

w eight:

 9.5 oz. (269 g)

Dimensions:

 4.68" x 2.45" x 5.64" (119 mm x 62 mm x 143 mm) (W x H x D)

Ul  File number:

 UL & c-UL Listed. E160849; 508 Industrial Control Equipment.

warranty:

 3 years parts & labor

UsB c onnection:

 Compatibility: USB 2.0 Standard, Compliant

Connector Type: Micro-B receptacle 
Cable: USB A Male to Micro-B Cable
Driver: Windows 98/SE, ME, 2000, Server 2003/2008, XP 32/64-Bit, 
Vista 32/64-Bit, Windows 7 32/64-Bit, Windows 10 32/64-Bit
Power: USB Port

c onnect Ions

PD6210

PD6310

nema  4, nema  4X, an D 

eXPlos Ion- Proo F enclos Ures

Thermoplastic and stainless steel NEMA 4X, and painted steel NEMA 
4 enclosures are available. Also available is the ProtEX-MAX for 
hazardous area applications requiring explosion-proof enclosures. 
Visit our website at 

www.predig.com

 for more information.

PDa 2811

Plastic Low-Cost

PD8 series

ProteX-maX

R

I-

I+

MA OUT

1

3

2

POWER

+ -

SIGNAL

P-

COM

P+

V+ mA+

3

4

1

2

5

M-LINK

C

NO

NO

NC

NC

C

RELAY4

RELAY3

4

3

6

5

2

1

C

NO

NO

NC

NC

C

RELAY2

RELAY1

4

3

6

5

2

1

1 2 3 4 5 6 7 8

2

1

F4

6

4-20 mA Output

Powered by P

RO

V

U

for Rate or Total

Transmitter

Powered by P

RO

V

U

+

+

-

-

• Form C (SPDT) relays

• Two isolated power supplies available even on

  12-24 VDC input power models

• Removable terminal blocks

• 2 or 4 isolated 4-20 mA output option

• Universal 85-265 VAC or 12-24 VDC

  input power

• Voltage or current inputs

• No jumpers needed for V/mA input 

  selection

• M-Link for adding expansion modules

• Digital Input (F4) is standard

P-

COM

P+

S+

S-

3

4

1

2

5

F4

6

mV    PNP  NPN   

SWITCH

C

C

4-20 mA Output

Powered by P

RO

V

U

for Rate or Total

+

-

Flowmeter

• Form C (SPDT) relays

• Two isolated power supplies available even on

  12-24 VDC input power models

• Removable terminal blocks

• 2 or 4 isolated 4-20 mA output option

• Universal 85-265 VAC or 12-24 VDC

  input power

• M-Link for adding expansion modules

• Digital Input (F4) is standard

PDa 2600

Stainless Steel

Содержание PRO VU Series

Страница 1: ...ture C ount Up or Down with Each Batch C ommon PRO VU METER Fea t ures NEMA 4X IP65 Front Input Power O ptions Include 85 265 VAC or 12 24 VDC Dual L ine 6 Digit Display 0 60 0 46 Programmable Displays Function Keys O ptional SunBright Display Models for O utdoor A pplications 2 or 4 R elays Isolated 4 20 mA Output Options External 4 R elay Digital I O Expansion Modules RS 232 RS 485 Serial C ommu...

Страница 2: ...may be displayed in the lower display with password protection and non resettable programmable features Dual Line 6 Character Display Large 0 6 Digits Rugged Front Batch Preset Current Batch Quantity Start Batch Preset Stop Keys Batch Control Alarm Relays Total Super Bright LEDs make Standard and SunBright Display Models Even Brighter The PROVU s standard and SunBright display models feature extra...

Страница 3: ...CH key is configured by default to access the preset menu The preset may be changed quickly and easily between batches without the need to enter setup menus Non R esettable Grand T otal The user can set up the grand total to be non resettable by entering a specific password Once this is done the grand total can never be reset T otal C onversion Factor The user can enter a conversion factor that al...

Страница 4: ...keys on the front panel without a password Level 2 protection allows the operator use of only the function keys and the ability to change set points without a password Level 3 protection restricts the function keys and all configuration menus without a password Grand total reset protection prevents the total from being reset manually R ugged A unique front panel design makes the PROVU nearly impen...

Страница 5: ...batch total equals the preset amount the restricted flow valve closes The barrel is now full If some overrun occurs the next batch will adjust for this offset amount to maintain accuracy C hange Preset After placing a new empty barrel a new preset fill amount may be selected with the Batch key while the process is stopped Begin New Batch Press the START key and a new batch will begin With both val...

Страница 6: ...ls rated 200 mA max 12 24 VDC powered models rated 100 mA max 50 mA max for 5 or 10 VDC supply Normal R ejection Mode Greater than 60 dB at 50 60 Hz PD6210 Isolation 4 kV input output to power line 500 V input to output or output to P supply O vervoltage C ategory Installation Overvoltage Category II Local level with smaller transient overvoltages than Installation Overvoltage Category III Environ...

Страница 7: ... illuminated while displaying batch total and GT for grand total Up to 999 999 999 with total overflow feature oF is displayed to the left of grand total overflow and LED is illuminated Batch T otal Decimal Point Up to five decimal places or none d ddddd dd dddd ddd ddd dddd dd ddddd d or dddddd Total decimal point is independent of rate decimal point T otalizer Calculates total based on rate and ...

Страница 8: ...loads or der ing informa t ion PRO VU PD6210 A nalog Input 85 265 VAC Model 12 24 VDC Model O ptions Installed PD6210 6R2 PD6210 7R2 2 Relays PD6210 6R4 PD6210 7R4 4 Relays PD6210 6R5 PD6210 7R5 2 Relays 4 20 mA Output PD6210 6R7 PD6210 7R7 4 Relays 4 20 mA Output To order SunBright display models replace the R with H i e PD6210 6H2 Note 24 V flowmeter power supply standard on all models PRO VU PD...

Отзывы: