PDW30 Point-to-Point Wireless Bridge Instruction Manual
20
Secondary Device Menus
The secondary device has less menu options than the primary device, shown below.
Display Signal I/O and Digital I/O Status
Pressing either the
previous
or
display
buttons while the device is in run mode will cycle through the dis-
play modes. These modes are, in order,
link status
,
analog I/O
, and
digital I/O
.
LINK OK
SEC RSSI 10 RT
NOW: 01
NETWORK ID
NOW: 4-20mA
ANALOG INPUT
NOW: 0.2 SEC
MODBUS TIMEOUT
SETUP
PASSWORD
DEFAULTS
RESTORE
Run Mode
SET: 01
NETWORK ID
increments selected digit.
selects next digit to the right.
SET: 4-20mA
ANALOG INPUT
SET: 0-10V
ANALOG INPUT
SET: 0-5V
ANALOG INPUT
SET: 1-5V
ANALOG INPUT
NOW: 0000
PASSWORD (0=OFF)
SETUP MENU
BACK TO
SET: 0123
PASSWORD (0=OFF)
increments selected digit.
selects next digit to the right.
0000
disables the password.
NO
LOAD DEFAULTS?
YES
LOAD DEFAULTS?
Unit will load default
settings and reboots.
SET: 0.2 SEC
MODBUS TIMEOUT
SET: 0.5 SEC
MODBUS TIMEOUT
SET: 1 SEC
MODBUS TIMEOUT
SET: 0.1 SEC
MODBUS TIMEOUT
LINK OK
PRI RSSI 10 RT
AOUT: 20.00 mA
AIN: 20.00 mA
DO3:OFF DI4:OFF
DI1:ON DO2:ON