PD4-6624 & PD4-6628 Loop-Powered Flow Rate/Totalizers
Instruction Manual
30
Display Functions & Messages
The meter displays various functions and messages during
setup, programming, and operation. The following table
shows the main menu functions and messages in the order
they appear in the menu.
Parameter
Action/Setting Description
INPUT
Program the meter 4-20 mA input
SCALE RATE
Scale the rate input
UNITS
Select the display units
/SECOND
Units per second
/MINUTE
Units per minute
/HOUR
Units per hour
/DAY
Units per day
GAL/
(T)
Gallons per time unit (T)
L/
(T)
Liters per time unit (T)
IGAL/
(T)
Imperial gallons per time unit (T)
M3/
(T)
Cubic meters per time unit (T)
BBL/
(T)
Barrels per time unit (T)
BUSH/
(T)
Bushels per time unit (T)
cuYD/
(T)
Cubic Yards per time unit (T)
cuFt/
(T)
Cubic Feet per time unit (T)
cuIn/
(T)
Cubic Inches per time unit (T)
LiBBL/
(T)
Liquid barrels per time unit (T)
BBBL/
(T)
Beer barrels per time unit (T)
HECtL/
(T)
Hectoliter per time unit (T)
AF/
(T)
Acre-Foot per time unit (T)
CUSTOM/
(T)
Custom unit per time unit (T)
INPUT 1
Program input 1 value
INP 1
Enter the input 1 value
DISP 1
Program display 1 value
DSP 1
Enter the display 1 value
INPUT 2
Program input 2 value (up to 32
points)
INP 2
Enter the input 2 value
DISP 2
Program display 2 value (up to 32
points)
DSP 2
Enter the display 2 value
SAVE?
Save programmed units, input,
and display values
OUTPUT
Program the meter’s available
outputs
OPEN COLLECTR
Program the meter’s open
collector outputs
OUTPUT1
Open collector 1 setup
OUTPUT2
Open collector 2 setup
DISABLE
Disable the open collector
Parameter
Action/Setting Description
PULSE
Program the open collector for
pulse output
ALARM
Program the open collector for
alarm output
TIMER
Program the open collector as a
timer
TOT RST
Program the open collector for
total reset
STPWATCH
Program the open collector to turn
on while the stopwatch is running
RELAY
Program the meter’s relay outputs
OUTPUT1
Relay 1 setup
OUTPUT2
Relay 2 setup
DISABLE
Disable the relay
ALARM
Program relay for alarm
functionality
SAMPLE
Program relay for sample
functionality
TIMER
Program relay as a timer
BATCH
Program the relay for batch control
functionality
STPWATCH
Program relay to turn on while the
stopwatch is running
INFO
View relay run time and cycle
count
4-20 mA
Program the
meter’s 4-20 mA
output
RATE
Transmit a value based on the rate
display
TOTAL
Transmit a value based on the
total display
RETRANS
Retransmit the 4-20 mA input
signal
DISABLE
Disable the 4-20 mA output
CONTROL
Program manual or automatic
operation for the outputs
OC1
Open collector 1
OC2
Open collector 2
RELAY1
Relay 1
RELAY2
Relay 2
4-20 mA
4-20 mA output
AUTO
Set selected output to automatic
operation
MANUAL
Manually control selected output
operation
ADVANCED
Program the meter’s advanced
features
RATE
Advanced 4-20 mA rate input
programming