One Place Monitor Panel

Trouble Shooting Generator Function

Voltage between Pins 4 and 1 should be +12V when the Generator is running, and 
change the display from “Stopped” to “Running”.

While Pressing and Holding the Generator Stop Button, pin 2 Stop voltage should go to 
zero, and return to +12V when the Button is released.

Make Sure Generator is not already running.  
While Pressing and Holding the Generator Start Button, pin 3 Start voltage should go to 
zero, and return to +12V when the Button is released.

Note:  Semi-automatic functions will operate as long as the above three tests perform 
properly.

IN DI CATOR

STA R T

STOP

GROU ND

2

1

J1

Содержание One Place

Страница 1: ...ON OFF FAIL 2 Touch to turn Electric Water Heater On and Off Display will be or ON OFF 1 Touch to turn Water Pump On and Off Display will be or Works with separate Water Pump Control and switches in m...

Страница 2: ...tric Button to toggle between On and Off Place Voltmeter between pins 1 and 5 of the connector When Water Heat LP is On Voltage should be 12V When Water Heat LP is Off Voltage should be 0 Momentarily...

Страница 3: ...ste Tank F Fresh Water Tank 2 3 L P Gas Tank E Gra y1 Waste Tnk 1 3 Gra y2 Waste Tnk 1 3 Black1 Waste Tnk F Black2 Waste Tnk F 6 Pressing Tank Levels switch brings you to this screen The screen will c...

Страница 4: ...r pad should be sending a signal Placing a piece of sheet metal next to either of the top two sensors should change the display from 1 3 to 2 3 In this way each individual sensor pad can be tested Tro...

Страница 5: ...and the Panel will attempt to start the Generator automatically Display Auto Start If the Auto Start functions fails to start the Generator Display Will Not Start Stop Button a Pressing and holding St...

Страница 6: ...ning While Pressing and Holding the Generator Stop Button pin 2 Stop voltage should go to zero and return to 12V when the Button is released Make Sure Generator is not already running While Pressing a...

Страница 7: ...ry Power is removed from the Panel The One Place Monitor Panel has many safe guards to prevent improperly learning a feature Should the Panel have learned something incorrectly an option exists on the...

Отзывы: