Meter

Heater

Electric

Heater

L. P.

Tank

Pump

Battery

GenSet

Water

Levels

W a t e r

P u m p

O N

W a t e r

H e a t E l e c

O F F

W a t e r

H e a t L . P .

FA IL

3. Touch to turn L.P. Water Heater On and Off.  Display will be 

or 

, if the L.P. Heater fails to light.

ON  OFF

  FAIL

  

2. Touch to turn Electric Water Heater On and Off.  Display will be 

, or

.

ON

   OFF   

1. Touch to turn Water Pump On and Off.  Display will be 

, or  

.  

Works with separate Water Pump Control, and switches in multiple locations.  
Displays status of Water Pump, no matter where switch is pressed.

ON

 OFF

4. Generator Switches. See #4 below for detailed operation.

5. Battery Level Switch. See #5 below.

6. Tank Level; Fresh, Gray, Black & L.P. See #6 below.

To conserve Battery power, after 1 minute Backlighting will go off, and display will return to this Default Screen.  However, the Panel is still live.

Содержание One Place

Страница 1: ...ON OFF FAIL 2 Touch to turn Electric Water Heater On and Off Display will be or ON OFF 1 Touch to turn Water Pump On and Off Display will be or Works with separate Water Pump Control and switches in m...

Страница 2: ...tric Button to toggle between On and Off Place Voltmeter between pins 1 and 5 of the connector When Water Heat LP is On Voltage should be 12V When Water Heat LP is Off Voltage should be 0 Momentarily...

Страница 3: ...ste Tank F Fresh Water Tank 2 3 L P Gas Tank E Gra y1 Waste Tnk 1 3 Gra y2 Waste Tnk 1 3 Black1 Waste Tnk F Black2 Waste Tnk F 6 Pressing Tank Levels switch brings you to this screen The screen will c...

Страница 4: ...r pad should be sending a signal Placing a piece of sheet metal next to either of the top two sensors should change the display from 1 3 to 2 3 In this way each individual sensor pad can be tested Tro...

Страница 5: ...and the Panel will attempt to start the Generator automatically Display Auto Start If the Auto Start functions fails to start the Generator Display Will Not Start Stop Button a Pressing and holding St...

Страница 6: ...ning While Pressing and Holding the Generator Stop Button pin 2 Stop voltage should go to zero and return to 12V when the Button is released Make Sure Generator is not already running While Pressing a...

Страница 7: ...ry Power is removed from the Panel The One Place Monitor Panel has many safe guards to prevent improperly learning a feature Should the Panel have learned something incorrectly an option exists on the...

Отзывы: