background image

 

HG-1 WR 80M AND 60M OPERATION 

The HG-1WR is capable for 60m and 80m operation. Because of performance optimization circuit boards with 
isolation jumpers are used to connect external the 60m and 80m resonators. These circuit boards are mounted 
on each side of the case. See figure below.  

 

These boards are identical. On these boards there is a solder jumper labeled 60/80M JUMPER JP1.  See figure 
below: 

 

These jumpers isolate the banana jack inputs and must be bridged. For 60/80-meter operation create a solder 
bridge on both boards. Heat the pads and apply sufficient solder to bridge the pads. 

The Banana jacks are mounted on the top of the case and are water resistant. The external resonator can be 
inserted approximately 2/3 into the jacks and will fit securely. 

Tuning is done with the main resonating tuning capacitor as in 40-10-meter operation. 

 

DIFFERENCES BETWEEN MANUAL AND REMOTE TUNING  

When tuning manually the operator tunes for a peak receiver signal by rapidly turning a knob and listening for a 
peak receive signal after which he then makes small adjustments to fine tune and to achieve the lowest SWR. 
Because of AGC action, if you were to initially tune slowly, you might never notice the increased noise level 
indicating a peak signal. Tuning with a remote controller is different. The operator sets the tuning rate and then 
pushes either the up (red) or down (green) buttons to tune.  Initially the tuning rate should be set fast to detect 
a peak, after which the tuning rate is lowered to fine tune for best SWR. This takes a little practice at first. The 
benefit is that your hand will not affect the tuning capacitor, and you can do this remotely without touching the 
MLA itself. 

Содержание PreciseLOOP HG-1 Deluxe

Страница 1: ...s the lower and the top section and the top section contains the induction loop All it takes is slight pressure to fit the mast sections securely together Attach the optional tripod adaptor to the ant...

Страница 2: ...are a common HG 2 Controller This controller provides unique indications of CCW CW limits depending on the remote used Each will be explained below THE HG 1 REMOTE TUNER retrofit The HG 1 REMOTE TUNER...

Страница 3: ...tuner case back ADJUST THE TORQUES SENSOR AND REPLACING THE BATTERY applies the HG 1 REMOTE TUNER retrofit only The red LED limit indicator illuminates when the capacitor has reached the CW and CCW p...

Страница 4: ...rn the HG 1 Remote Controller to SBY on and set the Rate control to Max 3 Note Applies to HG 1 Remote only There are no limit switches on the Remote tuner The HG 2 Controller samples the motor current...

Страница 5: ...CW it has the lowest controller QRM noise 4 Note Applies to HG 1 WR REMOTE LOOP TUNER The HG 1 WR uses limit switches So current sampling is used to indicate the motor is powered on CW and CCW limits...

Страница 6: ...will fit securely Tuning is done with the main resonating tuning capacitor as in 40 10 meter operation DIFFERENCES BETWEEN MANUAL AND REMOTE TUNING When tuning manually the operator tunes for a peak...

Страница 7: ...7 SeeTuning the HG 1 WR Loop https www youtube com watch v aGlsGHuvUzI feature youtu be...

Отзывы: