Precaster CX80 Скачать руководство пользователя страница 4

Single Measurement Mode

1. Move the laser dot onto the target.
2. Keep your position stable and click                          .
3. The measurement will be displayed on LCD Screen and laser will be turn off.
4. Click                          again to enable the laser dot for next measurement.

Continuous Measurement Mode

1. Continuous Measurement is also called tracking measurement and is recommend to use for seeking proper 
distance.
2. Move the laser dot onto the target.
3. Keep your position stable and tap and hold                          , the laser distance meter will enter continuous 
measurement mode.
4. Move the device back and forward to proper distance.
5. Click                        to pause the measurement.
6. Click              again to leave the continuously measurement mode.

. Battery Installation & Power Status

1. This unit is powered by 2 x AAA Batteries.
2. Remove battery lid and observing correct polarity before install batteries.
3. Battery level is showed on screen with batty icon on screen              .
4. When the icon              appears, there are approximately 1000 times to measure.
5. Replace batteries when low battery icon              flash on screen.
6. To change new batteries, when install new batteries, then close back lid.

. Switch On and Off

1. Be sure to check battery status before start.
2. Click the                          or             to turn on the device.
3. The device will process the initial procedure and get ready to measure by turn on the laser dot.
4. Tap and hold            for 2 seconds to turn off.
5. The device will turn off automatically after 180 seconds.

. Distance Measurement

NEW BENCHMARK OF MEASURING

3

Содержание CX80

Страница 1: ...LASER DISTANCE METER CX80 Operation Manual NEW BENCHMARK OF MEASURING www precaster com tw CX80 Operation Manual...

Страница 2: ...continuous output of the beams never exceeds 1 0 milli watts 6 Product complies with EMC Test according to EN61000 6 3 2001 A11 2004 EN61000 6 1 2001 EN61326 1 2013 IEC 61326 2012 and FCC Test accordi...

Страница 3: ...indow Laser Receiving Window Clear Power Overview for Screen 1 Laser Indicator 2 Indirect Measuring 3 Measuring Function 4 Measuring Reference 5 Add and Subtract 6 Maxmum Display 7 Minimum Display 8 S...

Страница 4: ...k again to leave the continuously measurement mode Battery Installation Power Status 1 This unit is powered by 2 x AAA Batteries 2 Remove battery lid and observing correct polarity before install batt...

Страница 5: ...LENGTH 4 After finish all the instructions the result AREA will be showed on screen Measurement Reference 1 There are four reference positions for measurement They are back of the unit front of the u...

Страница 6: ...GHT will be showed on screen 4 Stack Out Measurement Stack out measurement help users to split a long distance into several piece equally The function need to be used in Continuous Measurement Mode wi...

Страница 7: ...ed measurements press and hold to enter the lookup mode 3 Press to move the index up and Press to move index down 4 To clear all stored measurements press and hold again in lookup mode to clear all me...

Страница 8: ...rong Check and verify values and steps are correct Install a new battery Measure in an environment within specified working temperature Measure in a darker place shadow target Select a better surface...