Technical Manual for the Installer

Attention!! Before installing, carefully read this manual

.

N.B.

- Stateurop declines every responsib ility in case of not observance of the normative in force in

the Country where the installation is made

The CE mark conforms to the European directive R&TTE 99/05CE

UNIK1E

CONTROL UNIT FOR ONE MOTOR

12VDC

Содержание UNIK1E

Страница 1: ...efully read this manual N B Stateurop declines every responsib ility in case of not observance of the normative in force in the Country where the installation is made The CE mark conforms to the European directive R TTE 99 05CE UNIK1E CONTROL UNIT FOR ONE MOTOR 12VDC ...

Страница 2: ...RNING ROUTINE 7 7 RADIOTRANSMITTERS PROGRAMMING AND ERASING 8 8 SAFETIES AND OPERATING LOGIC 9 9 CONTROL UNIT OPERATION 9 Turning ON 9 Automatic operation 9 Step by step operation 9 Pedestrian opening 9 Obstacle detection 10 Flashing warning light 10 Quick closing after photocell triggering 10 Slow down 10 Emergency battery 10 10 PROGRAMMING BY GTSYSTEM 10 11 TROUBLESHOOTING 11 SAFETY WARNINGS 12 ...

Страница 3: ... self learning routines for acquisition of running and slow down times and of the presence of safeties 50 100 force adjustment via trimmer Motor speed adjustment 0 to 60 stand by time adjustment via trimmer 0 1 to 3 0 obstacle detection triggering time adjustment via trimmer Customisable partial opening for pedestrian transit 12V 15W electric lock expansion optional ELU Courtesy light expansion op...

Страница 4: ...d Standards Fit on the fairleads provided and route the cable making sure to keep power lines separate from control ones Connect power and control lines according to the diagram and instructions given below Make sure that all terminal board inputs are correctly connected and operative GTSYSTEM ELU Electro lock expansion Radio Antenna P1 SET learning key 10A battery fuse Battery Motor Controls Phot...

Страница 5: ...halfway opening for the pedestrian opening b disabling of remote pedestrian opening 1 The control unit checks for the presence of safeties 2 The control unit performs a three second pre opening operation at the force set via the trimmer As this operation is underway check that a gate is actually opening otherwise RESET the control unit and switch over motor lead polarities b upon completion of the...

Страница 6: ... end of run or stop Yellow LED goes off Press the P1 SET key within 5 seconds End of self learning routine JUMPER CH RADIO Channel 1 Channel 2 Radio channel Selection JUMPER TEST Disabled Enabled Safeties test Selection FOR Force PAU Pause OBS Obstacle Detect Sens Minimum force Auto Funct with fast closing Obs detect triggering time 0 1 Medium force Auto Funct with 3 60 pause Obs detect triggering...

Страница 7: ... after four minutes 6 The subsequent RADIO or manual command causes the control unit to perform a full closing operation After three minutes of being left idle the control unit in any case performs the operation automatically If operator controlled closing is selected program photocell Operating Logic via Radio or Manually proceeding as follows a press transmitter CHANNEL 1 key or the P1 SET key o...

Страница 8: ...y until the red LED starts rapidly blinking after about three seconds Press the P2 RADIO key again within six seconds to confirm deletion Deletion is indicated by LED blinking more rapidly 7 3 AUTHORISATION OF NEW REMOTE ROLLING CODE TRANSMITTERS An already authorised transmitter is required to authorise a new one without having to act on the receiver Press and release the learning key accessible ...

Страница 9: ...rating parameters Under such conditions no operation may be performed until the unit is programmed all over again or the EEPROM card replaced 9 2 AUTOMATIC OPERATION Set the PAU trimmer cursor to an intermediate position between 0 and the second last notch according to desired pause time to program automatic mode A radio command or one given via the STR input causes the control unit to pre blink f...

Страница 10: ...enabled by rotating the Pause trimmer anticlockwise in which case the control unit will a resume and complete opening if interrupted during this operation and then automatically close again after one second b automatically re close after one second in case of the photocell having triggered during pause with access open c fully open the gate closing it again after one second if interrupted during c...

Страница 11: ...morize the remote control in the unit or replace the battery The gate starts but then stops The power of the motor is not sufficient or the sensitivity of the obstacle detection is too high Adjust setting of trimmers FOR Force or OBS Obstacle detection There is an obstacle in front of the wings the hinges are jammed or the stirrups of anchorage of the motor is disconnected Eliminate the obstacle f...

Страница 12: ...by the manufacturer and by current law All installation maintenance repair and cleaning operations must be documented The user must store all such documentation and make it available to competent personnel WARNING FOR THE USER Carefully read the enclosed instructions and documentation This product must be used for its intended purpose only Any other use is improper and therefore dangerous The info...