INTENDED USE

PRINCIPLE OF WORK

The basis of the technical solution for recuperation ventilation is the countercurrent, with a 

continuous thermal cycle, a copper heat exchanger, which makes it possible to form two 

different-directed airfl ows in the volume of one cylinder (Fig. 1).
Warm exhaust air that is removed from the room, passing through a copper heat exchanger 

transmits its warmth to the counter stream of fresh air from the outside.
The system allows recover heat, which contributes to increasing the overall recuprration rate 

and allows maintain the optimum humidity mode in the room. Taking into account that air 

streams are separated and regulated at levels “infl ow” – “exhaust”», there is no mixing of 

different-directional air fl ows.
High  velocity  of  the  fl ow  with  suffi cient  heat  transfer  effi ciency  ensures  removal  of  up  to 

90%  moisture  in  a  dispersed  state,  preventing  its  condensation  and  freezing  of  the  heat 

exchanger at low ambient temperatures.

DESCRIPTION OF THE SYSTEM

Ventilation systems “PRANA-150”, “PRANA-200C”, “PRANA-200G” are intended for creation 

and maintenance of healthy microclimate in premises.
These  systems  are  recommended  for  use  in  residential  and  public  facilities  (apartments, 

houses, offi ce premises, educational establishments, kindergartens, etc.).

Monoblocks of the centralized anti-current infl ow-exhaust ventilation.
PRANA-150  and  PRANA-200  belong  to  the  category  of  innovative  and  reliable  products 

aimed at creating and maintaining a healthy microclimate in premises of various functional 

purposes.
High energy effi ciency and signifi cant air exchange capabilities make it possible to apply 

these ventilation systems for organizing domestic ventilation.
Technologically,  the  system  is  a  monoblock  with  high-effi ciency  counter-current 

copperrecuperator ready to use in accordance with the design and assembly tasks and 

conditions.

Fig.1. The principle of operation of recuperator PRANA-150, PRANA-200C, PRANA-200G

Cold fresh air

from outside

100-150 mm

from the ceiling

Removal of warm return

air from the premises

Supply & exhaust are

operating simultaneously

copper

heat exchanger

Preheated fresh air

from outside

Unit slope

3-5 degrees

Removal of the air

from the premises

Содержание 150

Страница 1: ...1 TECHNICAL OPERATING DOCUMENTATION Inflow and exhaust ventilation system with heat recovery PRANA 150 PRANA 200C PRANA 200G 8 ...

Страница 2: ...tems PRANA 150 PRANA 200C PRANA 200G are intended for creation and maintenance of healthy microclimate in premises These systems are recommended for use in residential and public facilities apartments houses office premises educational establishments kindergartens etc Monoblocks of the centralized anti current inflow exhaust ventilation PRANA 150 and PRANA 200 belong to the category of innovative an...

Страница 3: ...t the minus temperature from the outside the use of the Winter Mode is mandatory MAIN TECHNICAL CHARACTERISTICS PRANA 150 PRANA 200G PRANA 200C Diameter of the working module mm with thermal insulation mm 150 160 200 210 200 210 Diameter of the mounting hole mm Length of the working module mm 162 475 215 440 215 500 Recommended area of the premises m 2 60 60 120 Amounts of air exchange during reco...

Страница 4: ... the movement of uncontrolled airflows through the recuperator due to the difference in pressure and temperature inside and outside the premises It is allowed to use when the difference between outside and inside temperatures is no more than 5 o C Defrosting WARNING In the cold season the improper operation of the recuperator is likely to freeze it When freezing it is necessary to activate function...

Страница 5: ... and the dimensions of ventilation system PRANA 150 PRANA 200G PRANA 200C a the ventilation grid and air intake in the premises b monoblock side view c the ventilation grid and air intake from the outside 535 475 35mm 500mm 475 a a a a b b b b c c c c ...

Страница 6: ...he normal operation of the system it is necessary that its body facing the the outside extends beyond the wall by 1 2 cm to the beginning of the air intake Fig 4 INSTALATION Fig 4 The diagram of installing the recuperator in the wall airborne airborne grille grille airborne grille airborne airborne grille airborne 50 mm 50 mm unit slope unit slope 3 5 degrees 3 5 degrees unit slope 3 5 degrees uni...

Страница 7: ...n laid to the mounting hole then the power supply to the working module cable is carried out in the immediate vicinity of the body of the recuperator Shorten the electric cable from the recuperator to a length that is convenient for electrical connection All electrical cables used in the installation should have the cross section of 0 5 0 75 mm The operation of the system is controlled using a rem...

Страница 8: ...he graphic symbols of the indication correct operation of the device in accordance with the control devices The device must be switched off in case of excessive oscillations and noise damage to the elements of the device body damage to the insulation of the electric cable damage to the elements of automation the temperature of the outside air is below 30 ºС 1 The lid is closed Do not switch on the...

Страница 9: ...commended 1 2 times a year and preventive inspection of surfaces of the fans and the heat exchanger and if necessary in cleaning them The procedure for disassembling assembling the device for after cleaning 6 Unscrew the self tapping screws through special openings Remove the flange 7 Extract the heat exchanger and fans from the body 3 Open the lid of the recuperator 4 Turn the fasteners of the lid...

Страница 10: ...and be below during the installation 14 The flange must be installed correctly the larger protrusion of the should be below 11 Clean the heat exchanger in adry or if necessary in a wet manner WARNING Before rinsing or wet cleaning of the heat exchanger make sure that all the electrical components and parts are removed from the heat exchanger except for the components of heating with minimally raise...

Страница 11: ...enance are carried out only after the device is disconnected from the electrical supply network WARNING Do not operate the ventilation system if there is a threat that foreign objects may enter the inflow part of the body which objects may jam or damage the impeller of any of the two fans WARNING Do not operate the ventilation system in premises where the air contains aggressive substances and does...

Страница 12: ...12 ...

Отзывы: