INTENDED USE

PRINCIPLE OF WORK

The basis of the technical solution for recuperation ventilation is the countercurrent, with a 

continuous thermal cycle, a copper heat exchanger, which makes it possible to form two 

different-directed airfl ows in the volume of one cylinder (Fig. 1).

Warm exhaust air that is removed from the room, passing through a copper heat exchanger 

transmits its warmth to the counter stream of fresh air from the outside.

The system allows recover heat, which contributes to increasing the overall recuprration rate 

and allows maintain the optimum humidity mode in the room. Taking into account that air 

streams are separated and regulated at levels “infl ow” – “exhaust”», there is no mixing of 

different-directional air fl ows.
High  velocity  of  the  fl ow  with  suffi cient  heat  transfer  effi ciency  ensures  removal  of  up  to 

90% moisture in a dispersed state, preventing its condensation and freezing of the heat 

exchanger at low ambient temperatures.

DESCRIPTION OF THE DEVICE

Ventilation units “PRANA-150”, “PRANA-200C”, “PRANA-200G” are intended for creation and 

maintenance of healthy microclimate in premises.
These  systems  are  recommended  for  use  in  residential  and  public  facilities  (apartments, 

houses, offi ce premises, educational establishments, kindergartens, etc.).

PRANA-150  and  PRANA-200  belong  to  the  category  of  innovative  and  reliable  products 

aimed at creating and maintaining a healthy microclimate in premises of various functional 

purposes.
High energy effi ciency and signifi cant air exchange capabilities make it possible to apply 

these ventilation units for organizing domestic ventilation.
Technologically,  the  system  is  a  monoblock  with  high-effi ciency  counter-current  copper 

recuperator ready to use in accordance with the design and assembly tasks and conditions.

Fig.1. The principle of work of recuperator PRANA-150, PRANA-200C, PRANA-200G

Cold fresh air

from outside

100-150 mm

from the ceiling

Removal of warm exhaust air

from the premises

Inflow & exhaust are

operating simultaneously

with no air flows mixing

Copper

heat exchanger

Preheated fresh air

from outside

Unit slope

3-5 degrees

Removal of exhaust air

from the premises

Содержание 150 ERP LITE

Страница 1: ...1 8 TECHNICAL OPERATING DOCUMENTATION Bidirectional unit with heat recovery PRANA 150 ERP LITE PRANA 200C ERP LITE PRANA 200G ERP LITE ...

Страница 2: ...E DEVICE Ventilation units PRANA 150 PRANA 200C PRANA 200G are intended for creation and maintenance of healthy microclimate in premises These systems are recommended for use in residential and public facilities apartments houses office premises educational establishments kindergartens etc PRANA 150 and PRANA 200 belong to the category of innovative and reliable products aimed at creating and maint...

Страница 3: ... Mode is mandatory TECHNICAL DATA PRANA 150 PRANA 200G PRANA 200C Diameter of the working module mm with thermal insulation mm 150 160 200 210 200 210 Diameter of the mounting hole mm Length of the working module mm 162 475 215 440 215 500 Recommended area of the premises m 2 60 60 120 Amounts of air exchange during recovery m3 h the inflow and exhaust work simultaneously inflow exhaust night minima...

Страница 4: ... and switched off motors It lies in the movement of uncontrolled airfl ows through the recuperator due to the difference in pressure and temperature inside and outside the premises It is allowed to use when the difference between outside and inside temperatures is no more than 5 o C Defrosting WARNING In the cold season the improper operation of the recuperator is likely to freeze it When freezing ...

Страница 5: ... and the dimensions of ventilation units PRANA 150 PRANA 200G PRANA 200C a the ventilation grid and air intake in the premises b monoblock side view c the ventilation grid and air intake from the outside 535 475 35mm 500mm 475 a a a a b b b b c c c c ...

Страница 6: ...nstallation will be carried out In order to ensure the normal operation of the system it is necessary that its body facing the the outside extends beyond the wall by 1 2 cm to the beginning of the air intake Fig 4 INSTALATION Fig 4 The diagram of installing the recuperator in the wall air intake sealant airborne airborne grid grid sealan 50 mm 50 mm unit slope unit slope 3 5 degrees 3 5 degrees se...

Страница 7: ...ator Shorten the electric cable from the recuperator to a length that is convenient for electrical connection All electrical cables used in the installation should have the cross section of 0 5 0 75 mm The operation of the system is controlled using a remote control or mobile application that controls the operation of the fans installed in the body of the ventilation system it turns on regulates a...

Страница 8: ...he graphic symbols of the indication correct operation of the device in accordance with the control devices The device must be turned off in case of excessive oscillations and noise damage to the elements of the device body damage to the insulation of the electric cable damage to the elements of automation the temperature of the outside air is below 30 ºС 1 The lid is closed Do not tunr on the dev...

Страница 9: ...screws through special openings Remove the flange 6 Turn the mounting locks of the front cover MAINTENANCE The maintenance consists in periodic recommended 1 2 times a year and preventive inspection of surfaces of the fans and the heat exchanger and if necessary in cleaning them The procedure for disassembling assembling the device for after cleaning 10 Remove the blades from the fan housings and c...

Страница 10: ...temperature from 20 С to 40 С TRANSPORTATION AND STORAGE RULES 12 The drain in the heat exchanger and the body must coincide and be below during the installation 13 The heating of the condensate drainage the heating element must be located beneath near the hole in the housing 14 The flange must be installed correctly the larger protrusion of the should be below 11 Clean the heat exchanger in adry o...

Страница 11: ...ed out only after the device is disconnected from the electrical supply network WARNING Do not operate the ventilation unit if there is a threat that foreign objects may enter the inflow part of the body which objects may jam or damage the impeller of any of the two fans WARNING Do not operate the ventilation unit in premises where the air contains aggressive substances and does not correspond to t...

Страница 12: ...12 ...

Отзывы: