SAFTEY INSTRUCTIONS  

 

2.1     General information  
 

Before performing any actions detailed within this instruction, the Site Health and Safety instructions 
must read and fully understood.  
Whenever the equipment is operated, maintained or used in anyway, the procedures detailed within 
the Health and Safety Dossier (DHS) and any procedures detailed within these instructions shall be 
followed. 
The pump supplied has been designed with safety in mind, where as hazards cannot be eliminated; 
the risk has been minimized by the use of guards and other design features. Some hazards cannot be 
guarded against and the instructions below MUST BE COMPLIED WITH for safe operation. These 
instructions cannot cover all circumstances. It is the responsibility of the user of the equipment for 
maintaining safe working practices at all times. 
 

 

Before starting work, become familiar with the control devices and their functions. 

 

Do not subject the equipment to work, it could not be a reasonably support. 

 

Access to the equipment should be restricted to the personnel responsible for installation, 
operation and maintenance and they must be trained, only authorize and skilled labor from 
Prakash service center should handle their respective tasks. 

 

The plates concerning safety must be very clear. 

 

Handel the motor pumps carefully. 

 

When handling the motor pump use suitable lifting equipment with safety regulation and 
wear safety shoes and gloves. 

 

Use suitable cables of allowable length, marked with suitable cross-sections. 

 

Protect the cable from high temperatures, lubricants and sharp corners, as this may result in 
puncture of cables and case damage to the equipment and life. 

 

Never run the set dry as it may reduce the life of the equipment or damage. 

 

During the installation operations, pay attention to hanging loads and follow the 
corresponding safety rules. 

 

Make sure the control panel and the electrical system in accordance with current regulation. 

 

Do not tamper to remove the pump’s guards. 

 

Operation of the equipment for the application other than for which it is supplied can 
increase the risk from hazards. Please consult Prakash pump skilled engineer before making 
such change in the application of the equipment. 

 

Improper installation, operation and maintenance of the product supplied could result in 
injury or death. 

 

Within the manual, safety instructions are marked with safety symbols. 

 
 
 
 
 
 
 
 

 

Содержание SP-M8A-10

Страница 1: ...Installation Maintenance and Operation manual 4 Stainless steel submersible pump Type SP R5A SP M8A Series...

Страница 2: ...y that pump supplied by us is free from defective material and faulty workmanship This warranty holds one time repair service free of charge Warranty excluding all liability for direct or indirect dam...

Страница 3: ...Prakash pump Copyright 2016 Contents 1 GENERAL 2 SAFTEY INSTRUCTIONS 3 TECHNICAL DATA 4 FUNCTION AND FEATURE 5 INSTALLATION 6 GENERAL LAYOUT 7 CONDITION OF USAGE 8 MAINTENANCE 9 FAULT AND SOLUTIONS 10...

Страница 4: ...following models of submersible pump Radial Flow SP R5A Mixed Flow SP M8A Pump model SP R5A 8 SP R5A 12 SP R5A 17 SP R5A 21 SP R5A 25 SP R5A 33 SP R5A 38 SP R5A 44 SP R5A 52 SP R5A 60 SP R5A 75 SP R5A...

Страница 5: ...ry so as to ensure the performance and features given in our catalogues Regular operation of the equipment depends on its being used correctly and serviced periodically or regularly by our authorized...

Страница 6: ...for installation operation and maintenance and they must be trained only authorize and skilled labor from Prakash service center should handle their respective tasks The plates concerning safety must...

Страница 7: ...5A 75 75 7 5 10 0 117 480 SP R5A 85 85 7 5 10 0 117 544 Note Recommended motor SM150 Motors are available both in single phase and three phases except the pump below 3 Hp Mixed Flow SP M8A Model Numbe...

Страница 8: ...eration must be carried out by suitable trained and qualified personnel only Pump installation Before installation must check whether the cable is damaged scratched broken etc If they are faulty must...

Страница 9: ...ulation sheathes or other system used for submerged cables The operating temperature limiting the drop in voltage to at most 3 The live wire should made dead before making the connection The connectio...

Страница 10: ...department Prakash pump Copyright 2016 6 GENERAL LAYOUT Control panel or starter Pump Outlet pipe Cable Well Float switches Bracket Main Line Discharge pipe Preliminary drawing only not to be scale G...

Страница 11: ...rder to avoid the risk of blocking Run the pump at a sequence time as recommended 9 FAULT AND SOLUTIONS FAULT POSSIBLE CAUSES REMEDIES Pump does not start Too low voltage Impeller blocked Stator windi...

Страница 12: ...ad grounding or lightening strikes of pump Check power supply replace fuse Shut off power clean obstacles Repair must consult the dealer and technician qualified 10 SPARE PARTS In the condition of req...

Страница 13: ...ail info prakashpump com www prakashpump com UAE 00971 50 6731283 00971 37222733 Oman 00968 95690021 00968 26883982 The Company reserves the rights to modify the technical specification and instructio...

Отзывы: