www.praherplastics.com
14
16 Troubleshooting
The drive rotates continually without approaching a position
o
Device was driven without matching valve
Please return for repair; damage has already occurred in this case
The disk is not lifting freely, or the drive is not running smoothly, or flow noises
can be heard
o
The pump does not switch off on lifting the valve disk
The pump must always be switched of before lifting the valve disc
o
The drop from the water surface to the valve is too great
Make sure that the total water column does not exceed 3m.
o
The V6 valve is soiled or clogged by foreign matter
Clean the valve and use a pre-filter
The drive rotates in wrong direction
o
More than one positions are triggered
You have to take care that only one Position is triggered