LED INDICATION 

 

On 

DMX signal OK

 

Off 

No DMX signal

 

Green

 

Flash 

DMX signal error

 

Yellow On 

Setting the panel

 

Blue On 

Power 

Red 

Slave mode or Running self test mode

 

Red/Green 

Green 

Master mode 

 

MAINTENANCE 

 

To prolong the life of the projector, some maintenance work has to be done to ensure the LED optical system in good 
condition. If the projector does not function, check the fuses on the power socket of the projector, they should only be 
replaced by fuses of the same specification. Should these be damaged, call a qualified technician before replacement. 
The projector has thermal protection device that will switch off the projector in case of overheating.Should either of these 
operate, check that the fans are not blocked, and if they are dirty, clean them before switching on the projector again. 
Check that the fans are operational, if not, call a qualified technician. 

Any maintenance work should only be carried out by qualified technicians. 

 

KEEPING THE PROJECTOR CLEAN 

 

To ensure the reliability of the projector, it should be kept clean. It is recommended that the fans should be cleaned 
every 15 days. LED lens should also be regularly cleaned to maintain an optimum light output.   

Cleaning frequency depends on the environment in which the fixture operates: damp, smoke or particularly dirty 
surroundings can cause greater accumulation of dirt on the unit’s optics. A soft cloth and typical glass cleaning products 
should be used for cleaning. It is recommended to clean the external optics at least once every 20 days. 

 
Do not use any organic solvent, e.g. alcohol, to clean housing of the apparatus. 
 

 

TROUBLESHOOTING 

 

PROBLEM ACTION 

The projector doesn’t switch on 

¾

  Check the fuse on the power socket. 

The lamp comes on but the projector 
doesn’t respond to the controller 

¾

  Make sure that the projector is correctly configurated. 

¾

  Replace or repair the DMX cable. 

The beam appears dim 

¾

  Check that the optics is clean. 

Содержание XLED 590PR-8100

Страница 1: ...l contains important information about the safe installation and use of this projector Please read and follow these instructions carefully and keep this manual in a safe place for future reference PR LIGHTING LTD http www pr lighting com ...

Страница 2: ...on of this manual we reserve the right to change specifications in the course of product improvement The publishers cannot be held responsible for the accuracy of the information herein or any consequence arising from them Every unit is tested completely and packed properly by the manufacturer Please make sure the packing and or the unit are in good condition before installation and use Should the...

Страница 3: ...r supply match the power requirements of the projector It is essential that each projector is correctly earthed and that electrical installation conforms to all relevant standards Do not connect this device to any other types of dimmer apparatus Make sure that the power cord is never crimped or damaged by sharp edges Never let the power cordcomeintocontact withothercables Only handle the power cor...

Страница 4: ...ight of XLED 590 WARNING 1 The projector MUST NOT be lifted or carried by the clamps 2 For safety reasons the safety cord should afford 10 times of the unit s weight POWER SUPPLY MAINS Connect the power cord as follows L live brown E earth yellow green N neutral blue Use the plug provided to connect the mains power to the projector paying attention to the voltage and frequency marked on the panel ...

Страница 5: ... last fixture s output to a DMX terminator as shown in the figure below DMX IN DMX OUT DMX IN DMX OUT DMX IN DMX IN FROM CONTROLLER TERMINATER DMX TERMINATOR In the Controller mode at the last fixture in the chain the DMX output has to be connected with a DMX terminator This prevents electrical noise from disturbing and corrupting the DMX control signals The DMX terminator is simply an XLR connect...

Страница 6: ...f you stay for minutes it will show display status automatically TO SET THE DMX STARTADDRESS Each XLED 590 must be given a DMX start address so that the correct projector responds to the correct control signals This DMX start address is the channel number from which the projector starts to listen to the digital control information being sent out from the controller The XLED 590 has 3 DMX modes whi...

Страница 7: ...PR LIGHTING When DMX is Lost Hold Last Value PR LIGHTING Pan DMX Invert OFF PR LIGHTING Pan DMX Invert PR LIGHTING Pan DMX Invert ON PR LIGHTING Tilt DMX Invert OFF PR LIGHTING Tilt DMX Invert PR LIGHTING Tilt DMX Invert ON PR LIGHTING Pan Tilt Swap OFF PR LIGHTING Pan Tilt Swap PR LIGHTING Pan Tilt Swap ON PR LIGHTING Dimmer Invert OFF PR LIGHTING Dimmer Invert PR LIGHTING Dimmer Invert ON PR LIG...

Страница 8: ... XX PR LIGHTING Software Version PR LIGHTING Display Board PR LIGHTING Display Board PR LIGHTING View DMX Values PR LIGHTING DMX Channel XXX XXX PR LIGHTING Information PR LIGHTING Electronic SN PR LIGHTING Electronic SN PR LIGHTING Factory Setup OFF PR LIGHTING Calibration Menu Red PR LIGHTING Calibration Menu Red XX PR LIGHTING Calibration Menu Green PR LIGHTING Calibration Menu Green XX PR LIGH...

Страница 9: ... Memory User Memory 2 PR LIGHTING Select Memory Preset Memory 1 PR LIGHTING Select Memory Preset Memory 2 PR LIGHTING Operation Mode Slave Mode PR LIGHTING Select Memory Preset Memory 3 PR LIGHTING Operation Mode PR LIGHTING Operation Mode Static Scene PR LIGHTING Dimmer PR LIGHTING Dimmer XXX PR LIGHTING Color Temp PR LIGHTING Color Temp XXX PR LIGHTING RGB Macros PR LIGHTING RGB Macros XXX PR LI...

Страница 10: ... LIGHTING Dimmer XXX PR LIGHTING Color Temp PR LIGHTING Color Temp XXX PR LIGHTING RGB Macros PR LIGHTING RGB Macros XXX PR LIGHTING Red PR LIGHTING Red XXX PR LIGHTING Green PR LIGHTING Green XXX PR LIGHTING Blue PR LIGHTING Blue XXX PR LIGHTING Strobe PR LIGHTING Strobe XXX PR LIGHTING Pan Coarse PR LIGHTING Pan Coarse XXX PR LIGHTING Pan Fine PR LIGHTING Pan Fine XXX PR LIGHTING Tilt Coarse PR ...

Страница 11: ...TING Strobe PR LIGHTING Strobe XXX PR LIGHTING Pan Coarse PR LIGHTING Pan Coarse XXX PR LIGHTING Pan Fine PR LIGHTING Pan Fine XXX PR LIGHTING Tilt Coarse PR LIGHTING Tilt Coarse XXX PR LIGHTING Tilt Fine PR LIGHTING Tilt Fine XXX PR LIGHTING Static Scene PR LIGHTING M Speed PR LIGHTING M Speed XXX PR LIGHTING Reset User Memory 1 PR LIGHTING Reset User 1 Unlock 2 3 4 Press buttons UP DOWN and ENTE...

Страница 12: ...r 113 120 Orange 121 128 Pink 3 4 Macro Channel 129 255 RGB Color Cycle 2 4 5 RED 000 255 Red dimming from dark to light 6 RED 16Bit 000 255 Red in 16 Bit precision 3 5 7 GREEN 000 255 Green dimming from dark to light 8 GREEN 16Bit 000 255 Green in 16 Bit precision 4 6 9 BLUE 000 255 Blue dimming from dark to light 10 BLUE 16Bit 000 255 Blue in 16 Bit precision 000 009 No strobe 5 7 11 Strobe 010 ...

Страница 13: ... qualified technician Any maintenance work should only be carried out by qualified technicians KEEPING THE PROJECTOR CLEAN To ensure the reliability of the projector it should be kept clean It is recommended that the fans should be cleaned every 15 days LED lens should also be regularly cleaned to maintain an optimum light output Cleaning frequency depends on the environment in which the fixture o...

Страница 14: ... DIMMER 0 100 linearly adjustable STROBE 1 25 F P S HEAD MOVEMENT Pan 540º Tilt 270º with auto position correction BEAMANGLE Projector beam angle 26 Options 10 35 Note Projector specifications are subject to change according to different projector beam angles CONTROL DMX512 5 pin interfaces RDM control protocol 8 channels in short mode 13 channels in standard mode and 17 channels in extended mode ...

Страница 15: ...tic die casting aluminum IP20 WORK ENVIRONMENT TEMPERATURE 20 C 40 C WEIGHT 11kg SIZES See it below 350 350 249 353 243 267 LIGHT OUTPUT DIAMETER m DISTANCE m 5m 6m 5m 6m 7m 4m 2m 4m 2m 0m 1m 1m 3m 3m 7m 0m 5m 10m 15m 20m 25m 30m 26 2 27 4 55 6 82 9 09 11 36 13 64 0 26 lux 6079 1520 675 380 243 169 26 lux 1030 257 114 64 41 29 26 lux 3301 825 367 206 132 92 26 lux 2515 629 279 157 101 70 B R G B R...

Страница 16: ...ree PAN A B C D A B C D V S G Fuse VCC GND PWM V G TXD RXD V G A IN2 A IN1 DMX 1 2 3 4 5 1 2 3 4 5 DMX IN DMX OUT M1 M2 M3 J1 J2 J3 V G S2 S1 VCC GND PWM V G S V B G R R G B V POWER GND R G B ANODE POWER SW V G S2 S1 POWER PCB LED DRIVE PCB LED PCB MAIN PCB Box Fan Head Fan GND 24V PR 8100 006 T Input Head ...

Страница 17: ...FAN IN LAMP HEAD 030060061 1 DC24V 0 22A LENS 070070006 90 LED 150020201 30 Red LED 150020202 30 Green LED 150020204 30 Dark blue POWER STWITCH 190010104 1 AC250V 10A POWER SUPPLY 192010130 1 DC24V 2A LED CONTROL PCB 230020400 1 LED DRIVE PCB 230020402 1 FUSE 270041006 1 5X20 10A PAN DRIVE BELT 290151256 1 HTD330 3M TILT DRIVE BELT 290151223 1 HTD426 3M 8 ...

Страница 18: ...18 18 PR LIGHTING LTD PR New Hi tech Science Park 1582 XingyeAvenue Nancun Panyu Guangzhou 511442 China TEL 86 20 3995 2888 FAX 86 20 3995 2330 P N 320050005 Last Revision 20090324 ...

Отзывы: