INSTALL THE PROJECTOR 

 

 

 

When the projector is used, as the right figure above, unfold the support to certain angle and put the projector onto a 

flat surface. Make sure it is steady. 

When the projector is used at a high place, as the left figure above, fold the support, turn it round to the top of the 

projector, connect a lamp hook to the mounting hole reserved in the support by screws, and then hang the hook to a high 
place. Eventually, use the safety cord provided to pass through the handles and hang it as a second safety fixing. 
 

CONTROL SYSTEM AND POWER CONNECTION 

 

 

 

Connection  between  the  controller  and  a  projector  and  between  one  projector  and  another  must  be made  with  a  2 
core-screened cable, with each core having at least a 0.5mm diameter. Please use the projector’s cannon 3- pin signal 
input and output cables as connection. The 3-pin signal connections are connected as shown in the figure above.   
Note: Care should be taken to ensure that none of the pins touch the metallic body of the plug or each other. The body of 
the plug is not connected in any way. The XPar 360 accepts digital control signals in protocol DMX512 (1990).   
 
The amount of projectors connected in parallel is not more than 32. Connect the controller’s output to the first fixture’s 
input cable with a 3-pin signal cable, connect the first fixture’s output cable to the second fixture’s input cable and connect 
the rest fixtures in the same way. Eventually, connect the last fixture’s output cable to a DMX terminator. Note: Only when 
all the start addresses of fixtures are set the same,

 

synchronous control could be achieved. 

When the first fixture is not connected to the controller, and all the other connections are the same as above, it is master / 
slave mode connection. To achieve master / slave mode, set the first fixture master , the others salve( slave is default). 
 
As for power connections, each projector has to be supplied separately by external power. Use the power cord of each 
projector to connect the mains power directly, paying attention to the voltage and frequency marked on the panel of the 
projector.

 

 

Lamp Hook Mounting Hole

Safety Cable

Support

FUNCTION

DMX IN

3

1

1

DMX OUT

3

2

2

3

2

PIN

1

1

GND

DATA +

DATA -

DMX512

Содержание XPar 360 PR-8955

Страница 1: ...contains important information about the safe installation and use of this projector Please read and follow these instructions carefully and keep this manual in a safe place for future reference PR L...

Страница 2: ...manual we reserve the right to change specifications in the course of product improvement The publishers cannot be held responsible for the accuracy of the information herein or any consequence arisi...

Страница 3: ...ll relevant standards Do not connect this device to any other types of dimmer apparatus Make sure that the power cord is never crimped or damaged by sharp edges Never let the power cordcomeintocontact...

Страница 4: ...plug or each other The body of the plug is not connected in any way The XPar 360 acceptsdigital control signals in protocol DMX512 1990 The amount of projectors connected in parallel is not more than...

Страница 5: ...ector and press button ENTER for more than 5 seconds to unlock the panel the LCD will show the function menu of the projector each main menu has its submenus and each submenu has a specific function F...

Страница 6: ...ort mode For example the standard mode has 12 channels so set the No 1 projector s address 001 No 2 projector s address 13 No 3 projector s address 25 No 4 projector s address 37 and so on Launch the...

Страница 7: ...white ALLO Red green blue white mENU Operation mode dmx DMXmode PR XX Preset memory PR01 PR16 ET XX User memory ET01 ET16 COL1 Colour 1 XX Number 0 14 3 COL2 Colour 2 XX Number 0 14 COL3 Colour 3 XX...

Страница 8: ...Red and Blue Purple 192 207 Red Green Blue and White 208 223 Full Power 224 239 Yellow and White 240 255 Amber Blue and White 3 4 5 Amber 000 255 Linear adjustment from dark to light 4 5 6 Red 000 255...

Страница 9: ...4 079 User memory 5 080 095 User memory 6 096 111 User memory 7 112 127 User memory 8 128 143 User memory 9 144 159 User memory 10 160 175 User memory 11 176 191 User memory 12 192 207 User memory 13...

Страница 10: ...hannel priorityfrom high to low is as the following Dimming Preset memory User memory ARGBW dimming HSV dimming Macro channel Color temperature When high priority channel is used low priority channel...

Страница 11: ...the fixture operates Soft cloth and typical glass cleaning products should be used for cleaning with care It is recommended to clean projector at least once every 20 days Do not use any organic solve...

Страница 12: ...ER 0 100 linearly adjustable STROBE Electronic Strobe 0 25F P S LIGHT ANGLE Field Angle 1 10 Maximum 28 Beam Angle 1 2 Maximum 1 2 15 Lens Angle 15 Optional LensAngle 8 25 45 CONTROL DMX512 3 pin inte...

Страница 13: ...NMENT TEMPERATURE 20 C 40 C WEIGHT 3 9kg SIZES LIGHT OUTPUT 321 277 249 226 28 Diameter m Distance m 5m 6m 5m 6m 7m 4m 2m 4m 2m 0m 1m 1m 3m 3m 7m 0m 5m 10m 15m 20m 25m 30m 3 5 8 14 31 124 722 181 80 4...

Страница 14: ...14 17...

Страница 15: ...T ORDER CODES NAME PART NO QUANTITY REMARK LED LENS 070070047 60 15 SIGNALCABLE 230090002 1 3meters POWER SUPPLY 190010119 1 150W58V DRIVER BOARD 230060115 1 LED CONTROLBOARD 230060139 1 LED LAMP BOAR...

Страница 16: ...16 17...