PR Lighting THEATRE COLOUR LT Скачать руководство пользователя страница 5

Theatre Colour LT manual.doc 

5/12 

 
 
 

When connecting power supply, please pay attention to the voltage and frequency marked on the 
panel of the projector. It is recommended that each projector is supplied separately so that they 
may be individually switched on and off. 
Should any other connections be required they  must be carried out with the following 
configuration. 
 
Earth = Green/Yellow cable 
Neutral = Blue cable 
Live = Brown cable 

 
 
 

 
The projector may be operated either in Stand-Alone automatic mode or be controlled via 
standard DMX512 by a controller. With the touch-switches and the digital display screen, DMX 
start address can be easily set and the various setup options may be configured. 
The display shows the DMX start address after the projector is switched on (if you have already 
set the DMX start address and saved it, the screen will display the last setting). 

 

TO SET THE DMX START ADDRESS 

 
Press the  UP or  DOWN buttons and the display will 
show the DMX start address. 
 
Confirm your choice by pressing the  ENTER button, 
this will save and set the DMX start address. 
 
The display will show the latest setting each time the 
projector is powered up. 
 
To control the projector with a DMX controller the 
DMX start address must be set.  
 
Ensure that none of the Stand-Alone options are set or they will interfere with correct DMX 
operation. 

 

SETUP OPTIONS - PROJECTOR CONFIGURATION

 

 
To browse through the various Setup Options, press the FUNC button consecutively. There are 8 
Option codes (1~6 and A, b), and the functions provided are listed in the following table. 
 
Once you have selected the desired operation code, press the key  UP or  DOWN to select “y” 
(means ON) or “no “ (means OFF). N = NO, Y = YES. 
 
Press the key  ENTER to save the selected function and configuration. If the display is showing 
“y”, then the setting has been enabled. In the same way, if it was showing “n” when you pressed 

ENTER the option has been disabled. 

 
The Red LED will flash during this operation. 
 
 

OPERATION AND STAND-ALONE MODE

 

POWER SUPPLY - MAINS

 

Содержание THEATRE COLOUR LT

Страница 1: ...information about the safe installation and use of this projector Please read and follow these instructions carefully and keep this manual in a safe place for future reference PR LIGHTING LTD Yingbin...

Страница 2: ...PCS XLR socket 1 PCS This manual 1 PCS Thank you for purchasing the product Theatre Colour LT PR 3021 This product manual contains important information about the safe installation and use of this pro...

Страница 3: ...mpt to dismantle and or modify the projector in any way Electrical connection must only be carried out by qualified personnel Before installation ensure that the voltage and frequency of power supply...

Страница 4: ...an adjust the screw illustrated to let the Fresenel lens in or out for magnifying lessening the images or soft focusing the beams A B C Loosen the 3 access screws at the rear of the projector and pull...

Страница 5: ...Press the UP or DOWN buttons and the display will show the DMX start address Confirm your choice by pressing the ENTER button this will save and set the DMX start address The display will show the la...

Страница 6: ...e projector and another must be made with 2 core screened cable with each core having at least a 0 5mm diameter Connection to and from the projector is via cannon 3 pin XLR plugs and sockets which are...

Страница 7: ...Colour LT has 9 channels so set the No 1 projector s address 001 No 2 projector s address 004 No 3 projector s address 007 No 4 projector s address 010 and so on Certainly you may use formulation addr...

Страница 8: ...lified technician before replacement The projector has 2 thermal protection devices that will switch off the projector in case of overheating should either of these operate check that the fans are not...

Страница 9: ...roken Remove dust or grease stored on lenses Power supply 230V AC 50Hz Optional 240V 220V 200V 120V 100V AC 50 60Hz Power consumption 1400W at 220V Lamp OSRAM halogen 1200W Working life 200 hours Chan...

Страница 10: ...PCB DISPLAY PCB THERMOSTAT LAMP 230V 1200W SENSOR DIMMER PCB FAN1 FAN2 FAN3 FAN4 COLOUR WHEEL 1 COLOUR WHEEL 2 U1 U2 U5 U4 U3 U6 U7 U10 U9 U8 FUSE 4A 250V U11 U12 LED1 LED2 16 PIN DMX512 INPUT DMX512...

Страница 11: ...1200W MOTOR 1 COLOUR WHEEL 1 MOTOR 2 COLOUR WHEEL 2 030040024 17HS0002 45 SENSOR 171000008 MOC3200 U1 U2 170110001 DRIVER CHIPS U3 230040087 WATCH DOG CHIP U4 170050002 ARITHMETIC AMPLIFIER CHIP U5 2...

Страница 12: ...Theatre Colour LT manual doc 12 12 PR LIGHTING LTD Yingbin Road Dashi Panyu Guangzhou China Post Code 511430 TEL 020 8478 1888 FAX 020 8478 6023 P N 321010056 Last Revision 16 01 2004...

Отзывы: