Theatre Colour LT manual.doc
5/12
When connecting power supply, please pay attention to the voltage and frequency marked on the
panel of the projector. It is recommended that each projector is supplied separately so that they
may be individually switched on and off.
Should any other connections be required they must be carried out with the following
configuration.
Earth = Green/Yellow cable
Neutral = Blue cable
Live = Brown cable
The projector may be operated either in Stand-Alone automatic mode or be controlled via
standard DMX512 by a controller. With the touch-switches and the digital display screen, DMX
start address can be easily set and the various setup options may be configured.
The display shows the DMX start address after the projector is switched on (if you have already
set the DMX start address and saved it, the screen will display the last setting).
TO SET THE DMX START ADDRESS
Press the UP or DOWN buttons and the display will
show the DMX start address.
Confirm your choice by pressing the ENTER button,
this will save and set the DMX start address.
The display will show the latest setting each time the
projector is powered up.
To control the projector with a DMX controller the
DMX start address must be set.
Ensure that none of the Stand-Alone options are set or they will interfere with correct DMX
operation.
SETUP OPTIONS - PROJECTOR CONFIGURATION
To browse through the various Setup Options, press the FUNC button consecutively. There are 8
Option codes (1~6 and A, b), and the functions provided are listed in the following table.
Once you have selected the desired operation code, press the key UP or DOWN to select “y”
(means ON) or “no “ (means OFF). N = NO, Y = YES.
Press the key ENTER to save the selected function and configuration. If the display is showing
“y”, then the setting has been enabled. In the same way, if it was showing “n” when you pressed
ENTER the option has been disabled.
The Red LED will flash during this operation.
OPERATION AND STAND-ALONE MODE
POWER SUPPLY - MAINS