PR Lighting PR-8125 Скачать руководство пользователя страница 13

13/18 

PRODUCT CLEANING 

 

To ensure the reliability of the fixture it should be kept clean. It is recommended that the fans should be cleaned every 15 days. The 
lens should also be regularly cleaned to maintain an optimum light output.

 

Do NOT use any type of solvent containing chemical 

elements. 

 
Cleaning  intervals  depends  on  the  environment  in  which  the  fixture  operates  and  use  frequency.    A  soft  cloth  and  typical  glass 
cleaning products should be used in cleaning the fixtures. It is recommended to clean the external optical system at least once every 20 
days. 

 
Do not use any organic solvent, e.g. alcohol, to clean the housing of the apparatus to avoid damages 
 
 

TROUBLE SHOOTING 

 

PROBLEM 

ACTION 

The fixture can not start   

 

Check if the fuse on the power socket is broken or not . 

 

Check the status of the fuse   

The lamp works normal but the fixture doesn’t 

respond to the controller 

 

Check if the fixture’s start address is set properly 

 

Check if XLR signal cable is broken or not 

The fixture only functions intermittently 

 

Make  sure  the  fans  work  normally  and  if  dirt  blocks  fans  and  fan 

screens. 

The beam appears dim and brightness decreases 

apparently   

 

Check if the lamps reach the end of their lives 

 

Check if external and internal optical systems are clean or not. 

 
 

TECHNICAL DATA

 

 

VOLTAGES: 

100V~240V AC,50/60Hz 

 

LIGHT SOURCE:

 

TYPE: LED 

LZ4-04MDCA

 

QUANTITY: 7 Pcs       

LIFE SPAN: 50,000 Hrs 

 

POWER CONSUMPTION: 

 

200W@220V 

 

HEAD MOVEMENT: 

 

Pan: 72

0°,360°or Endless,    Tilt : 270°or Endless

 

Pan Tilt Swap and Invert Function 

;

 Auto-position correction and magnet positioning function 

 

COLOR SYSTEM: 

RGBW linear color mixing with macro

 

Содержание PR-8125

Страница 1: ...t information about the safe installation and use ofthis product Please read and follow these instructions carefully before installing and using the product and keep this manual in a safe place for fu...

Страница 2: ...Every ex company fixture is tested completely and packed properly by the manufacturer The use explanations and warnings in this manual must be strictly followed Any damage caused by improper use will...

Страница 3: ...conformstoallrelevant standards Donot connect this device toanyother types ofdimmer apparatus Make sure that the power cord is never crimped or damaged by sharp edges Never let the power cordcomeinto...

Страница 4: ...n theretainersattached totheclamp Always ensure that the location that you are goingtomount the unit is secure andis strong enough tosupporttheweight ofthe unit See theWARNINGas shown above Topass SAF...

Страница 5: ...least a 0 5mm diameter Connection to the DMX512 input and output ports of the unit is via 5 pin XLR plugs and sockets which are included with the unit The XLR s plugs and sockets are connected with wi...

Страница 6: ...OHM resistor across pins 2 and 3 in an XLR plug and insert into the DMX out socket on the last unit in the chain PIN 3 PIN 2 PRODUCT FUNCTION SETUP Control panel with wireless function Control panel...

Страница 7: ...and DOWN you can set the address Press button ENTER toconfirm when powered onnext time it will showthe latest number you saved Press button FUNC it will return tothe upper menuone by one STAND ALONE...

Страница 8: ...ATION MENU Level 1 Level 2 Level 3 Level 4 DMX Address Standard 1 495 Extended 1 470 Reset Are You Sure ConfigSettings DMXChannelMode Default is STd Standard18 Extended43 PanTiltSwap Default is OFF OF...

Страница 9: ...on 0 255 Pan 0 127 Stop 128 191 Pan Speeds in CW from slowto fast 192 255 Pan Speeds in CCW from slowto fast TiltLocation 0 255 Tilt 0 127 Stop 128 191 Tilt Speeds in CW from slowto fast 192 255 Tilt...

Страница 10: ...send parameters shouldbe set as a Master and others beas Slaves 3 Mark content applies onlyto the wireless receivingfunction effective use DMX PROTOCOL Standard Extended Functions DMX Descriptions 1...

Страница 11: ...Area5 26 Area 6 Blue 000 255 LinearadjustmentinBluefromlight todark of Area6 27 Area 7 Blue 000 255 LinearadjustmentinBluefromlight todark of Area7 9 28 Area 1 White 000 255 LinearadjustmentinWhitefr...

Страница 12: ...ttons are Locked buttons are unlocked and lock logo disappears after Enter button pressed morethan 3 seconds MAINTENANCE If the Fixture does not function check if the fuses on the power socket of the...

Страница 13: ...TION The fixturecan not start Check ifthe fuse on the power socket is broken or not Check the status ofthe fuse Thelampworksnormalbut thefixturedoesn t respondtothe controller Check ifthe fixture s st...

Страница 14: ...42 FieldAngle 1 10 Maximum 17 60 CONTROL DMX512 5pin interfaces 18channels in standardmode and43 channels in extended mode Master slave mode Stand alone mode Preset mode Selftest mode Single Scenemode...

Страница 15: ...192010184 1 PCS 2 20WLEDASSAMBLY 230060361 1 PCS 3 LENS 1 071100058 7 PCS 4 LENS 2 071100059 7 PCS 5 FUSE 270041037 1 PCS 6 TILT PAN BELT 290151413 2 PCS 7 8025FAN 030060099 1 PCS 8 4010 FAN 030060093...

Страница 16: ...16 18 IRCUIT DIAGRAM...

Страница 17: ...17 18...

Страница 18: ...18 18 PR LIGHTING LTD 1582 XingyeAvenue Nancun Panyu Guangzhou 511442 China TEL 86 20 3995 2888 FAX 86 20 3995 2330 P N 320020266 Version 20141013...

Отзывы: