The following points are important for safety as well as for the smooth 
installation and performance of the unit. 

 
When unpacking and before disposing of the package check there is no transportation damage 
before using the projector. Should there be any damage caused by transportation, consult your 
dealer and do not use the apparatus. Keep the package well for your possible future 
transportation. 
 
The projector is intended for outdoor use and is splash-proof, IP44. Install only in dry and plain 
locations. Avoid excessive moisture. 
  
The projector is not designed or intended to be mounted directly on to inflammable surfaces.

 

 

The projector is only intended for installation, operation and maintenance by qualified personnel. 
 
The projector must be installed in a location with adequate ventilation, at least 50cm from 
adjacent surfaces. Be sure that all the cooling fans run normally and no ventilation slots are 
blocked. 
 
Do not project the beam onto inflammable surfaces. Minimum distance is 5m.   5m   
 
Avoid direct exposure to the light from the lamp. The light is harmful to the eye. 
 
Do not attempt to dismantle and / or modify the projector in any way. 
 
Electrical connection must only be carried out by qualified personnel. 
 
Before installation, ensure that the voltage and frequency of power supply match the power 
requirements of the projector. Only use the lamp with the specified type and rating. 
 
It is essential that each projector is correctly earthed and that electrical installation conforms to all 
relevant standards. 
 
Do not connect this device to any dimmer pack. 
 
Make sure that the power-cord is never crimped or damaged by sharp edges. Never let the 
power-cord come into contact with other cables. Only handle the power-cord by the plug. Never 
pull out the plug by tugging the power-cord. 
 
Keep the lamp clean. Do not touch the lamp glass with bare hand. 
 
The lamp used in this projector is a high power discharge lamp. After being switched off don’

attempt to restart the projector until lamp has cooled, this will require approx 15 minutes. 
Switching the lamp on and off at short intervals will reduce the life of both the lamp and the 
projector. Occasional breaks will prolong the life of both the lamp and the projector. 
 
Never run the projector without a lamp. 
 
There is no user serviceable parts inside the projector do not open the housing and never operate 
the projector with the covers removed. 
 

Always disconnect from the mains, when the device is not in use or before 
cleaning it or before attempting any maintenance work.  

 
If you have any questions, don’

t hesitate to consult your dealer. 

SAFE USAGE OF THE PROJECTOR 

Содержание CENTURY SPOT

Страница 1: ...formation about the safe installation and use of this projector Please read and follow these instructions carefully and keep this manual in a safe place for future reference PR LIGHTING LTD Yingbin Ro...

Страница 2: ...be any damage caused by transportation consult your dealer and do not use the apparatus But any damage caused by improper use will not be assumed by the manufacturer and or dealer THESE ITEMS ARE PAC...

Страница 3: ...ed out by qualified personnel Before installation ensure that the voltage and frequency of power supply match the power requirements of the projector Only use the lamp with the specified type and rati...

Страница 4: ...he beam path Don t touch the bulb by bare hand Close the dichroic colour filter bracket and install projector head cover Make sure that all screws and retaining clips are tightened Note The HMI series...

Страница 5: ...confirm The green LED will flash one time which means that apparatus has saved your setting The setting will be displayed when you turn on next time In stand alone mode the DMX start address could be...

Страница 6: ...th each core having at least a 0 5mm diameter Connection to and from the projector is via an XLR control cable with 3 pin plug and socket which are included with the projector The XLR s are connected...

Страница 7: ...ons are illustrated below Many luminaires can run synchronously by linking them with each other in the master slave mode Set the address of all luminaires to 001 Select one luminaire as the master and...

Страница 8: ...Connect the controller s output to the 1st luminaire s input and connect the 1st luminaire s output to the 2nd luminaire s input The rest may be connected in the same way Eventually connect the last l...

Страница 9: ...hould be cleaned every 15 days The dichroic colour filters should also be regularly cleaned to maintain an optimum light output Do NOT use any type of solvent on dichroic colour filters Cleaning frequ...

Страница 10: ...0 K Manufacturers Rated Lamp life 500 Hours Protocol Standard DMX 512 Running mode Stand alone Master Slave and DMX Controller DMX channels 6 channels Colours 3 basic colours CYM 256 colours continuou...

Страница 11: ...Century Spot manual_Last Revision_en doc 11 14 ELECTRICAL DIAGRAM...

Страница 12: ...4 pcs 030060019 230V 19W FAN 030060042 220V 50 60Hz LAMP 100050024 HMI 2500W SE CAPACITOR 4 pcs 140010018 60 F AC 370V MOTOR 030040029 17HS1013L MOTOR 030040097 17HS1013 10L IC1 230040093 Digital PCB...

Страница 13: ...Century Spot manual_Last Revision_en doc 13 14...

Страница 14: ...tury Spot manual_Last Revision_en doc 14 14 PR LIGHTING LTD No 571 Yingbin Road Dashi Panyu Guangzhou China Post Code 511430 TEL 86 20 8478 1888 FAX 86 20 8478 6023 P N 320040047 Last Revision 02 08 2...

Отзывы: