background image

4 2223V102-UK

HAZARD- 

OUS

VOLTAGE

INSTAL-

LATION

GENERAL

Warning

This device is designed for connection to hazardous electric voltages.
Ignoring this warning can result in severe personal injury or mechanical damage.
To avoid the risk of electric shock and fire, the safety instructions of this manual must be observed and 
the guidelines followed.
The specifications must not be exceeded, and the device must only be applied as described in the 
following.
Prior to the commissioning of the device, this manual must be examined carefully.
Only qualified personnel (technicians) should install this device.
If the equipment is used in a manner not specified by the manufacturer, the protection provided by the 
equipment may be impaired. 

Warning

Until the device is fixed, do not connect hazardous voltages to the device.
The following operations should only be carried out on a disconnected device and under ESD-safe 
conditions: 
 

Dismantlement of the device for setting of DIP switches and jumpers.

 

General mounting, wire connection and disconnection. 

 

Troubleshooting the device. 

 

Repair of the device and replacement of circuit breakers must be done by PR electronics A/S only.

Warning

To keep the safety distances, devices with two built-in relays must not be connected to both hazardous 
and non-hazardous voltages on the same device’s relay contacts. 
SYSTEM 2200 must be mounted in socket type S3B Releco (order no 7023).

Symbol identification

Triangle with an exclamation mark: 

Read the manual before installation and commissioning of the 

device in order to avoid incidents that could lead to personal injury or mechanical damage. Warning / 
demand. Potentially lethal situations.

The CE mark 

proves the compliance of the device with the essential requirements of the directives. 

The UKCA mark 

proves the compliance of the device with the essential requirements of the statutory 

requirements.

The double insulation symbol 

shows that the device is protected by double or reinforced insulation. 

Содержание 2223

Страница 1: ...PERFORMANCE MADE SMARTER Product manual 2223 Dual switchmode power supply TEMPERATURE I S INTERFACES COMMUNICATION INTERFACES MULTIFUNCTIONAL ISOLATION DISPLAY No 2223V102 UK From serial no 191131001...

Страница 2: ...ication interfaces that can access your PR installed base of products All the interfaces are detachable have a built in display for readout of process values and diagnostics and can be configured via...

Страница 3: ...ontents Warning 4 Symbol identification 4 Safety instructions 5 How to dismantle system 2200 6 Application 7 Technical characteristics 7 Mounting 7 Input 7 Output 7 Electrical specifications 8 Order 9...

Страница 4: ...e and under ESD safe conditions Dismantlement of the device for setting of DIP switches and jumpers General mounting wire connection and disconnection Troubleshooting the device Repair of the device a...

Страница 5: ...alternatively PR electronics A S www prelectronics com Mounting and connection of the device should comply with national legislation for mounting of electric materials i e wire cross section protecti...

Страница 6: ...2 After this the back panel can be pulled out together with the PCB but please notice the position of the PCB as there is a number of different positions in the house Do not pull the wires unnecessar...

Страница 7: ...t circuit if the internal temperature exceeds 100 C Mounting The 2223 is for standard 11 pole socket mounting in all positions To achieve maximum cooling of the device mounting in a vertical position...

Страница 8: ...10 max load 250 mV Temperature coefficient 0 05 C Effect of supply voltage change 10 30 mV EMC immuni ty influence 0 5 E lectrical spe cifications INPUT Supply voltage 21 6 26 4 VAC 103 5 126 5 VAC 2...

Страница 9: ...VAC 24 VAC A B D Special 5 24 V 24 VDC 15 VDC 12 VDC 5 VDC 0 1 2 3 4 Special 5 24 V 24 VDC 15 VDC 12 VDC 5 VDC 0 1 2 3 4 9 8 10 11 2 5 C 100 2223 V out 1 V out 2 Output 1 Output 2 gnd Output 1 gnd Out...

Страница 10: ...10 11 11 11 11 5 24 VDC 10 48 VDC 10 48 VDC Serial connection supply Serial connection or 10 48VDC 2 different pos supplies with common ground 2 different neg supplies with common ground 5 24 VDC 5 24...

Страница 11: ...2223V102 UK 11 Document history The following list provides notes concerning revisions of this document Rev ID Date Notes 102 2232 UKCA added...

Страница 12: ...ntation We are headquartered in Denmark and have offices and authorized partners the world over We are a local business with a global reach This means that we are always nearby and know your local mar...

Страница 13: ...ndards for products communicating monitoring and connecting our customers process measurement points to their process control systems Our innovative patented technologies are derived from our extensiv...

Отзывы: