9116QF01
LERBAKKEN 10, 8410 ROENDE DENMARK
Revision date:
2010-02-12
Version Revision
V5 R0
Prepared by:
PB
Page:
2/4
Terminal 51-52, 51-53
Terminal 51-52, 51-53
Ui, Vmax
30 V
Ui, Vmax
30 V
Ii, Imax
120 mA
Ii, Imax
120 mA
Pi
900 mW
Pi
900 mW
Ci
3 nF
Ci
3 nF
Li
1 μH
Li
1 μH
Uo, Voc
28 V
IIC or A,B
80 nF
4 mH 54 μH/Ω
Uo, Voc
21.4 V IIC or A,B
0.16 μF
4 mH 54 μH/Ω
Io, Isc
93 mA IIB or C,E,F
640 nF
16 mH 218 μH/Ω
Io, Isc
93 mA IIB or C,E,F
1.13 μF
16 mH 218 μH/Ω
Po
650 mW IIA or D,G
2.1 μF
32 mH 436 μH/Ω
Po
650 mW IIA or D,G
4.15 μF
32 mH 436 μH/Ω
Uo, Voc
28 V
IIC or A,B
80 nF 1000 mH 4 mH/Ω
Uo, Voc
21.4 V IIC or A,B
0.16 μF 1000 mH 4 mH/Ω
Io, Isc
1.1 mA IIB or C,E,F
640 nF 1000 mH 17 mH/Ω
Io, Isc
1.1 mA IIB or C,E,F
1.13 μF 1000 mH 17 mH/Ω
Po
8 mW
IIA or D,G
2.1 μF 1000 mH 35 mH/Ω
Po
8 mW
IIA or D,G
4.15 μF 1000 mH 35 mH/Ω
Uo, Voc
8.3 V
IIC or A,B
7 μF 1000 mH 100 mH/Ω
Uo, Voc
8.3 V
IIC or A,B
7 μF 1000 mH 100 mH/Ω
Io, Isc
0.2 mA IIB or C,E,F
73 μF 1000 mH 400 mH/Ω
Io, Isc
0.2 mA IIB or C,E,F
73 μF 1000 mH 400 mH/Ω
Po
0.4 mW IIA or D,G
1000 μF 1000 mH 800 mH/Ω
Po
0.4 mW IIA or D,G
1000 μF 1000 mH 800 mH/Ω
Uo, Voc
8.3 V
IIC or A,B
7 μF
207 mH
1 mH/Ω
Uo, Voc
8.3 V
IIC or A,B
7 μF
207 mH
1 mH/Ω
Io, Isc
13.1 mA IIB or C,E,F
73 μF
828 mH
5 mH/Ω
Io, Isc
13.1 mA IIB or C,E,F
73 μF
828 mH
5 mH/Ω
Po
27.3 mW IIA or D,G
1000 μF 1000 mH 10 mH/Ω
Po
27.3 mW IIA or D,G
1000 μF 1000 mH 10 mH/Ω
Co
Lo
Lo/Ro
Module 9116B1
Terminal 41,42,43,44
Group
Co
Group
Co
Lo
Lo/Ro
Module 9116B1
Terminal 51-52
Group
Co
Lo
Lo/Ro
Module 9116B2
Terminal 51-52
Group
Co
Lo
Lo/Ro
Module 9116B1
Terminal 51-53
Group
Co
Lo
Lo/Ro
Module 9116B2
Terminal 51-53
Group
Module 9116B1
Module 9116B2
Module 9116B1
Terminal 51-54, 52-54
Group
Co
Lo
Lo/Ro
Module 9116B2
Terminal 51-54, 52-54
Group
Lo
Lo/Ro
Module 9116B2
Terminal 41,42,43,44
Co
Lo
Lo/Ro
Installation notes:
1) The installation shall be in accordance with the National Electrical Code NFPA 70, Article 500 or
505.
2) For installation in Zone 2 or Division 2, the module must be installed in a suitable outer enclosure
having an IP protection of at least IP54.
3) The module is galvanically isolated and does not require grounding.
4) Install in pollution degree 2 or better.
5) Use 60 / 75 ºC copper conductors with wire size AWG: (26-14).
6)
Warning
: Substitution of components may impair intrinsic safety.
7)
Warning
: To prevent ignition of the explosive atmospheres, disconnect power before servicing and
do not separate connectors when energized and an explosive gas mixture is present.
8) In type of protection “intrinsic safety iD” the parameters for intrinsic safety for gas group IIB are
applicable.
9) Warning
: Do not mount or remove modules from the Power Rail when an explosive gas mixture is
present.
PENDING