General Precautions
The Firelight fixture is intended for indoor special effect applications in theme parks, themed attractions,
themed restaurants or scenic displays, and for any other specialized lighting application where the
appearance of fire or flames is desired, without any of the hazards or difficulties associated with real fire.
The user should be aware that the projector output produces an extremely realistic flame effect, which can
easily be mistaken for an actual fire under the right circumstances. Accordingly, the user is advised to be
careful when installing the unit, and to inform others in areas close to the intended effect or display in order
to avoid “false alarm” calls to local fire departments.
CAUTION
The fixture is intended only for indoor use in dry locations. The unit is not intended for outdoor use,
or for indoor use in close proximity to an actual body of water. The fixture is not rated for, nor
protected against water splash, droplets, or mist.
Electrical Precautions
The Firelight projector is provided with a Class II AC power supply with a total cord length of 4 feet
minimum. The AC power supply has a standard two or three pin pin AC power connector which may be
plugged into any suitable AC outlet. The output connector of the power supply has a coaxial DC power
connector which mates with the input socket at the rear of the Firelight fixture. To connect the Firelight to
the power supply, install the coaxial plug into the socket at the rear of the unit. Once the DC connector is
attached, the power supply may be connected to the AC power source.
WARNING
The Firelight FL-L1 models usually include a “Universal Voltage” AC power supply which operates
on 100 to 240 volt AC line voltage at either 50 or 60 Hertz. Application of DC voltage or AC voltages
outside of this range to the power supply may cause serious damage to power supply and the fixture,
and may cause increased risk of electrical shock or fire, potentially resulting in serious injury or
death. Do not attempt to operate the unit with incorrect or unknown supply voltages.
Do not operate any universal voltage power supply from a dimmed AC lighting circuit.
DC Power Connections
For applications where DC power is available, the AC power supply may be omitted, and the fixture
operated directly by DC power. The recommended DC power supply must have a voltage of 9 volts at a
current of 2 amperes minimum. The DC power input socket on the fixture is a standard 2.1 mm female
coaxial DC socket, where the 2.1 mm center pin is the positive connection, and the outer sleeve is negative.
The output connector of the DC power supply should be equipped with a male coaxial DC power plug,
wired with correct polarity to mate with the input socket at the rear of the Firelight fixture.
WARNING
The FL-L1 Firelight fixtures are designed to operate on 9 volt DC power. Application of AC voltage,
incorrectly polarized DC voltage, or DC voltages outside of the normal range to the fixture may cause
serious damage to the power supply and the fixture, and may cause increased risk of electrical shock
or fire, potentially resulting in serious injury or death. Do not attempt to operate the unit with
incorrect or unknown DC supply voltages.