F10R REFLECTIVE PHOTOCELL DETECTOR
INSTRUCTION MANUAL
COMFORT AND SECURITY
INSTALLATION
X
F10R Reflective
photocell detector
PHOTOCELL DETECTOR FEATURES:
P04985 - Rev. 2
PRECAUTIONS
SPECIFICATIONS
- Max range: 08 meters (~26.25 feet)
- Operating voltage: 12Vdc - 24Vdc;
- Current drain: 80mA;
- NO and NC outputs;
- Immediate triggering;
- Pulsed output for PPA Control boards.
Round Reflector
Connection terminal
( + ) ( - ):
The device must be powered
by a 12Vdc - 24Vdc auxiliary power
supply;
P:
Pulsed output for PPA Control
boards;
NA, C and NF:
Relay dry contact
outputs. Used for circuit keying
when the photocell is used in
normal mode, either open or closed.
Step 1: Attach the photocell detector the same side the control
board is installed, since it will both receive commands from it and
power it up. The receiver is attached the opposite side, with the
transmitter and receiver facing each other. When attaching the
round reflector, mind the (Installation) Position Indicator, it must
face up.
( ). The photocell detector must be attached so
that the opening for the wiring faces down, in order to
avoid accidental water entering.
A installation diagram can be seen on the previous page.
- Make sure the
wiring is facing down;
- Install the photocell
away from obstacles
which could block the
beam.
LED Indicator
Transmitter
Receiver
Wiring
Position indicator
(for installation)
The height indicated by an “X” refers to the height of the
possible objects which will be detected by the device, such as
vehicles, people and pets. For example, for a 50cm (~1.65f) high
vehicle, the photocell detector must be installed over this
height, otherwise it will not detect the vehicle. One must
observe the minimum height (30 cm - ~0.99f), in order to both
ensure a proper operation and avoid false alarms.
Note:
There is no maximum height for installing the photocell
detector.