COMFORT whit SECURITY
COMFORT whit SECURITY
Page
08
RECORDING ELECTRONIC LOCK TRANSMITTER
It locks and unlocks all access buttons memorized in control unit and external
command. Only the last 4 electronic lock transmitters will be memorized.
Steps to memorize the transmitters:
Step 1:
Keep jumper HRF and jumper HC closed.
Bring transmitter close to receptor, press and keep
one button pressed (left or right).
Step 2:
Press “Aprender” button and keep it pressed.
The Led (SN) will start blinking every second (clock
mode), signaling that it received the transmitter code.
Step 3:
Release transmitter button.
Step 4:
Release “Aprender” button, after 6 to 10 seconds.
The Control unit will signal through the led (SN) with one (01)
blink that it memorized electronic lock transmitter.
To continue memorizing remaining buttons, repeat the
procedure.
Step 5:
Jumper HC open.
TURNING ON ELECTRONIC LOCK
Step 1:
Keep jumper HRF closed.
Step 2:
With gate closed, press and release the right
button of the electronic lock. The control unit will signal
through the led (SN), with 01 blink that it recognized
electronic lock button. Next, the led (SN) will start blinking
once every 2 seconds in the reverse mode (i.e., led stays
on and turns off rapidly).
Step 3:
From this moment, all access buttons and external
command will be unlocked.
IMPORTANT
:
Even when turning control unit on and off through electric
source, it will go back to the stage of lock on.
In case of electronic lock transmitter is lost and the control
unit has lock on, it will be necessary to call an Authorized Technical.
Service.
TURNING OFF ALL BUTTONS
Steps to turn off all buttons:
Step 1:
Keep jumper HRF closed. Press “Aprender” button and
keep it pressed.
Step 2:
Bring one of the recorded transmitters to the
receptor, press and release button (left or right). The led
(SN) will start blinking every second (clock mode),
signaling that it received the transmitter code.
Step 3:
After 25 seconds, with the “Aprender” button
pressed, the led (SN) will turn off and it will signal as
described below:
* 4 blinks, only once (buttons are off)
* 5 blinks, only once (button used for “turn off” function is invalid.
Therefore, function is canceled).
IMPORTANT:
The central unit will only permit to clear the buttons in its
memory if motor and lock function are turned off.
TURNING OFF ELECTRONIC LOCK
Step 1:
Keep jumper HRF closed.
Step 2:
Press and release the left button of the
electronic lock. The control unit will signal through the
led (SN) with one blink that it recognized the electronic
lock button. Next, the led (SN) will start blinking once
every 2 seconds in normal mode (i.e., led stays off
and turns on rapidly).
Step 3:
From this moment, all access buttons and
external command will be unlocked.
IMPORTANT
:
The control unit will only allow the memorization of one
electronic lock transmitter if motor and lock function are turned off.
Only 4 transmitters will be memorized. Consequently, the
most recent lock transmitter memorization will cancel the first.
With the electronic lock turned on, the control unit will cancel
all attempts of trimpots memorization.
Page
09