Note: APS = Air Pressure Switch
Yes
Yes
Yes
Burners light?
Check ignition electrode position. Is gas pipe work purged of air? Check gas pressures. Replace gas valve
4 more ignition attempts then lock out.
Exhaust fan continues to run
APS has lost C. to N.O. continuity, slightly reduce APS set point.
Check for 230V between terminals 12 & N of the terminal strip
Absent
Replace motor, capacitor or fan/motor assembly
Check connections, overloads etc as applicable
Absent
Finish
Burners remain alight?
No
No
No
After warm up
Main fan runs?
Yes
Depending on fan /motor type - Check for 230V at
the main fan motor
Check connections. Fan/limit
thermostat faulty - check/replace
Present
Present
Engineers switch inside heater set to manual (set switch to Auto)
Yes
Burner does not stop
when thermostat stops
calling for heat?