POWR RACK11 IM v1
1
POWR RACK11
Rack Mounted Power Conditioner
Instruction Manual
IMPORTANT SAFETY INSTRUCTIONS
1.
Read these instructions. All the safety and operating instructions should be read before the product is operated.
2.
Keep these instructions. The safety and operating instructions should be retained for future reference.
3.
Heed all warnings. All warnings on the product and in the operating instructions should be adhered to.
4.
Follow all instructions. All operating and use instructions should be followed.
5.
Do not use this apparatus near water. Do not use the product near water and moisture, for example: near a bathtub, washbowl,
kitchen sink, or laundry tub; in a wet basement; or near a swimming pool.
6.
Clean only with a dry cloth. Unplug this product from the wall outlet before cleaning. Do not use liquid cleaners or aerosol cleaners.
Use a dry cloth for cleaning.
7.
Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that product
heat.
8.
Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the
other. A grounding-type plug has two blades and a third grounding prong. The wide blade or the third prong is provided for your
safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
9.
Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point where they
exit from the apparatus.
10.
Only use attachments/accessories specified by the manufacturer.
11.
Unplug this apparatus during lightning storms or when unused for long periods of time.
12.
Refer all servicing to qualified service personnel. Servicing is required when the
apparatus has been damaged in any way, such as
power-supply cord or plug is
damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been
exposed to rain or moisture, does not operate normally, or has been dropped.
INSTALLATION
Attach the POWR RACK11 to any 19-inch rack using rack rail screws (not included).
SPECIFICATIONS
•
19-inch rack mount surge protector
•
Peak impulse current 120,000A
•
Digital amperage/voltage meter
•
Transient response time <1 nanosecond
•
Pull out dimmable LED lights
•
Energy dissipation 3,000 Joules
•
11 (10 rear, 1 front) NEMA-15R receptacles
•
EMI/RFI noise filtration 40 dB
•
On/off switch with built-in circuit breaker
•
Noise filtration level 100kHz – 1MHz
•
LED Indicators - Power, Protected, Grounded
•
9-foot heavy-duty power cord
•
Current capacity 12A
•
Dimensions 19.0” x 4.5” x 1.75”
•
Maximum output power 1,500W
•
Weight 5.25 pounds
•
Line voltage 125V AC 60Hz
•
UL, cUL listed (UL60950-1, UL1449)