10
PROBLEM
CAUSE
SOLUTION
Poor pick up.
Inlet basket filter is clogged.
Loose drain hose connection.
Loose recovery tank lid.
Damaged hose.
Suction relief is open on
wand.
Clean filter.
Tighten drain hose.
Position the lid correctly.
Replace hose.
Adjust or close suction relief
on wand.
Vacuum motor does not
operate.
Unplugged cord.
Faulty switch or loose wiring.
Tripped building circuit
breaker.
Defective vacuum motor.
Recovery tank is full.
Check connection to pigtail
and wall.
Contact Service Center.
Reset breaker.
Contact Service Center.
Empty the recovery tank.
Discharge pump does not
operate.
Unplugged cord.
Faulty switch or loose wiring.
Tripped building circuit
breaker.
Defective pump.
Recovery tank is not full
enough.
Check connection to pigtail
and wall.
Contact Service Center.
Reset breaker.
Contact Service Center.
Discharge pump will turn on
when there’s enough water in
the recovery tank.
Amount of discharge water
dwindles
Worn impeller.
Contact Service Center.
Pressure pump does not
operate or has low pressure.
Unplugged cord.
Faulty switch or loose wiring.
Tripped building circuit
breaker.
Defective pump.
Tripped pump circuit breaker.
Check connection to pigtail
and wall.
Contact Service Center.
Reset breaker.
Contact Service Center.
Reset breaker on pump.
TROUBLESHOOTING