Powr-Flite CAS16 Скачать руководство пользователя страница 3

The operating controls are located on the handle.

Brush motor switch

Used to switch motor ON and OFF. Lights when in the ON position.

Neon indicator

Lights when the machine is connected to the power supply

Vacuum motor switch

Used to switch motor ON and OFF. Provides suction at the squeegee.
Lights when in the ON position.

Solution feed triggers

Supplies cleaning solution to the brush head when squeezed.

Handle adjustment lever

Used to adjust handle to comfortable working height.

Thermal reset button

Thermal protects brush motor from overheating. Press button once to
reset cut-out and restart motor.

STARTING THE MACHINE

1. Fully unwind the supply cord and plug in to a convenient socket outlet.
2. With the solution tank filled and the handle set at a comfortable height,

the machine is ready for use.

3. Switch ON the brush motor, followed by the vacuum motor.
4. Release cleaning solution at regular intervals by squeezing the 

handle triggers.

WARNING

– Always ensure adequate solution is on the floor. Scrubbing

without solution could damage the floor surface and/or the machine
brush. Keep the machine moving while the brush is rotating. 

IMPORTANT

– Should the brush stop rotating due to operation of the

thermal reset button on the brush motor, switch the machine OFF and
allow to cool for a few minutes. Press the thermal reset button on left
hand side and restart the machine.

WARNING

– If foam or liquid is emitted, switch off immediately and

empty recovery tank. Liquid emitted could be hazardous as a result of its
temperature, or chemical content.

5. To stop the machine, release solution feed triggers, switch OFF brush 

motor and then vacuum motor.

6. Normal movement of the machine is in a forward and backward 

direction.

7. Proceed to operate the machine in the normal manner, releasing 

cleaning solution as required.

8. For heavy soil, scrub floor with cleaning solution but with vacuum 

motor OFF. Scrub floor again the pick up the solution.

9. When scrubbing is complete, unplug the machine from the power 

supply, empty the solution tank and recovery tanks and clean and 
dry the machine.

IMPORTANT

– Dispose of unused cleaning solution in accordance with

the manufacturer’s directions. 

WARNING 

– Before undertaking maintenance operations or adjust-

ments, switch machine OFF and unplug from the electricity supply.
The machine requires minimum maintenance apart from the following
checks by a trained operator.

Power cord – regularly inspect sheath, plug and cord anchorage for
damage or loose connection. Only replace the power cord with the type
specified in these instructions.

Solution tank – check water flow, if restricted inspect tubing for blockage.
Check that filter is clean and undamaged. A damaged filter must be
replaced.

Recovery tank – check condition and clean tank.
Squeegee blades – check condition and replace worn or damaged
blades.

Solution spray bar – remove the brush to access the spray bar. Check
that the solution feed holes are not blocked or restricted and clean as
necessary.

MAINTENANCE

OPERATION

CONTROLS

Brush motor switch

Neon indicator

Vacuum motor switch

Solution feed triggers

Handle adjustment lever

Thermal reset button

CAS16 manual  4/18/05  9:27 AM  Page 3

Содержание CAS16

Страница 1: ...RCIAL AND HOUSEHOLD COMPACT AUTOMATIC SCRUBBER The CAS16 is a compact electric automatic scrubber designed for small to medium sized areas Equipment must be operated serviced and maintained in accorda...

Страница 2: ...o the work area lock the handle and tilt it back wards to raise the front off the floor and wheel into position Before connecting the machine to the power supply check that the sup ply voltage corresp...

Страница 3: ...be hazardous as a result of its temperature or chemical content 5 To stop the machine release solution feed triggers switch OFF brush motor and then vacuum motor 6 Normal movement of the machine is in...

Страница 4: ...twards 4 Return machine to the floor replace tanks and reconnect hoses 1 When cleaning is finished unplug the machine from the power supply and lift off and empty the recovery and solution tanks over...

Страница 5: ...lution hose not correctly fitted to tank con nector Hose blocked Waterways in spray bar blocked Solution tank empty Blocked filter in solution tank Damaged pump Hose from squeegee blocked or split Squ...

Страница 6: ...rigger 27 CAS33 interlock bottom 28 CAS34 cord retainer ref item description 29 CAS35 handle gear 30 CAS36 gear dog 33 CAS37 solution trigger plate 34 CAS38 gear rod 37 CAS39 cord inlet box 39 CAS40 s...

Страница 7: ...S82 caster wheel CAS83 wheel bearing CAS84 front squeege blade CAS85 squeegee roller assembly CAS86 aluminium pop rivet CAS92 rear squeegee blade CAS87 idler pulley CAS83 bearing for pulley 626 2RS SN...

Страница 8: ...rdance with written manuals or other instructions for a period of 1 year from date of pur chase on workmanship motor and parts In case you as our customer meet any trouble with your machine contact a...