The Charging process

 

 

The charging stages are as follows: 

 

 

 

 

 

Soft start:       

Charges the battery using half the maximum current until the battery   
voltage is over 23V. 

(LED Colour - ORANGE) 

(Soft Start occurs if the initial voltage is less than 23V) 

 
 
 

 

Bulk Charge: 

Charges using a constant maximum current (4A) until the   
battery rises to the absorption level. 

(LED Colour - ORANGE

)             

 

 

 
 

Absorption:    

This stage charges the battery using a constant voltage of 29.0V   

   

 

 

until the Battery Capacity is over approximately 85%.   

 

  

 

 

 

(LED Colour - ORANGE

)           

 

 
 

 

 

 
 

 

Fully Charged:  Battery is fully charged. It will be maintained at a safe constant   

voltage. Float Voltage: 27.4V   

 

   

   (LED 

Colour 

GREEN

)             

                                                 
 

3. Disconnecting the Battery charger from Battery. 

   

(a)  Switch the Battery Charger OFF then Switch the Mains Power OFF and remove the AC 

Power Socket from the outlet. 

 
(b)  Disconnect the Battery Charger fly lead from the battery. 

 
 
 

Содержание PX-2404M

Страница 1: ...opped or damaged Never attempt to charge a damaged battery frozen battery or non rechargeable battery Do not use the charger in a closed area or poorly ventilated area Never smoke use an open flame or...

Страница 2: ...ions before using this charger OPERATING INSTRUCTIONS The PowEx Battery Charger is easy to operate and requires no technical experience 1 Connecting the Battery charger to your Battery a Simply plug t...

Страница 3: ...rises to the absorption level LED Colour ORANGE Absorption This stage charges the battery using a constant voltage of 29 0V until the Battery Capacity is over approximately 85 LED Colour ORANGE Fully...

Страница 4: ...FF Battery Disconnected OFF OFF OFF Charging OFF ON OFF Fully Charged Float Charging OFF OFF ON Output lead short reverse polarity Flash 1 OFF OFF Soft Start Charge Time Out Flash 2 OFF OFF Bulk Charg...

Страница 5: ...he XLR connectors Check that the XLR plugs have been securely connected Check that the XLR plugs have not been forced together incorrectly No Charging Current Fault LED is ON Battery is severely sulph...

Страница 6: ...charge for 2 5 hours until the charging current drops by less than 0 5A 2 4 3 Absorption maximum charging time Tcv limited Force to Float mode when Time out 8 0 5 Hours 2 5 1 Float charging output vo...

Страница 7: ...ip see Exclusions the Customer will be asked to ship to the nearest service point The product must be packaged appropriately for safe shipment To prove that the product is under warranty the customer...

Страница 8: ...PX 2404M User s Manual Rev 1 6 8 PX2404M Owners Manual Website www dcsolutionsaustralia com au...

Отзывы: