PX-2404M User’s Manual - Rev 1.6
3
The Charging process
The charging stages are as follows:
●
Soft start:
Charges the battery using half the maximum current until the battery
voltage is over 23V.
(LED Colour - ORANGE)
(Soft Start occurs if the initial voltage is less than 23V)
●
Bulk Charge:
Charges using a constant maximum current (4A) until the
battery rises to the absorption level.
(LED Colour - ORANGE
)
●
Absorption:
This stage charges the battery using a constant voltage of 29.0V
until the Battery Capacity is over approximately 85%.
(LED Colour - ORANGE
)
●
Fully Charged: Battery is fully charged. It will be maintained at a safe constant
voltage. Float Voltage: 27.4V
(LED
Colour
-
GREEN
)
3. Disconnecting the Battery charger from Battery.
(a) Switch the Battery Charger OFF then Switch the Mains Power OFF and remove the AC
Power Socket from the outlet.
(b) Disconnect the Battery Charger fly lead from the battery.