Specifications
• Amperage Rating:
35 Amps max @ 12V continuous
duty
• Low Standby Current Draw:
5mA in standby mode,
100 mA normal operation mode
• Reconnect Voltage:
12.7 VDC
• Compact Size:
3½”L x 2”W x 1½”H
• Weight:
0.5 lbs. (229 grams)
• Construction:
Potted water proof design. Can be
mounted inside an engine compartment.
• LED Status Indicators:
o
Solid Green LED light = power passing through
normally
o
Flashing Green LED light = Selected LVD level has
been reached-waiting for disconnect delay to
turn OFF.
o
Slow Flashing Red LED light = LVD level reached
and output to load is OFF
o
Solid Red LED light = Overvoltage Condition
• Connections:
+/- Power IN from Battery. +Power
OUT to electronics, negative is optional on OUT (no
ignition wire required). Emergency Override Switch.
Troubleshooting
Unit will not turn ON:
•
Check for reverse polarity on Input and Output
connections
•
Check that Battery power is connected to the Input
connection
LED Lights Not Working:
•
Check (-) Negative Input connection for good ground
to battery
•
Check Input (+) positive connection
Red LED Light Solid ON:
•
Input power is over 16.5V, reduce input voltage to
15V or less, unit will auto-reset
Warranty:
Powerwerx support policy is simple; we want you to be
happy! If you have a problem, please feel free to contact
us and we will do our best to get you up and running as
soon as possible.
The Powerwerx LVD-35 has a one-year limited warranty.
We will repair or replace your LVD-35 if you encounter
any problems within one year of purchase. We reserve
the right to charge a reasonable fee for repairing units
with user-inflicted damage. It is your responsibility to
ship the defective unit back to Powerwerx. We will pay
for shipping the replacement to you within the warrantee
period.
LVD-35 ▪ Rev 4/2015
Also Look at our Other Models:
ITS-12 – DC Timer/LVD – Battery Guard
•
Heavy Duty design rated at 35A continuous
duty
•
Selectable low voltage disconnect (11.4 or 11.0
VDC)
•
User selectable timer positions (2, 15, 30
minutes, 1, 2, 3, 4, 5, 8, 12 hours)
•
Auto Reconnects when Voltage returns to safe
level
APS-12 – DC Automatic Power Switch/Timer
•
No ignition connection required: Automatic
On/Off Operation
•
Ideal for all 2-way radios, computers and DC
electronics – 25A current rating
•
User selectable timer positions (2, 15, 30
minutes, 1, 2, 3, 4, 5, 8, 12 hours)
More information at: www.powerwerx.com
LVD-35 User Manual
23695 Via Del Rio, Yorba Linda, CA 92887 ▪ 714-674-0073 Phone ▪ 714-674-4949 Fax
ÑLVD-353Ó