MCPA Installation Instructions
G3L-1929-160-001 MCPA
3-2
044-05305 Rev A
The modular MCPA can be installed in a variety of systems. All system connections to the MCPA are
made through the MCPA rear connector, no additional wiring is required. Perform the steps in Table
3-2 to install the MCPA. Refer to Figure 3-1 for quarter-turn fastener position and switch location.
Table 3-2 MCPA Installation
Step
Action
1
Set MCPA OFF/ON/RESET switch to the OFF (down) position.
2
Ensure quarter-turn fasteners are in unlocked position.
3
Lift and insert MCPA into the subrack. Turn the quarter-turn fasteners to locked
position to secure MCPA into subrack.
Figure 3-1 MCPA Quarter-Turn Fasteners and Connectors
RF Switch:
RJ-11
Connector
(Factory use only)
Quarter-turn
fastener
RESET
ON
OFF
Quarter-turn
fastener
Interface
Connector
Unlocked
Locked