Troubleshooting
Nexus FT
4-2
044-05251 Rev B
Ceasing
PSU2 in the cover works properly again. Ceasing is sent if the
PSU2 works at start-up, and there is a corresponding critical
PSU2 alarm logged in the Events Log. The WRH will restart when
the power is back and this alarm will be sent
Power
FON
Error
The FON 10 Volt charger voltage is below limit. Suggested
remedy: Replace the FON
Ceasing
The cause of the alarm has ceased
2
WRH restart
CU
None
Power on start, or user ordered reboot. Logged to indicate a
normal power up, or a restart ordered by the operator
Warning
Software error restart, 1st – 7th time. Restart 1st to 7th time during
a 14 day period. The counter is reset every 14th day, counted
from power up
Error
Software error restart 8th – 10th time. Restart 8th to 10th time
during the 14 day period. At the 11th time, the SW bank will be
blocked and not used anymore until a user ordered reset is
performed, or power is switched off/on
3
Mains
breakdown
External
Critical
The mains power is gone. Used with an external relay indicating
mains breakdown. The external relay should be connected to
External Alarm 1 and the WRH configured to indicate this alarm. If
no relay is used, a mains breakdown will be reported as a PSU
fault
Ceasing
The mains power is back. Sent if there is a corresponding critical
mains breakdown alarm logged in the Events Log. The WRH will
restart when the power is back
4
Alarm reset
CU
None
Alarm reset by the user. All alarms are reset. The cause of the
alarm will be re-evaluated and reported, if still active
5
Local bus
error
WBA #,
MCPA#
Error
Error when communicating on the bus. The CU has no contact
with the WBA, or MCPA PCBA, which is taken out of service
6
Main bkd w
backup
External
Error
Used to indicate that the mains is no longer available. WRH is
powered by external battery backup unit. Suggested remedy:
Check the mains power
Ceasing
The cause of the alarm has ceased
7
Err in AD-
converter
Warning
The analog-to-digital converter on the CU PCBA does not give
reliable values
8
New unit
detected
None
Compared to the last power on, the CU has recognized at least
one additional hardware unit
9
Inst. unit lost
Error
Compared to the last power on, the CU lacks at least one
hardware unit
10
EEPROM
error
CU
Error
EEP read or write fail. Data cannot be written or read from the
EEPROM on the CU PCBA. User parameters are stored in the
EEPROM
11
Log memory
fault
Error
Log memory fault. Indicates that the log memory on the CU PCBA
is faulty. The WRH will not work. Not available in all CU software
versions
Table 4-2 Alarm Troubleshooting (Continued)
ID
Alarm Text
Alarm Unit
Alarm
Description