background image

  

  

 

 

 

 

 

 

 

© 2005 Powerwave Technologies Incorporated. All rights reserved. 

Powerwave Technologies, and the Powerwave logo are registered trademarks. 

This Powerwave product is intended only for installation in a RESTRICTED 
ACCESS LOCATION and is designed to operate within the Normal Operating 
(typical operating) ranges or conditions specified in this document. Operation of 
this equipment beyond the specified ranges in this document may cause: 

1. Spurious emissions that violate regulatory requirements. 

2. The equipment to be automatically removed from service when maximum 
thresholds are exceeded. 

3. The equipment to not perform in accordance with its specifications.  

It is the Operator's responsibility to ensure this equipment is properly installed and 
operated within Powerwave operating specifications to obtain proper performance from 
the equipment and to comply with regulatory requirements.

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание LinkNet LNKA100

Страница 1: ...DCM000000054 Rev Q October 2005 LinkNet LNKA100 LNKF400 LNKA800 RF BROADBAND AMPLIFIER MODULES User Installation Operation and Maintenance Manual...

Страница 2: ...ument Operation of this equipment beyond the specified ranges in this document may cause 1 Spurious emissions that violate regulatory requirements 2 The equipment to be automatically removed from serv...

Страница 3: ...mbol means danger You are in a situation that could cause bodily injury Before you work on any equipment be aware of the hazards involved with electrical and RF circuitry and be familiar with standard...

Страница 4: ...ion Record ii DCM000000054 Rev Q Revision Record Revision Letter Date of Change Reason for Change Q October 2005 Added 700 MHz models misc corrections P July 2005 Converted Kaval Rev 14 to Powerwave F...

Страница 5: ...ET UP 2 1 2 2 CONFIGURATION 2 1 2 3 DERATING CHART 2 2 2 4 POWER ON SELF TEST POST 2 2 2 5 FAULT INDICATIONS 2 3 2 6 NORMAL OPERATION 2 3 Chapter 3 Antenna Installation 3 Introduction 3 1 3 1 ANTENNA...

Страница 6: ...00000054 Rev Q TABLE OF FIGURES Figure 1 Block Diagram LNKA RF Module 1 2 Figure 2 LNKA Faceplate 2 3 TABLE OF TABLES Table 1 LNKA Module Family 1 1 Table 2 LNKA Module Specifications 1 3 Table 3 LNKA...

Страница 7: ...kNet Amplifier Module systems is that of input to output antenna isolation This must be carefully engineered for each installation LinkNet Amplifier Modules are designed for indoor use only and are in...

Страница 8: ...without TCXO RF Input RF Output Micro Controller with lines to all Boards SMA RF Connector SMA RF Connector Power Control to Backplane Filter Linear Power Amplifier Figure 1 Block Diagram LNKA RF Mod...

Страница 9: ...57 dBm Max Group Delay 200 nS 100 nS Variation across Passband Input Return Loss 14 dB RF Connectors SMA 50 Connectors Module Power Supply Requirements 40 Watts Maximum Connections Edge Connector 2 SM...

Страница 10: ...1 4 DCM000000054 Rev Q This page intentionally left blank...

Страница 11: ...control cable to connect between the appropriate module s DB15 connector on the back of the card cage and the standard DB9 RS232 connector on the PC On the PC a terminal emulation program such as Hype...

Страница 12: ...gies for more information 2 4 Power On Self Test POST Each module automatically performs a self diagnostics when inserted into the system card cage These tests determine that the unit is correctly ins...

Страница 13: ...al Emulator using the LIST command 2 6 Normal Operation The LNKA Module has six LED s on the faceplate OPERATING LED will flash GREEN when RF Data is present and unit is operating normally STANDBY Und...

Страница 14: ...2 4 DCM000000054 Rev Q This page intentionally left blank...

Страница 15: ...ess it and that under normal operating conditions no other person can touch the antenna or approach within 10 meters of the antenna For the Cellular Uplink Band 824 849 MHz the Roof Top Antenna or Ant...

Страница 16: ...found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equi...

Страница 17: ...466 1000 to obtain this number or FAX your request to 1 714 466 5816 or mailto RMA PWAV COM Failure to obtain this RMA number may result in delays in receiving repair service 4 1 2 Repackaging For Shi...

Отзывы: