5.5 Audio alarm reminder instruction 

 

Equipment 

running normal 

Buzzing 

prohibit 

Buzzer is no tweet under default 

status. 

Buzzer 

starts 

Buzzer tweet 4 times every 15s, 

indicate the equipment operated 

under battery inverter status. 

Battery high 

voltage alarm 

Buzzer  tweets  4  times  per  second,  alarms  high 

voltage 

Battery low 

voltage alarm 

Buzzer  tweets  2  times  per  second,  alarms  low 

voltage 

Over 

temperature 

alarm 

 

Buzzer alarm 2 seconds pause 1 second 

 

5.6 Electric Generator Connection Announcements: 

When connecting an electric generator: 

5.6.1 Make sure the generator output voltage is matched to the MPS unit 

AC input range. Turn off all the AC switches, wire the generator output to 

MPS unit AC input terminals according to the instructions. Start the 

generator and       have it running stable. Then make sure the unit output has 

no-loads connected. Then start the unit. 

5.6.2 After the unit is started, connect the loads one by one. 

5.6.3 We suggested generator capacity be 2~3 times that of this unit. 

 
 
 
 
 
 
 
 
 
 

 
 

-20- 

6 Maintenance 

6.1 This series of product requires little maintenance, battery only needs 

to maintain its charge for full life expectancy.  

6.2 If you do not use the equipment for a long period of time, it is 

recommended it be charged every 4-6 months. Under normal 

circumstances, 

the battery’s life will be 3-5 years, if found in poor condition, 

you must replace the battery early. Replacement of the battery must be 

carried out  by qualified personnel. Battery should not be individually 

replaced; the overall replacement should follow the battery supplier's 

instructions. 

6.3  In moderate climates every 4 to 6 months the battery must be discharged 

to shut down and recharged to full capacity. In high temperature regions the     

battery discharge and charge should be done every 2 months. 

6.4  Before replacing the battery, turn off the device and disconnect it from 

the main and close the battery switch. Remove all metal objects such as rings 

and  watches.  Use  insulated  handles  and  screwdrivers,  do  not  put  tools  or 

other metal objects on the battery pack. 

6.5  When  connecting  the  battery  cable,  it  is  normal  for  small  sparks  to 

appear which will not cause any harm to equipment or the personal safety 

and the operator. Do not cross connect the battery terminals. 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
-21- 

Содержание PT-3000

Страница 1: ...User Manual PT 3000 Powertronics Inc 370 Mountain St Willimantic CT 06226 844 241 1046 www powertronics us ...

Страница 2: ...w voltage protection overload protection short circuit protection over temperature protection Intelligent MPPT solar controller with over charge over discharge protection and current limiting charging protections 2 Installation Storage Instructions 2 1 Out of Package Inspection 2 1 1 Open and inspect the equipment for damage please ensure the Quick Start and user manual are present 2 1 2 If the eq...

Страница 3: ...Guide 5VDC Output USB sockets AC Outlets 12VDC Output Guide AC Input Socket AC charger Cooling Fan Solar Input Breaker Battery Input Breaker AC Input Breaker AC Output Breaker External Battery Input Terminals Solar Input Terminals Solar Charger AC Input Terminals AC Output Terminals ...

Страница 4: ... 2 3 ...

Страница 5: ... Scroll down set key Under the main screen click to view the unit parameters and set the decrements Function keys Press and hold to enter unit mode settings Under settings screen press to confirm the parameters and return to the main screen 4 3 3 3 LED Status Description LED display Description PV Green Light PV start charging OFF PV stop charging LINE Green Light AC is connected and the output is...

Страница 6: ...3 3 4 2 Main Menu From the main screen press and hold Function key for 5 seconds to enter the main menu press DOWN or UP to view the sub menu The function of P0 P1 P2 P3 P4 when flashing is as follows Main Menu Functions P4 Buzzer mode P3 Inverter charging current P2 P1 Inverter operating mode P0 Save Exit 7 ...

Страница 7: ... UP key and press the Function key to save and exit On Indicates that the buzzer is on 0FF Indicates that the buzzer is off 3 3 5 2 Inverter AC Charging Settings In the main screen press and hold the Function button for 5 seconds to enter the main menu Press the DOWN button to select inverter charging information P3 Press the Function button to enter the setting interface through DOWN or UP keys i...

Страница 8: ... When the grid power is back to normal the unit will transfer back to grid power bypassing 03 Battery priority mode Under working mode 03 grid power is not charging the battery The unit can be charged via Solar charger only as Solar and battery are the main power sources Solar charge the batteries and supply the power to the loads through the inverter When the battery is discharged to the low volt...

Страница 9: ...ion Battery The external battery s voltage must be consistent with the unit s internal battery voltage 51 2V Make sure the positive and negative terminals are wired correctly Reversing polarity may damage the unit 4 5 Instructions for AC Input The unit has 2 ways for AC input wiring AC Input Socket and AC input terminals Please check below for details 13 WARNING VERY IMPORTANT DO NOT connect AC In...

Страница 10: ...AC input terminals is 30A 14 When you want to use the unit as an uninterrupted backup power to your loads you are suggested to wire the AC input with terminals Use the correct size of AC power cable 2 5mm or bigger make sure the AC power voltage is in the range of unit allowance Turn on AC input breaker and battery breaker THEN wire AC power source to the AC input terminals VERY IMPORTANT NOTE DO ...

Страница 11: ...ds are connected to the 5VDC Output USB souckets on the front panel The total 5VDC USB output current is 2A The 12VDC loads is connected to the 12VDC Output on the front panel The total 12VDC output current is 2A Make sure the positive and negative of the DC loads are wiring correctly before plug in DC output short circuit may cause the unit damage 17 AC Output MAX 15A AC Output MAX 12VDC LOAD 5VD...

Страница 12: ...l relay action the unit AC output is off LCD screen turned off turn off all the breakers 5 4 Battery protection table When the AC output is turned on the relevant protections must beexecuted when the battery voltage reaches the value in the table below Inverter protection voltage parameters Overvoltage protection Overvoltage recovery Low voltage alarm Low voltage protection 71 6VDC 68 2VDC 46 0VDC...

Страница 13: ...ies of product requires little maintenance battery only needs to maintain its charge for full life expectancy 6 2 If you do not use the equipment for a long period of time it is recommended it be charged every 4 6 months Under normal circumstances the battery s life will be 3 5 years if found in poor condition you must replace the battery early Replacement of the battery must be carried out by qua...

Страница 14: ...ether the wiring of the Solar array is correct and the contact is reliable When you contact the service staff please provide the following information Type of unit date of issue complete description of the problem including the relevant indicator display status battery configuration connection 22 8 Technical Data Sheet Model 3KW Battery rated voltage vdc 51 2 Inverter Rated power w 3000 Input volt...

Отзывы: