Страница 1: ...Instruction Manual 12 8V 100Ah SB2220 Lithium Slimline Deep Cycle Battery with Metal Case ...

Страница 2: ...ࢉFDWLRQ 5 2 Battery Usages 6 2 1 Charge 6 2 2 Discharge 6 3 Battery Service Environment 6 4 Special Attention 7 5 Battery Use and Maintenance 9 5 1 Battery Storage 9 5 2 Battery Check Before Use 9 5 3 Battery Installation 9 5 4 Battery Operating Requirements 10 5 5 Battery Operation 10 5 6 Battery Troubleshooting 11 6 Products Disclaimer 12 ...

Страница 3: ...cautions When Working With Batteries Consider your access to emergency medical attention and work safely Use caution to eliminate the risk of dropping a metal tool on the battery It could spark or short circuit the battery or other electrical parts and could cause an explosion Insulated tools are strongly recommended anytime you are working around batteries 1HYHU VPRNH RU DOORZ D VSDUN RU ࢊDPH QHD...

Страница 4: ...arge Current 50A Nominal Discharge Current 100A safe Max Pulse Discharge Current 150A 10S Operating Temp Charge 0 45 C Discharge 10 55ºC Storage Temp 10 45xºC 60 80 SOC Storage Capacity 1C rate 0 2C 100Ah Inverter Disconnect High 15V Inverter Disconnect Low 12 5V 1 2 Product Parameter Graph 100 95 90 85 80 75 0 1000 E 4S1P 12V100Ah DOD Cycles 0 2C 25 2000 3000 4000 5000 6000 7000 8000 Number of Cy...

Страница 5: ...LRQ ȁ If the battery s voltage drops below permissible levels the BMS will disconnect itself automatically To recover from a low voltage shutdown remove the load from the battery At this point the battery should be charged immediately If the battery does not start on its own you may need to put a charger on the battery If the battery is so discharged that the Low Voltage Shutdown cannot be cleared...

Страница 6: ...5 ৰ 352 8 7 1 DWWHU 3DUW GHQWLࢉFDWLRQ Carry Handle Display Charge 14 6V 50A MAX Discharge 14 6V 50A MAX Discharge 14 6V 120A MAX Remaining Battery Switch test battery status Battery Capacity Voltage ...

Страница 7: ...ve connections as indicated on the battery case Battery discharge ambient temperature is 10 C 55 C When the ambient temperature 45 C please pay attention to the ventilation and heat dissipation Charging temperature is 0 C 45 C Ambient humidity RH is d 3D DWWHQWLRQ WR HOLPLQDWH PRLVWXUH ZKHQ WKH DPELHQW KXPLGLW LV RQGHQVDWLRQ RQ WKH VXUIDFH of the battery should be avoided ...

Страница 8: ...weld the battery connections Do not pierce the battery with a nail or other sharp objects R QRW XVH WKH EDWWHU LQ DQ ORFDWLRQ ZKHUH VWDWLF HOHFWULFLW DQG PDJQHWLF ࢉHOG LV strong Doing so may be damage the battery protection circuit Do not overload the battery Do not alter the circuit board This could damage the internal circuits and cause battery failure Do not deform or damage the outside of the ...

Страница 9: ...rom charging and stop use of the battery immediately Remove and isolate the battery from loads and charging sources and contact your battery supplier or distributor The terminals of any discarded battery should be covered to reduce any potential safety hazard Reversing the positive and negative terminals during charging will damage the circuit board Do NOT reverse polarity ...

Страница 10: ...occur due to poor wiring connections to the charger or the loads 5 3 Battery Installation Please install the battery to ensure minimal dust metal or other foreign PDWHULDOV 1R VPRNLQJ RU ࢉUH GXULQJ LQVWDOODWLRQ YRLG D VKRUW FLUFXLW RI WKH battery to prevent equipment damage or personal injury The battery should be installed in a well ventilated space with no direct sunlight Do not install where it...

Страница 11: ...s slightly to prevent an a possible over discharged state Letting a battery sit for months without this procedure can lead to battery problems Contact your installer or distributor for more information about this procedure Don t use organic solvents to clean the battery case A battery is a consumable product with limited cycle life Please replace it before the diminished capacity can t meet the ne...

Страница 12: ...rged normally Battery Disconnection Solution Battery is powered but no voltage is present Contact your installer or distributor DWWHU KDV VXࢃHUHG D FROOLVLRQ DQG KDV GDPDJH WR WKH FDVH RU KDV DQ HOHFWURO WH RGRU Solution It s not in the end user to repair a damaged battery Contact your installer or distributor QVXࢄFLHQW FDSDFLW Solution KDUJH IXOO DQG GLVFKDUJH WR 62 WKH EDWWHU ZLWK a F FOHV Batte...

Страница 13: ...orrect use installation connection or input output power inconsistent with this manual may cause damage to product Improper use or installation can lead to battery damage and possible damage to the structure the battery is housed and cause injury The manufacturer and distributors are not responsible for incorrectly installed or used batteries The manufacturer or distributors are not responsible fo...

Страница 14: ...13 ...

Страница 15: ...14 ...

Страница 16: ...Distributed by Electus Distribution Pty Ltd 320 Victoria Rd Rydalmere NSW 2116 Australia www electusdistribution com au Made in China ...