background image

 

 

Version 1.3-130603 

14 

low-input voltage warnings and shutdowns. This is due to the DC voltage 

drop in the cables from the battery to the inverter. 

 

The longer and narrower the cables, the greater the voltage drops. 

                                                                                                                                        

WARNING! 

              DC wiring terminations.   

              Ensure all the DC connections and terminations are 

secure and tight. Loose connection can cause 

overheating and fire. 

 

The following table recommends the cable size for optimum inverter 

performance. 

 

SU Series 

Wire AWG  Inline Fuse 

Description 

MI5703 

#12 

25A 

Black 1M + Red 1M 

MI5702 

#10 

25A*2 

MI5704 

#6 

30A*4 

MI5712 

#4 

25A*6 

MI5706 

30A*6 

MI5708 

#2 

30A*8 

MI5710 

#1 

25A*12 

 

Lay the flexible earth cable from the earthing point of the vehicle to the 

earthing point of the inverter. 

 

If cables are to be fed through metal walls or walls with sharp edges, use 

glands or proper bushings to prevent cable damage. 

 

Do not lay cables that are loose or bent next to electrically conductive 

materials. 

 

 

Содержание MI5700

Страница 1: ...Version 1 3 130603 0 Pure Sine Wave DC TO AC Power Inverter User s Manual ...

Страница 2: ...cations 2 2 Important Safety Guidelines and Instructions 3 4 3 Features 4 4 Applications and Descriptions 5 5 Introduction and Operation 6 14 6 Mechanical Drawings 15 18 7 Trouble Shooting 19 8 Maintenance 19 9 Warranty 20 ...

Страница 3: ...0 92 91 91 91 91 93 Protection High Temperature Short Circuit Over Load Input Voltage Load Control Load 95 100 Alarm but remain working Load 105 Alarm then after 1 minute shut down Load 120 Alarm then after 5 seconds shut down Operating temperature range 20 40 Operation Humidity 20 90 RH Storage Temp Humidity 30 70 10 90 RH Intelligent Design Heat Auto Control Fans slow speeding up 38 3 Fans start...

Страница 4: ...g may occur The inverter must be kept in a safe place out of the reach of children Make sure that the device is properly secured To avoid a risk of fire and electronic shock make sure that existing wiring and terminations are in good electrical condition secure and not undersized Do not operate the inverter with damaged or substandard wiring If the fuse blows or protection fails parts of the inver...

Страница 5: ...ark or short circuit on the battery of other electrical part may cause an explosion Remove personal metal items such as rings bracelets necklaces and watches when operating with lead acid batteries These are electrically conductive devices and may cause short circuit and very high temperature resulting in personal injury USB supply output DC 5V 500mA 3 Features Pure Sine Wave output with THD 3 Adv...

Страница 6: ... lamp etc Power tools circular saws drills grinders sanders buffers weed and hedge trimmers air compressors etc Office equipment computers printers cash registers monitors facsimile machines scanner etc Household appliances vacuum cleaners fans fluorescent and incandescent lights shavers sewing machines Kitchen appliances coffee makers small refrigerators blenders ice markers toasters etc Home ent...

Страница 7: ...peration Make sure the inverter power switch is in the OFF position Connect the inverter to a fully charged battery Use the ON OFF switch to turn the inverter ON or OFF Connect the electric appliance to AC output socket of the inverter Turn the inverter ON the Green LED should light up indicating power is on and inverter is functional Appliance can now be used When finished turn inverter power swi...

Страница 8: ...is adjustable and set by the Dip Switch SW1 and SW2 Setting this mode reduces the inverter s standby power consumption if the applied AC load is below the set threshold in the table below After setting the DIP switches you must restart the inverter Noted these are nominal values only and may vary MI5700 MI5702 MI5703 MI5704 MI5706 MI5708 MI5710 MI5712 SW1 SW2 No Saving No Saving OFF OFF 20W 30W OF...

Страница 9: ...r rating of the inverter LED Indicators INV POWER Power on normal operation Green LED OVER LOAD Over load Red LED OVER TEMP Over temperature Yellow LED Green LED LED Show Status Solid __________ Normal Red LED LED Show Status Solid __________ Over Load Slow Blink __ __ __ Battery High voltage Fast Blink Battery Low voltage Yellow LED LED Show Status Solid __________ Over Temperature ...

Страница 10: ...9 5 3 Rear Panel Operations SONDAR R SONDAR R SONDAR R SONDAR R ...

Страница 11: ... airflow DC Input Terminals Connect DC terminals to a battery or battery bank with appropriate voltage for the inverter being used WARNING Reverse polarity connection will blow the internal fuse and may damage the inverter permanently POS Represents positive terminal NEG Represents negative terminal Connect the and cables from the battery to the respective terminals of the inverter Ground connecti...

Страница 12: ...on Model Over Voltage Low Voltage Alarm Low Voltage High voltage Shut down Restart Low voltage Shut down Restart 12V 15 1V 14 5V 10 6V 10V 12 5V 24V 30 1V 29V 21 2V 20V 25V Over Temperature Protection 65 56 Shut down Restart Model Over Load Protection 1 min Shut down 5 sec Shut down MI5700 190W 220W MI5702 380W 430W MI5703 380W 430W MI5704 820W 950W MI5706 1250W 1320W MI5708 1600W 1800W MI5710 MI5...

Страница 13: ...o times slowly Low Battery Protection BEEP two times fast High Battery Protection BEEP two times fast long beeps Heat Protection BEEP one time long beeps __ __ __ __ Load Control Alarm Stage 1 BEEP three times Slowly Load Control Alarm Stage 2 BEEP three times at medium rate Load Control Alarm Stage 3 BEEP three times fast ...

Страница 14: ...ve cable lengths Do not install the inverter in the same compartment as batteries Use the recommended wire lengths and sizes Do not mount the inverter where it will be exposed to the gases from the batteries as prolonged exposure will damage the inverter WARNING Shock Hazard Before proceeding carefully check that inverter is NOT connected to any batteries and that all wiring is disconnected from a...

Страница 15: ...e The following table recommends the cable size for optimum inverter performance SU Series Wire AWG Inline Fuse Description MI5703 12 25A Black 1M Red 1M MI5702 10 25A 2 MI5704 6 30A 4 MI5712 4 25A 6 MI5706 30A 6 MI5708 2 30A 8 MI5710 1 25A 12 Lay the flexible earth cable from the earthing point of the vehicle to the earthing point of the inverter If cables are to be fed through metal walls or wal...

Страница 16: ...15 6 Mechanical Drawings SONDAR R SONDAR R I N V PO W ER O VER LO AD O VER TEM P ...

Страница 17: ...Version 1 3 130603 16 SONDAR R ...

Страница 18: ...17 SONDAR R ...

Страница 19: ...Version 1 3 130603 18 ...

Страница 20: ...ink slowly Low battery voltage or high battery voltage Check battery voltage charger battery check DC cable terminations No AC power output Yellow LED blink slowly Over temperature shut down Check if there is proper ventillation Check if there are any objects or barriers blocking the vents or fans 8 Maintenance To keep your inverter operating properly there is very little maintenance required Make...

Страница 21: ...Warranty does not cover parts such as external case fuses connectors input leads etc Our goods come with guarantees that cannot be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of accep...