![PowerTech KIT PL1000 Скачать руководство пользователя страница 21](http://html.mh-extra.com/html/powertech/kit-pl1000/kit-pl1000_manual_1591632021.webp)
19
INSTRUCTIONS PL600/PL1000
● F3 function settings:
Logic F3-1
The reactions of the photocells when detecting obstacles
Gate Status
Photocell 2
Photocell 1
Photocell 1/ Photocell 2
Closed
Stop opening
No effect
Stop opening
Open
No effect
Reloads automatic closing time
Stop during moving
Stop opening
Reloads automatic closing time
Closing
No effect
Open
Locks and, on release, reverses to open
Opening
Closes the leaf
No effect
Locks and, on release, continues opening
Logic F3-2
The reactions of the safety edge/ photocell when detecting obstacles
Gate Status
Safety Edge
Photocell 1
Closed
Stop opening
No effect
Open
Reloads automatic closing time
Stop during moving
Stop opening/ closing
Reloads automatic closing time
Closing
Reverses to open for 2 seconds
Open
Opening
Reverses to close for 2 seconds
No effect
Logic F3-3
The reactions of the loop detector/ photocell when detecting obstacles
Gate Status
Loop Detector
Photocell 1
Closed
Open
No effect
Open
Reloads automatic closing time
Stop during moving
Open
Reloads automatic closing time
Closing
Open
Open
Opening
Open
No effect
4.2.1 Programmable Functions of LED Display
LED Display
Programmable Functions
“N-L”: The PL600 system learning is not done.
“RUN”: The PL600 system is in normal performing.
“LEA”: Enter learning mode and then wait for learning instructions.
The operation of gate learning:
(1). Press “SET” one time; then press “SET” + “DOWN” for 3seconds, and the LED display
shows “LEA” ; and then press the transmitter (A) button one time. After 1~3seconds, the LED
display shows “ARN”
“ARN”: The system learning is in progress.
The Auto-learning process of
gate moving: “Gate open to the end- stop close to the end- stop.