background image

 

RIF

8

00

  

Indoor Repeater for 

8

00

 MHz

User Manual 

 

 

 
 
 
 

 

  

 

 
 

 

 

 

Powertec Telecommunications Pty Ltd
14/511 Olsen Ave
Southport QLD 4215
Australia
Tel: +61 7 5577 0500
Fax: +61 7 5577 0599

Email: [email protected]
Web: www.powertec.com.au 

Содержание RIF800

Страница 1: ...ndoor Repeater for 800 MHz User Manual Powertec Telecommunications Pty Ltd 14 511 Olsen Ave Southport QLD 4215 Australia Tel 61 7 5577 0500 Fax 61 7 5577 0599 Email sales powertec com au Web www powertec com au ...

Страница 2: ...ECIFICATION 3 2 MECHANICAL SPECIFICATION 3 3 ALARM SPECIFICATION 4 4 SYSTEM AUTO SHUTDOWN ALGORITHM 4 5 SYSTEM AUTO LEVEL CONTROL ALGORITHM 4 6 SYSTEM OPERATION 5 7 SYSTEM INSTALLATION 7 8 TROUBLE SHOOTING 10 9 HANDLING PROCEDURES 10 ...

Страница 3: ...1Tone IMD 2Tone 7dBm 45dBc Over 45dBc Over Impedance 50ohm Supply Power DC 9V 3 5A from AC 100 240V Adaptor RF Connector Type SMA Female ALC ON Level Meter ON Internal Repeat system RF IF 2 Mechanical Specification Characteristic Unit mm Remark Size 227 158 33 5 D W H 3 Alarm Specification Characteristic Specification Remark Over Power Uplink Downlink external Input signal over 30dBm System Auto S...

Страница 4: ...Shutdown 61 62sec Shutdown status clear check for the status for 1sec 63 122sec Shutdown 123 124sec Shutdown status clear check for the status for 1 sec After Repeat Program verification available upon request 5 System Auto Level Control Algorithm ALC Automatic Level Control operates at 1dB step to maintain the output level of 10dBm when the input signal is from 60dBm to 30dBm 30dB range ...

Страница 5: ... areas such as offices shops and basement car parks in the GSM band with frequencies that are programmable to the specific requirements of each site It is small lightweight and easy to install Simply plug it in and the coverage will be immediately extended The uplink and downlink gain of the repeater can be adjusted by ALC 10 10dB dBm m Repeat eater ...

Страница 6: ...ernal Constitution 1 Outdoor Antenna Cable Link Port SMA Female 2 Indoor Antenna Cable Link Port SMA Female 3 DC Input Terminal Jack 4 DC Power ON OFF S W 5 Status Display LED POWER ALARM FWD LEVEL 6 BRACKET ...

Страница 7: ...VICE ANT 1SET OPTION 6 DONOR ANT CABLE 1SET OPTION 7 SERVICE ANT CABLE 1SET OPTION 8 SCREWS Installation Process This is one of the most important process in repeater installation as how to install the antenna decides performance of this equipment 1 Decide a place to install the outdoor antenna considering the cable length of the donor antenna 2 Attach the antenna bracket at the wall Refer image A...

Страница 8: ...eater Bracket Placement 4 Check the Receiving Signal by DONOR CABLE and connect to repeater s DONOR ANT PORT Input Signal Receive Range 30 60dBm 5 Install the service antenna at the appropriate place and connect the cable with the repeater 6 Connect the adaptor to the repeater and check the POWER LED power on status ...

Страница 9: ...ED ON Operation Instruction Upon confirmation of electric power 100 240V AC insert AC cable to power supply then using DC cable insert power cable to DC power input terminal which is set on the bottom of the equipment LED Configuration Power DC Power is normal Green LED ON Alarm FEW REV over power When Shut Down Red LED ON FWD Level FWD Down Link Indicates output Level Green LED ON OFF No of LEDs ...

Страница 10: ... ON 1 Check the Isolation between Donor ANT and Service ANT When no LED blinks at FWD LEVEL LED Check the FWD Input Power level whether it is in normal range 9 Handling Procedures Please avoid using the other Power Supply besides included ones Prohibited to use other frequencies antennas Please refrain from installing the equipments reach of children ...

Отзывы: