background image

4

ASSEMBLY

GROUNDING INSTRUCTIONS

     WARNING

Improper connection of equipment grounding conductor 
can result in the risk of electrical shock. Equipment 
should be grounded while in use to protect operator from 
electrical shock. 
•  Check with a qualified electrician if you do not 

understand grounding instructions or if you are in doubt 
as to whether the tool is properly grounded. 

•  This tool is equipped with an approved cord rated at 

120V and a 3-prong grounding type plug (see Figure 4) 
for your protection against shock hazards. 

•  Grounding plug should be plugged directly into a  

properly installed and grounded 3-prong grounding type 
receptacle, as shown (see Figure 4). 

Properly Grounded Outlet

3-Prong Plug

Grounding Prong

Figure 4

•  Do not remove or alter grounding prong in any manner. 

In the event of a malfunction or breakdown, grounding  
provides a path of least resistance for electrical shock. 

     WARNING

Do not allow fingers to touch the terminals of plug when 
installing or removing from outlet. 
•  Plug must be plugged into matching outlet that is 

properly installed and grounded in accordance with 
all local codes and ordinances. Do not modify plug 
provided. If it will not fit in outlet, have proper outlet 
installed by a qualified electrician.

•  Inspect tool cords periodically, and if damaged, have 

repaired by an authorized service facility.

•  Green (or green and yellow) conductor in cord is the 

grounding wire. If repair or replacement of the electric 
cord or plug is necessary, do not connect the green (or 
green and yellow) wire to a live terminal.

EXTENSION CORDS 

•  The use of an extension cord is not recommended. 

The use of any extension cord will cause some drop in 
voltage and loss of power. 

•  Wires of the extension cord must be of sufficient size to 

carry the current and maintain adequate voltage. 

•  Use the table to determine the minimum wire size 

(A.W.G.) extension cord. 

•  Use only 3-wire extension cords having 3-prong 

grounding type plugs and 3-pole receptacles which 
accept the tool plug. 

•  If the extension cord is worn, cut or damaged in any  

way, replace it immediately. 

Extension Cord Length

Wire Size…………….. A.W.G. 
Up to 50 ft…………… 14 gauge

NOTE: Using extension cords over 50 ft. long is not 
recommended.

MOTOR

The dust collector is assembled with motor and wiring 
installed. The electrical wiring schematic is shown in 
Figure 5.
The permanently split capacitor motor has the following 
specifications:
Horsepower (Peak HP) .................................................. 1
Voltage ............................................................... 120/240
Amp ......................................................................... 7/3.5
Hertz ............................................................................ 60
Phase .................................................................... Single
RPM ......................................................................... 3450

ELECTRICAL CONNECTIONS

     WARNING

All electrical connections must be performed by a qualified 
electrician. Make sure tool is off and disconnected 
from power source while motor is mounted, connected, 
reconnected or anytime wiring is inspected. Motor and 
wires are installed as shown in wiring schematic (See 
Figure 5). Motor is assembled with approved, 3-conductor 
cord to be used at 120 volts.

Figure 5

The power lines are inserted directly into the switch. The
green ground line must remain securely fastened to the 
frame to properly protect against electrical shock. The 
power supply to the motor is controlled by a single pole 
locking rocker switch.
• Remove the key to prevent unauthorized use.

Содержание DC5370

Страница 1: ...eed this manual for safety instructions operating procedures and warranty Put it and the original sales invoice in a safe dry place for future reference Wall Mount Dust Collector QUESTION 1 847 780 6120 Visit us on the web at www powertecproducts com ...

Страница 2: ...micron Overall Dimensions 20 x 18 x 45 508 x457 x 1143 mm Weight 52 lbs 23 6 kg TABLE OF CONTENTS PRODUCT SPECIFICATIONS SAFETY RULES 1 Work Preparation Work Area Preparation Tool Maintenance Tool Operation ASSEMBLY 2 Unpacking Installation Test Power Source Grounding Instructions Extension Cords Motor Electrical Connections OPERATION 5 Basic Operations MAINTENANCE 6 General Maintenance Cleaning L...

Страница 3: ...ous environments Do not use power tools in damp or wet locations Do not expose power tools to rain Work area should be properly lit Proper electrical receptacle should be available for tool Three prong plug should be plugged directly into properly grounded three prong receptacle Extension cords should have a grounding prong and the three wires of the extension cord should be of the correct gauge K...

Страница 4: ...ws nails or other metal parts Always wear approved eye protection and respirator when emptying collection filter bags Never operate the dust collector with all blast gates closed Turn machine off disconnect power cord and ensure all moving parts have stopped completely before changing or emptying the bags ALWAYS ensure collection filter bags are secured in place Do not place your hand or tools nea...

Страница 5: ... serious personal injury Run a test to ensure the dust collector operates properly 1 Ensure all tools are removed from the work area and the wall mounting bracket is secure 2 Plug the power cord into the correct receptacle Refer to Power Source paragraph in this section of the manual 3 Turn the dust collector ON Refer to On Off Switch paragraph in Operation section of the manual 4 If unusual noise...

Страница 6: ...o not connect the green or green and yellow wire to a live terminal EXTENSION CORDS The use of an extension cord is not recommended The use of any extension cord will cause some drop in voltage and loss of power Wires of the extension cord must be of sufficient size to carry the current and maintain adequate voltage Use the table to determine the minimum wire size A W G extension cord Use only 3 w...

Страница 7: ...tor is not in use Place it in a safe place and out of reach of children WARNING ALWAYS lock the switch OFF when the dust collector is not in use Remove the key and keep it in a safe place In the event of power failure blown fuse or tripped circuit breaker turn the switch OFF and remove the key preventing accidental startup when power comes on OPERATION 5 Figure 6 Yellow Switch Key On Off Switch Op...

Страница 8: ...fficiency when the collection bag is empty This collection bag has a clear window and a bottom zip The clear window allows operator to see the amount of dust in the bag and the bottom zip makes bag emptying easy MAINTENANCE 6 MAINTENANCE 6 LUBRICATION The sealed bearings in the motor have been permanently lubricated at the factory They require no further lubrication MACHINE STORAGE When the dust c...

Страница 9: ...oose broken 3 Unit is incorrectly mounted to wall 4 Motor fan is rubbing cover 5 Motor bearings faulty 1 Inspect replace any stripped or damaged bolts nuts and re tighten 2 Tighten replace 3 Tighten replace mounting hardware 4 Replace fan cover replace loose damaged fan 5 Call the customer service line at 847 780 6120 for assistance Loud repetitious noise or excessive vibration coming from dust co...

Страница 10: ...asher 1 6 DC5370006 Spring washer 1 4 1 7 DC5370007 Cap screw M6 x 30 1 8 DC5370008 Phillip HD tp screw M5 x10 12 9 DC5370009 Motor gasket 1 10 DC5370010 Flat washer 1 4 x 18 4 11 DC5370011 Hex screw 1 4 x 1 2 4 12 DC5370012 Motor plate 1 13 DC5370013 Wall mount bracket 1 14 DC5370014 Flange bolt 1 4 x 1 2 4 15 DC5370015 Cap 1 1 16 DC5370016 Handle cover 1 17 DC5370017 Set screw 5 16 x 5 16 1 18 D...

Страница 11: ...e proof of purchase documentation which includes a date of purchase POWERTEC will either repair or replace any defective part at our option at no charge to you The repaired or replacement unit will be covered by the same limited warranty for the balance of one year warranty period WHAT IS NOT COVERED This warranty applies to the original purchaser at retailer and may not be transferred This warran...

Страница 12: ...Southern Technologies LLC Waukegan IL 60087 ...