INSTALLATION

Refer to Figure 1 to 8

This air filtration system is specifically designed to circulate 
and filter non-metallic dust, which is generated throughout 
the work area. The unit can be located on a work bench, 
hung from an overhead support or mounted to the ceiling 
or wall. When selecting a location ensure the power 
source is easy to access. Ensure the remote control is 
within 65 feet of the control panel with no obstructions.

IMPORTANT

: When determining a location for the air 

filtration system, always select a location where the air 
flow is unrestricted. Locate the unit away from corners and 
any heating or cooling vents.

     CAUTION

 

The air filtration system is too heavy to be lifted by one 
person. Obtain assistance from others before trying to lift 
or move.

Remove the Shipping Blocks

Refer to Figures 2 -3

Styrofoam shipping blocks are installed around the motor 
to prevent damage during shipping. These MUST be 
removed before operation.
•  Lift up on the clips located at the top and bottom of the 

cabinet and remove the outer filter.

•  Pull the inner filter from the cabinet. 
•  Remove the four Phillips head screws securing the inner 

grate and remove the inner grate.

•  Remove the shipping blocks and replace the inner grate.

Figure 2  

Inner Grate

Screws

Screws

Figure 3  

Shipping 

Block

Shipping 

Block

ASSEMBLY

3

 • Follow the instructions under 

Changing the Filters

 to 

replace the filters correctly.

Work Bench Location

Tools required for assembly:

 None

     CAUTION

 

Clamp the air filtration system in place if using on a work 
bench or sawhorse, if not permanently mounting the unit.
•  With assistance, carefully turn the air filtration 

system over.

•  Use the double sided tape to attach the four rubber feet 

to the four bottom corners of the unit. (Figure 4)

•  With assistance, carefully turn the air filtration 

system over.

•  Place the air filtration system onto a work bench, ensure 

the air flow is not restricted and the unit is away from 
corners and any heating or cooling vents.

•  Plug the power cord into the correct receptacle. 

(Refer to 

Power Source 

paragraph in this section of 

the manual.)

Figure 4  

Rubber Feet

Rubber Feet

Содержание AF1045

Страница 1: ...r safety instructions operating procedures and warranty Put it and the original sales invoice in a safe dry place for future reference 20 0805 Visit us on the web at powertecproducts com QUESTION 1 84...

Страница 2: ...Speed 63 dB MOTOR SPECIFICATIONS This air filtration system is supplied with a 1 5 HP motor installed The 120 Volt AC universal motor has the following specifications Motor Amperage 3A Voltage 120 Her...

Страница 3: ...your workshop childproof with padlocks master switches or remove switch keys to prevent any unintentional use of power tools 1 SAFETY RULES TOOL MAINTENANCE Turn the machine OFF and disconnect the ma...

Страница 4: ...n 1 M6 Bolts include bolt flat washer and lock washer mounting bracket assembly 4 M6 Eye Bolts 4 Flange Nuts eye bolt assembly 4 Rubber Feet 4 Double Sided Tape Rubber Feet Assembly 1 Owner s Manual n...

Страница 5: ...up on the clips located at the top and bottom of the cabinet and remove the outer filter Pull the inner filter from the cabinet Remove the four Phillips head screws securing the inner grate and remove...

Страница 6: ...o right and 24 1 2 from front to rear With assistance raise and secure the air filtration system eye bolts to the four hanging lines Figure 7 Anchor not supplied Chain Cable or Steel Strapping Lines n...

Страница 7: ...t fingers to touch the terminals of plug when installing or removing from outlet Inspect tool cords periodically and if damaged have it repaired by an authorized service facility The conductor with in...

Страница 8: ...e HI LED light will illuminate to indicate the selected speed FILTRATION TIMING NOTE The filtration timing can ONLY be controlled with the remote The TIMER button controls the timer setting The 1 HR 2...

Страница 9: ...filter The arrow on the outer filter indicates the air flow direction ensure the filter is positioned properly Figure 13 Clip Inner Outer Arrow REMOTE CONTROL BATTERY REPLACEMENT Remove the battery co...

Страница 10: ...ck circuit for proper voltage 2 Motor capacitor has failed 2 Replace motor capacitor 3 Control panel circuit board has failed 3 Inspect or replace control panel circuit board System has vibration or i...

Страница 11: ...NOTE 9 NOTES...

Страница 12: ...AIR FILTRATION SYSTEM PARTS ILLUSTRATION 10 PARTS LIST 10...

Страница 13: ...g Washer 6 mm 14 24 1045 024 Flat Washer 6 mm 10 25 1045 025 Housing 1 26 1045 026 Mounting Bracket 4 27 1045 027 Hex Head Bolt M6X12 8 Key Part Description Qty 28 1045 028 Handle 2 29 1045 029 Flange...

Страница 14: ...rranty service you must present the proof of purchase documentation which includes a date of purchase POWERTEC will either repair or replace any defective part at our option at no charge to you The re...

Страница 15: ...NOTE...

Страница 16: ...Southern Technologies LLC Waukegan IL 60087...

Отзывы: