Page 4  — English

IMPORTANT SAFETY INSTRUCTIONS

SPECIFIC SAFETY RULES

 

Use only authorized replacement parts and accessories 
and follow instructions in the 

Maintenance

 section of this 

manual. Use of unauthorized parts or failure to follow 
maintenance instructions may create a risk of shock or 
injury.

 

Maintain the unit per maintenance instructions in this 
Operator’s Manual.

 

Inspect the unit before each use for loose fasteners, fuel 
leaks, etc. Replace damaged parts.

WARNING:

When this generator is used to supply a building 
wiring system:

 generator must be installed by a 

qualified electrician and connected to a transfer switch 
as a separately derived system in accordance with 
NFPA 70, National Electrical Code. The generator shall 
be connected through a transfer switch that switches 
all conductors other than the equipment grounding 
conductor. The frame of the generator shall be connected 
to an approved grounding electrode. Failure to isolate the 
generator from power utility can result in death or injury 
to electric utility workers. 

 

Do not use this generator to provide power for emergency 
medical equipment or life support devices.

 

This generator has a neutral floating condition. This means 
the neutral conductor is not electrically connected to the 
frame of the machine.

 

Exhaust contains poisonous carbon monoxide, a color-
less, odorless gas. Breathing exhaust can cause loss 
of consciousness and can lead to death. If running in a 
confined or partially-enclosed area, the air may contain 
a dangerous amount of carbon monoxide. To keep ex-
haust fumes from building up, always provide adequate 
ventilation.

 

Always use a battery-powered carbon monoxide detec-
tor when running the generator. If you begin to feel sick, 
dizzy, or weak while using the generator, shut it off and 
get to fresh air immediately. See a doctor. You may have 
carbon monoxide poisoning.

 

Place the generator on a flat, stable surface with a slope 
of no more than 4°.

 

Operate in a well-ventilated, well-lit area isolated from 
working areas to avoid noise interference.

 

Operating the generator in wet conditions could result in 
electrocution. Keep the unit dry.

 

Keep the generator a minimum of 3 feet away from all 
types of combustible material. 

 

Do not operate generator near hazardous material.

 

Do not operate generator at a gas or natural gas filling 
station.

 

Do not touch the muffler or cylinder during or immediately 
after use; they are HOT and will cause burn injury.

 

Do not allow the generator’s gas tank to overflow when 
filling. Fill to 1 in. below the top neck of the gasoline tank 
to allow for fuel expansion.

 

Do not smoke when filling the generator with gasoline.

 

Shut down the engine and allow to cool completely before 
adding gasoline or lubricant to the generator.

 

Do not remove the oil dipstick or the fuel tank cap when 
the engine is running.

 

Pay close attention to all safety labels located on the 
generator.

 

Keep children a minimum of 10 feet away from the gen-
erator at all times.

 

The unit operates best in temperatures between 23°F and 
104°F with a relative humidity of 90% or less.

 

Operating voltage and frequency requirement of all 
electronic equipment should be checked prior to plug-
ging them into this generator. Damage may result if the 
equipment is not designed to operate within a +/- 10% 
voltage variation, and +/- 3 hz frequency variation from 
the generator name plate ratings. To reduce the risk of 
damage, always have an additional load plugged into the 
generator if solid state equipment (such as a television 
set) is used. A power line conditioner is recommended 
for some solid state applications.

 

For outdoor use only.

 

Save these instructions. Refer to them frequently and use 
them to instruct others who may use this product. If you 
loan someone this product, loan them these instructions 
also.

Содержание PS903250 Series

Страница 1: ...r lagarant a WARNING To reduce the risk of injury the user must read and understand the operator s manual before using this product ADVERTENCIA Para reducir el riesgo de lesiones el usuario debe leer...

Страница 2: ...See this fold out section for all of the figures referenced in the operator s manual Consulte esta secci n desplegable para ver todas las figuras a las que se hace referencia en el manual del operado...

Страница 3: ...por del tanque de combustible M Ground terminal terminal de conexi n a tierra N Fuel valve v lvula de combustible O Circuit breaker disyuntor de circuito A Analog hour meter hor metro anal gico B Fuel...

Страница 4: ...de aceite varilla medidora de aceite B Oil fill hole agujero de llenado de aceite A B A Fuel tank tanque de combustible A A Fuel valve v lvula de combustible B Recoil starter grip mango del arrancado...

Страница 5: ...latch pestillo de filtro de aire B Air filter cover tapa del filtro de aire C Air filter filtro de aire D Air filter unit unidad del filtro de aire A Oil drain plug perno de drenaje de aceite B Oil c...

Страница 6: ...d the nut and tighten the nut fully Connect the other end of the wire securely to a suitable ground source that is in contact with the soil for a minimum distance of 8 ft The National Electric Code co...

Страница 7: ...se this unit Do not start or operate the engine in a confined space building near open windows or in other unventilated space where dangerous carbon monoxide fumes can collect Carbon monoxide a colorl...

Страница 8: ...sh air immediately See a doctor You may have carbon monoxide poisoning Place the generator on a flat stable surface with a slope of no more than 4 Operate in a well ventilated well lit area isolated f...

Страница 9: ...e extremely flammable and explosive Fire or explosion can cause severe burns or death Hot Surface To reduce the risk of injury or damage avoid contact with any hot surface Lifting Hazard To reduce the...

Страница 10: ...a home or garage EVEN IF doors and windows are open Only use OUTSIDE and far away from windows doors and vents You WILL be KILLED or SERIOUSLY HURT if you do not follow the Operator s Manual instruct...

Страница 11: ...start fires around dry vegetation A spark arrestor may be required The operator should contact local fire agencies for laws or regulations relating to fire prevention requirements Risk of Fire Check f...

Страница 12: ...to estimate the watts required to start electric motors however if an electric motor fails to start or reach running speed turn off the appliance or tool immediately to avoid equipment damage Always...

Страница 13: ...he generator and or electrical devices connected to it ELECTRICAL POWER MANAGEMENT To prolong the life of the generator and attached devices it is important to take care when adding electrical loads t...

Страница 14: ...is turned on and off using the fuel valve GROUND TERMINAL The ground terminal is used to assist in properly grounding thegeneratortohelpprotectagainstelectricalshock Consult with a qualified local ele...

Страница 15: ...ardous condition leading to possible serious personal injury WARNING Do not attempt to operate the generator until assembly is complete Failure to comply could result in possible serious personal inju...

Страница 16: ...the risk of shock or electrocution Consult a qualified electrician electrical inspector or local agency having jurisdiction for local codes or ordinances to find out if grounding is needed in your sit...

Страница 17: ...event serious personal injury and property damage handle gasoline with care Keep away from ignition sources handle outdoors only do not smoke while adding fuel and wipe up spills immediately NOTICE Th...

Страница 18: ...un for 15 30 seconds then move the choke to the RUN position STOPPING THE ENGINE See Figure 11 To stop the engine under normal operating conditions Remove any load from the generator Turn the fuel val...

Страница 19: ...r Replace with a new air filter Replace the air filter cover and latch to secure NOTE Do not run the generator without the air filter Rapid engine wear will result CHANGING ENGINE LUBRICANT See Figure...

Страница 20: ...system drain the fuel from the tank and carburetor before storing DRAINING THE FUEL TANK Turn the fuel valve to the OFF position Remove the fuel line from the petcock by squeezing the ends of the ret...

Страница 21: ...generator is used in dusty areas When generator has exceeded the maximum figures specified in the table maintenance should still be cycled according to the intervals of time or hours stated herein STO...

Страница 22: ...terelement Cleanor replace as needed Drain fuel and carburetor Refuel with fresh gasoline If problem continues contact your nearest authorized service center AC receptacle does not work Circuit breake...

Страница 23: ...Rope Engine Brushes Cotter Pins Wheels Warranty is voided if the customer fails to install maintain and operate the product in accordance with the instruc tions and recommendations of the Company as...

Страница 24: ...arranty rights and responsibilities you should call our parts and technical support group toll free number below or E mail to us Theemissionwarrantyisadefectswarrantyanddefectsarejudged on normal engi...

Страница 25: ...rra a un ngulo de a lo sumo 45 Si aun as la jabalina se encuentra con el estrato rocoso se la puede enterrar en una trinchera de al menos 75 cm 30 pulg de profundidad En cualquier caso el extremo supe...

Страница 26: ...que utilicen esta unidad ni os ni personas carentes de la debida instrucci n para su manejo No haga arrancar o funcionar el motor en un espacio confinado de edificio cerca de ventana abiertas o en otr...

Страница 27: ...ienza a sentirse mal mareado o d bil al estar utilizando el generador ap guelo y respire aire fresco de inmediato Vea a un doctor Puede sufrir intoxicaci n por mon xido de carbono Coloque el generador...

Страница 28: ...s vapores del mismo son extremadamente inflamables y explosivos El fuego o una explosi n pueden causar quemaduras graves e incluso la muerte Superficie caliente Para reducir el riesgo de lesiones corp...

Страница 29: ...Corriente Hz Hertz Frecuencia ciclos por segundo W Watt Potencia hrs Horas Tiempo gal Gal n Volumen qt Cuarto Volumen You WILL be KILLED or SERIOUSLY HURT if you do not follow the Operator s Manual in...

Страница 30: ...nflamable o combustible directamente en la trayectoria de las emanaciones del escape PARACHISPAS El uso de este equipo puede producir chispas propensas a iniciar incendios cerca de vegetaci n seca Es...

Страница 31: ...el cord n A 120 V A 240 V Conduct 8 Conduct 10 Conduct 12 Conduct 14 Conduct 16 2 5 300 600 305 m 1000 pies 183 m 600 pies 114 m 375 pies 76 m 250 pies 5 600 1200 152 m 500 pies 91 m 300 pies 61 m 200...

Страница 32: ...los dispositivos el ctricos co nectados al mismo ASPECTOS EL CTRICOS 1 Sin equipos conectados al generador ponga en marcha el motor de la manera que se describe posteriormente en este manual 2 Enchuf...

Страница 33: ...ctamente el generador como ayuda de protecci n contra descargas el ctricas Consulte con un electricista local calificado con respecto a los requisitos de conexi n a tierra en el rea geogr fica donde s...

Страница 34: ...peligrosa y como consecuencia posibles lesiones corporales graves ADVERTENCIA No intente accionar el generador antes de terminar de armarlo De lo contrario puede ocurrir un riesgo de lesiones graves...

Страница 35: ...e otra forma podr a ser necesario ponerlo a tierra para reducir el riesgo de descargas el ctricas o electrocuci n Antes de usar el generador consulte a un electricista calificado un inspector el ctric...

Страница 36: ...uras se recomienda el aceite SAE 10W 30 Siempre utilice lubricante para motor de cuatro tiempos que satisfaga o sobrepase los requisitos SJ de clasificaci n de servicio API NOTA Ellubricantesindeterge...

Страница 37: ...onar el motor seis veces como m ximo NOTA No permita que el mango se retraiga violentamente despu sdearrancar regr selosuavementeasulugaroriginal Permita que el motor funcione 15 a 30 segundos y despu...

Страница 38: ...r un desempe o ptimo de la unidad reemplace el filtro de aire por lo menos una vez al a o Vea la Lista de piezas de repuesto para conocer los tama os disponibles y los n meros de pieza de estos elemen...

Страница 39: ...incendios locales estatales y federales Consulte a las autoridades que correspondan P ngase en contacto con el servicio al cliente para comprar un parachispas de repuesto Revise si el parachispas tie...

Страница 40: ...enimiento debe ser mayor si se el generador se usa en zonas de mucho polvo Si el generador ha sobrepasado los valores m ximos especificados en el cuadro aun debe seguirse el programa de mantenimiento...

Страница 41: ...alidad Compruebe el elemento de filtro de aire Limpie o reemplace seg n sea necesario Vac e el combustible y el carburador Reabastezcadegasolinafrescalaunidad Sielproblemacontin a comun quesecon un ce...

Страница 42: ...uerda del arrancador retr ctil escobillas del motor pasadores de chaveta ruedas La garant a queda anulada si el cliente no instala mantiene o utiliza el producto respetando las instrucciones y las rec...

Страница 43: ...rechos y obligaciones en virtud de la garant a comun quese con la l nea gratuita de nuestro grupo de asistencia t cnica y repuestos el n mero figura a continuaci n o escr banos por correo electr nico...

Страница 44: ...na placa o etiqueta pegada a la caja del motor Le recomendamos anotar el n mero de serie en el espacio suministrado abajo N MERO DE MODELO_______________________ N MERO DE SERIE_______________________...

Отзывы: