12
4.2.2
Recommended minimum clearances for
servicing
Should it be necessary to service the Powerstar electric
water heater, observe the following clearances. These
are not required clearances, but would facilitate any
service work.
Fig. 5
Recommended minimum clearances
4.3
Mounting the water heater
B
Undo the retaining screws on the front cover and take
the cover off the heater. Hold the back plate in
position against the wall and mark the four mounting
holes.
B
Drill the holes and secure the heater using the four
wood screws supplied.
Fig. 6
Vertical mounting position
AE115
AE125
Top (A)
12"
12"
Sides
0"
0"
Bottom (B)
6"
6"
Front (C)
12"
12"
Tab. 6
Recommended minimum clearances
WARNING:
B
The heater must only be installed in the
orientation shown in Fig. 6 i.e., mounted
in a vertical position with the water
fittings located at the bottom of the
heater.
Under no circumstances should
the heater be mounted differently.