7. STATUS INDICATOR AND BEEPER

SAFEGUARD provides status indicator through three
LEDs located at side of the product as well as audible
beep. The indications are shown below.

8. BATTERY REPLACEMENT

SAFEGUARD has user replaceable batteries. Please read 

following warnings and instruction carefully before 

proceeding with the battery replacement. 

1) 

  Remove watches, rings, or other metal objects. 

2) 

Use tools with insulated handles. 

3) 

Wear rubber gloves and boots. 

4) 

Do not lay tools or metal parts on top of batteries. 

5) 

Turn off UPS (Make sure all indicators are off) 

6) 

Turn off mains (AC supply) 

7) 

Disconnect AC input cord from the mains

 

TURN the unit over and Remove 
the screws located on the bottom 
of the UPS to open the battery 
cover. 

LIFT the battery out of its 
compartment and disconnect first 
the Red and then the Black wire 
connecting it to the UPS. Replace 
the same type of battery. 

Slide the battery compartment 
cover back to close the battery 
housing. 

9. TROUBLE SHOOTING

Check Power Shield FAQ web page or phone technical
support for an assistance with a problem that cannot be
resolved using the trouble shoot table below:

10. Product specification

ITEM 

SPECIFICATION 

INPUT 

240Vac Nominal 

Capacity 

750VA/450W 

Voltage 

240VAC 

Voltage Range 

177-290VAC 

OUTPUT 

Voltage Regulation 

±10% 

Transfer Time 

Typical 2-6ms, 10ms max. 

Waveform 

(Battery Mode) 

Simulated Sine Wave 

BATTERY 

Type & Number 

12V/9AH x 1 

Recharge Time 

4 hours recover to 90% capacity 

Dimension, 

(DXWXH)mm 

292 x 199 x 91 (Foot included) 

Net Weight (Kg) 

5.88 

OPERATION ENVIRONMENT 

Humidity 

0-90% RH @ 0- 40°C 

(non-condensing) 

Noise Level 

Less than 40dB 

INTERFACE 

USB Port 

Supports Windows 98 SE/ME/NT 

4.x/2000/2003/XP/Vista/2008 

11. Warranty and Service

WARRANTY CONDITIONS
The standard warranty is two (2) years from the date of
purchase. Power Shield’s standard procedure is to
replace the original unit with a factory reconditioned unit.
Power Shield will ship the replacement unit once the
defective unit has been received by the service
department, or cross ship upon the receipt of a valid
credit card number. The customer pays for shipping the
unit to Power Shield. Power Shield pays ground freight
transportation costs to ship the replacement to the
customer within Australia capital cities metro areas only

WARRANTY CLAIMS

First please follow the troubleshooting procedure
described above. If you are unable to solve your
problem then please call 1300-305-393. You will be
required to provide the following details
The model number, serial number, and the date
purchase of the UPS. Be prepared to troubleshoot the
problem over the telephone with technical support. If
unsuccessful the technical support will issue a
Returned Material Authorization Number & Warranty
Procedure Document. Our technical support personnel
will also guide you through the process

------------------------------------------------------------------------- 

WARRANTY 

REGISTRATION 

VERY IMPORTANT 

In order to validate your warranty it is essential that you 

register it. Warranties must be registered online 

Please register your warranty by visiting 

www.powershield.com.au 

STATUS 

Green LED 

Yellow LED 

Red LED 

Beeper 

On line Operation 

Solid on 

Off 

Off 

No Beep 

On battery Operation 

Off 

Solid on 

Off 

2 beeps every 30 sec 

Low battery status 

Off 

Flashing 

(1 flashing 

every 1sec) 

Off 

Rapid beep 

  ( one second intervals) 

On line Overload 

Solid on 

Off 

Solid on 

Constant beeping 

On battery overload 

Off 

Solid on 

Solid on 

Constant beeping 

Bad battery detected 

Flashing 

(1 flashing 

every 1sec) 

Off 

Flashing 

(1 flashing 

every 1sec) 

Constant beep 

Internal Fault 

Off 

Off 

Solid on 

Constant beeping 

Unit performing Battery test via 

software 

Flashing 

(1 flashing 

every 1sec) 

Solid on 

Off 

No Beep 

Problem 

Probable Cause 

Solution 

The UPS will not turn on. 

Battery is disconnected or utility power is 
not available at the wall outlet. 

Connect the battery and ensure power is 
available at the wall outlet. Ensure that 
the UPS is turned on 

Yellow LED is on, and 2 beeps 
every 30 seconds. But mains are 
normal. 

UPS is not connected properly to the 
mains. 

Connect the UPS according to the 
installation guide. 

Circuit breaker has tripped 

Reset circuit breaker on the UPS 

UPS shutdown after a few 
seconds and circuit breaker has 
tripped. 

UPS output is short-circuited, possibly 
due to defective equipment. 

Disconnect your computer from the UPS 
and then reset the breaker. 

Inadequate runtime 

Battery is not fully charged. 

Charge the unit at least 4 hours. 

Battery is near the end of useful life. 

As a battery ages, the amount of runtime 
available will decrease. Replace battery. 

PHYSICAL 

PROTECTION

 

Surge Protection

468 Joules / 11000A