background image

ENGLISH INSTRUCTIONS

Warranty

The Seller warrants that the equipment manufactured by it and cover

ed by this order 

or contract is free fr

om defects in material and workmanship and, without charge,

 

equ

ipmen

t fo

und 

to b

e de

fec

tive

 in 

mate

rial

 or 

work

mansh

ip w

ill b

e re

paired

, or 

at 

Seller’s option r

eplaced F .O.B. original point of shipment, if written notice of failur

e is 

received by Seller within one (1) year after date of shipment (unless specifically noted 

elsewhere), pr

ovided said equipment has been properly installed, operated in accor

-

dance with the Seller’s instructions, and pr

ovided such defects are not due to abuse or 

decomposition by chemical or galvanic action. THIS EXPRESS W

ARRANTY IS IN LIEU 

OF AND EXCLUDES ALL OTHER WARRANTIES, GUARANTEES, OR REPRESENT

A-

TIONS, EXPRESS OF IMPLIED. THERE ARE NO IMPLIED WARRANTIES OF MER

-

CHANTABILITY 

OR OF FITNESS 

FOR A PAR

TICULAR PURPOSE.

 The 

Seller assumes 

no responsibility for r

epairs made on the Seller’s equipment unless done by the Seller’

authorized personnel, or by written authority fr

om the Seller. The Seller 

makes no guar-

antee with respect to material not manufactur

ed by it.

Garantía

El Vendedor garantiza que los equipos fabricados por él y cubiertos por esta or

den o 

contrato están libres de defectos en los materiales y mano de obra y que los equipos 

con materiales 

o mano 

de obra 

defectuosos serán 

reparados 

sin car

go o, 

a opción 

del 

Vendedor

, reemplazados F

.O.B. en el punto original de envío, si el Vendedor r

ecibe una 

notificación por escrito de falla en el lapso de un (1) año después de la fecha de envío 

(a menos que se especifique en otra parte), siempre y cuando dichos equipos 

hayan 

sido correctamente instalados y utilizados de conformidad con las instrucciones del

 

Vendedor

, y siempre que dichos 

defectos no se deban a maltrato o descomposición 

por acción química o galvánica.  ESTA GARANTÍA EXPRESA REEMPLAZA Y EXCLUYE 

CUALQUIER OTRA GARANTÍA, GARANTÍA GRATUIT

A O PROMESA, EXPRESAS O 

IMPLÍCITAS. NO EXISTEN GARANTÍAS IMPLÍCIT

AS DE COMERCIALIZACIÓN O DE 

IDONEIDAD PARA UN PROPÓSITO 

EN PAR

TICULAR. El V

endedor no asume ninguna 

responsabilidad por las r

eparaciones hechas a los equipos del Vendedor salvo que

 

se realicen por personal autorizado por el V

endedor o con autorización escrita del 

Vendedor

. El Vendedor no otor

ga ninguna garantía con respecto a los materiales no

 

fabricados por él.

Garantie

Le vendeur 

garantit que 

l'équipement fabriqué 

par lui 

et couvert 

en vertu 

de cette 

commande ou de ce contrat est exempt de vices de matériau et de fabrication 

et, dans 

l'éventualité ou 

de tels 

vices de 

matériau ou 

de fabrication 

se manifes

-

teraient, il sera répar

é sans frais ou, à la discrétion du vendeur

, remplacé franco 

à bord (F

AB) de son point d'expédition d'origine (sauf si spécifié ailleurs), pourvu 

que ledit équipement ait été installé correctement et utilisé conformément aux

 

instructions du 

vendeur et, 

pourvu que de 

tels vices ne 

soient pas 

le résultat 

d’une 

utilisation abusive 

ou d'une 

décomposition découlant 

d'une réaction 

chimique ou 

galvanique. LA PRÉSENTE GARANTIE EST EXPRESSE, REMPLACE ET EXCLUT 

TOUTE AUTRE GARANTIE OU REPRÉSENTATION EXPRESSE OU IMPLICITE.

 

IL N’EXISTE AUCUNE GARANTIE TACITE DE QUALITÉ MARCHANDE OU

 

D’ADAPTATION À UN BUT P

ARTICULIER. Le vendeur n’assume aucune r

espon-

sabilité pour des réparations ef

fectuées sur son équipement à moins qu'elles aient 

été effectuées par du personnel autorisé par lui ou par une autorisation écrite de 

lui. Le vendeur n’offr

e aucune garantie pour les matériaux non fabriqués par lui.

USA: 

T: (800) 669-5430 • F: (847) 229-0526 • PowersControls.com

 

Canada: 

 T: (905) 332-4090 • F: (905) 332-7068 • PowersControls.ca 

Latin America: 

 T: (52) 81-1001-8600 • F: (52) 81-8000-7091 • PowersControls.com

IS-P-LM495  1645 

    EDP# 6511208 

© 2016 Powers

Estados Unidos: 

T: (800) 669-5430 • F: (847) 229-0526 • PowersControls.com

 

Canadá: 

 T: (905) 332-4090 • F: (905) 332-7068 • PowersControls.ca 

Latinoamérica: 

 T: (52) 81-1001-8600 • F: (52) 81-8000-7091 • PowersControls.com

S-P-LM495  1645 

    EDP# 6511208 

© 2016 Powers

É.-U. : 

T: (800) 669-5430 • F: (847) 229-0526 • PowersControls.com

 

Canada : 

 T: (905) 332-4090 • F: (905) 332-7068 • PowersControls.ca 

Amérique latine : 

 T: (52) 81-1001-8600 • F: (52) 81-8000-7091 • PowersControls.com

IS-P-LM495  1645 

    EDP# 6511208 

© 2016 Powers

NOTICE

Flush all pipes thoroughly before installation. Installation and  field adjustment are the responsi-

bility of the installer.

Installation Instructions

1.  Locate suitable place for the tempering valve. Valves should be accessible for service and 

adjustment, and be as close to the point of use as possible.

2.  Bleed pressure from the system.
3.  Route copper tubing or piping to fit valve dimensions.
4.  For valves with Quick-Connect tailpieces refer to “Quick-Connect Installation” instructions 

below.  

5.  Remove tailpieces from the valve and make sure union nuts are over the tubing/piping before 

connecting to the 

tailpiece.

NOTICE

If soldering, remove 

unions and gaskets 

from valve body prior 

to soldering to prevent 

damage to valve from 

excessive heat.
6.  Flush piping again, 

install valve using 

filter gasket on 

hot and cold water 

inlets and fiber 

gasket on mixed 

water outlet.

7.  Turn on the cold 

and hot water. 

If any leaks are 

observed, tighten 

connections as 

necessary to stop 

leak before pro-

ceeding.

Troubleshooting

Fluctuating or erratic hot water temperature at fixture:

   Unbalanced Pressure. Install balancing or throttling valve at the hot and cold 

water supplies and adjust accordingly for demand.

Hot water backing up into cold water line:

   Hot water pressure is higher than cold water pressure. Examine check valves for 

dirt & debris, clean as necessary.

Cannot adjust water temperature to desired temperature:

   Install balancing or throttling valve at the hot and cold water  

supplies and adjust accordingly for demand.

High pressure drop through the tempering valve:

   Valve undersized. Install larger thermostatic tempering valve.

Insufficient hot water during peak demand:

   Check flow requirement during peak demand period. Use larger thermostatic tem-

pering valve.

Series LFLM495

 

HydroGuard

®

Thermostatic Tempering Valves

Válvulas termostáticas de mezclado

Vannes thermostatiques

IS-P-LM495

To Adjust Temperature (Figure 3)

1.   Let the water flow for at least two minutes to 

allow supply temperature to stabilize.

2.   Place a thermometer in the outlet water 

stream.

3.   Loosen handle screw with hex wrench.
4.    Handle must be lifted 1⁄4” to adjust tempera-

ture. Rotate handle clockwise to decrease 

temperature and counter-clockwise to 

increase the temperature.

5.   Lower handle and tighten screw.
6.   Check for outlet temperature. 

NOTICE

Pressure Differential between Hot & Cold Water Supplies 

must be less then 25%.

NOTICE

It is recommended that shutoff valve(s) be installed on the inlet(s) to facilitate service of 

the LFLM495 valve.

Local building or plumbing codes may require modifications to the information 

provided. You are required to consult the local building and plumbing codes prior to 

installation. If the information provided here is not consistent with local building or 

plumbing codes, the local codes should be followed. This product must be installed by 

a licensed contractor in accordance with local codes and ordinances.

WARNING

WARNING

!

WARNING

!

Read this Manual BEFORE using this equipment.

Failure to read and follow all safety and use information can result 

in death, serious personal injury, property damage, or damage to the 

equipment.

Keep this Manual for future reference.

WARNING

!

Need for Periodic Inspection and Yearly Maintenance:  

Periodic inspection and 

yearly maintenance by a licensed contractor is required. Corrosive water condi-

tions, temperatures over 200°F, unauthorized adjustments or repair could render 

the valve ineffective for service intended. Regular checking and cleaning of the 

valve’s internal components and check stops helps assure maximum life and proper 

product function. Frequency of cleaning and inspection depends upon local water 

conditions.

WARNING

!

FAILURE TO COMPLY WITH PROPER INSTALLATION AND MAINTENANCE 

INSTRUCTIONS COULD CONTRIBUTE TO THE VALVE FAILURE, RESULTING IN 

INJURY AND/OR DEATH.
TO ENSURE THE ACCURATE AND RELIABLE OPERATION OF THIS PRODUCT, IT IS 

ESSENTIAL TO:

•    Properly design the system to minimize pressure and temperature variations.
•    This valve is not factory preset and can be adjusted to deliver scalding tempera-

tures. 

Check outlet temperature to ensure it does not exceed 105°F (41°C). 

Make sure temperature limit stop is properly re-set to maximum 105°F (41°C) 

following valve maintenance or repair. Tampering with limit stop in any way may 

result in scalding temperature causing serious bodily harm and/or death.

Installation Instructions • Instrucciones de instalación • Instructions d’installation

WARNING:

 This product contains chemicals known to the 

State of California to cause cancer and birth defects or 

other reproductive harm.

For more information: Watts.com/prop65

ADVERTENCIA: 

Este producto contiene sustancias químicas 

que en el Estado de California se conocen como causantes de 

cáncer y malformaciones u otros daños reproductivos.

Para más información: W

atts.com/prop65

AVER

TISSEMENT : 

Ce produit contient des produits chimiques 

reconnus par l’État de Californie comme étant cancérigènes et 

pouvant provoquer des anomalies congénitales ou affecter la 

capacité de reproduction.

Pour plus d'informations : W

atts.com/prop65

LFLM495-5

LFLM495-1

Advanced Thermal  

Activation

Repair Kit 

Model

Part #

Description

LFLM495

495 100 

Plunger/Motor Assembly

Turn

Hotter

Hex Wrench

Colder

Unscrew, Lift Cap

to Adjust

Figure  3.    

Quick-Connect Installation

1.  Mark pipe as shown.  

This is pipe insertion 
depth.

2. Clean pipe end.

  To Connect

3.  If using PEX tubing, 

insert pipe stiffener 
(provided) into end 
of pipe.

4.  Push tubing into tail-

piece up to mark.

5. Insert collet clip.

PEX tubing only

Pipe Stiffener

Tail Piece

Mark

Collet clip

1

1

/

2

 in. (38.1mm)

1

3

/

4

 in. (44.45mm)

1

7

/

8

 in. (47.63mm)

3

/

4

 in.Pipe (19.05mm)

1 in.Pipe (25.4mm)

1

/

2

 in.Pipe (12.7mm)

1. Remove collet clip.

  To Disconnect

2. Depress collet.
3. Pull tubing from tailpiece.

Collet depressed

WARNING

!

For valves with CPVC or PEX end connections, do not exceed the tubing manufacturers pressure and 

temperature ratings. Refer to the tubing manufacturers product specifications for that information. 

Figure 1. 

Typical  
ASSE 1069 
Application

Cold

Hot

LFLM495

Mixed

COLD WATER

SUPPLY

POWERS SERIES LM495 OR 

LFLM495 WITH INTEGRAL 

CHECKS AND SCREENS

HOT WATER SUPPLY

Figure 2.

Single/Two 
Handle Faucet 
Application

Отзывы: