PowerPoint P174NGXSS Скачать руководство пользователя страница 6

CONNECTION DIAGRAM

Caution! Voltage of heating elements 220-240V

 

Caution! In the event of any connection the safety 

wire must be connected to the

PE terminal. 

Recommended 

type of 

connection 

lead

 

N

L

PE

Fig. 9

 

GAS CONNECTION (RGI qualified personnel only)

The appliance has an G 1/2" threaded pipe connector to connect it to the gas 

system.  Please ensure that the connection is made using a rigid pipe.

When making the gas connection, it is important to place the gasket (A) in 

between the inlet pipe (C) and the elbow (B) to ensure a tight gas seal (Fig. 8).

ELECTRICAL CONNECTION

The appliance must be connected to the mains supply by a qualified gas 

engineer using fixed wiring via a double pole switched fused spur outlet protected by a 3A fuse and with 

a contact separation of at least 3mm in all poles. We recommend that the appliance is connected by a 

qualified electrician who is a member of the N.I.C.E.I.C. and will comply with I.E.T. and local regulations. 

The wires in the mains lead are coloured in accordance with the following code: Green & Yellow = 

Earth,  Blue = Neutral, Brown = Live.    

A

B

C

D

M

NATURAL GAS TO LPG CONVERSION

This conversion must only be carried out by a competent person (i.e. a Gas Safe registered fitter). 

Instructions to fit replacement injectors: 

1. Disconnect the appliance from the gas and electrical supplies. 

2. Remove burner components “B” and pan supports (Fig. 9). 

3. Remove the injectors “A” (Fig. 9) with a socket spanner and replace with the corresponding injectors.

Setting up minimum flow rates: 

1. Turn on the LPG supply, light the burners and turn the controls to the minimum position as indicated 

by the small flame symbol. 

2. Remove the control knobs “M” (Fig. 10). 

3. Insert a small screwdriver “D” (Fig. 10) into the hole at the top of the tap “C” and turn the adjustment 

screw left or right until the flame of the burner is conveniently regulated to the low position. 

4. Make sure when turning quickly from maximun position to minimum position that the flame does not 

extinguish.

5. Replace the knobs “M”.

 Fig. 8

B

A

C

N

L

Fig. 10

4

1

1

2

2

2

3

4

2

5

Содержание P174NGXSS

Страница 1: ...BUILT IN GAS HOB INSTALLATION AND USER INSTRUCTIONS Note Do not use the hob until you have read the instruction manual P175NGXSS P174NGXSS ...

Страница 2: ...the hob or place combustible materials on or near the surface even when the hob is not in use 10 Do not fill deep fat frying containers more than one third full of oil and NEVER leave unattended 11 Before cleaning the hob switch off at the mains 12 When cooking is finished switch off all controls and allow to cool 13 These appliances are not intended for use by persons including children with redu...

Страница 3: ...ary gas Material Flame failure device Power Supply Size mm Built in mm Type 580x500x90 680x500x90 Yes Yes Rapid gas burner Semi rapid gas burner 557x477 557x477 3 5kW 3 5kW 1 75kW 1 0kW 1 0kW 3 0kW 1 75kW Stainless steel Stainless steel AC 220 240V 50HZ P175NGXSS P174NGXSS Even if you have used a gas hob before it is important that you read these instructions thoroughly before using the appliance ...

Страница 4: ...cuation device It shall be installed and connectd in accordance with current installation regulations Particular attention shall be given to the relevant requirements regarding ventilation INSTALLATION LOCATION The appliance may be located in a kitchen kitchen diner or utility room however it cannot be in a room containing a bath or shower The hob must not be installed in a bed sitting room of les...

Страница 5: ...entilation for example opening of a window or more effective ventilation for example increasing the level of machanical ventilation where present CAUTION Accessible parts may be hot when the grill is in use Young children should be kept away CAUTION This appliance is for cooking purposes only It must not be used for other purposes for example room heating When fitting a gas hob above a drawer or a...

Страница 6: ...with I E T and local regulations The wires in the mains lead are coloured in accordance with the following code Green Yellow Earth Blue Neutral Brown Live A B C D M NATURAL GAS TO LPG CONVERSION This conversion must only be carried out by a competent person i e a Gas Safe registered fitter Instructions to fit replacement injectors 1 Disconnect the appliance from the gas and electrical supplies 2 R...

Страница 7: ...ibly to promote sustainable re use of material resources To return your unwanted product please use local return and collect systems or contact the retailer where the product was purchased They should be able to take the appliance for environmentally safe recycling SELECT THE RIGHT BURNER Use an appropriately sized pan with a flat bottom for each burner see the table below and Fig 12 When the cont...

Страница 8: ...cy of this gas hob was tested and measured according to EN 30 2 1 1998 A1 2003 A2 2005 The semi rapid burner and rapid burner were tested separately the auxiliary burner is not required for test because its nominal heat input is less than 1 16kW The energy efficiency of the gas burners and the hob were calculated according to COMMISSION REGULATION EU No 66 2014 B Rational use of the energy and the...

Страница 9: ... the 1 year guarantee the appliance must have been used according to the instructions supplied Exclusions Shomar Ltd shall not be liable to replace or repair the goods under the terms of the guarantee where The fault has been caused or is attributable to accidental use misuse negligent use or used contrary to the manufacturer s recommendations or where the fault has been caused by power surges or ...

Страница 10: ...werPoint Appliances is located at the offices of the Brand owner and Distributor Shomar Ltd Unit 9 Western Industrial Estate Dublin 12 Republic Of Ireland Helplines office hours Spare Parts contact number is 01 450 5327 or email service shomar ie 9 ...

Отзывы: