OPERATING INSTRUCTIONS

TYPICAL INSTALLATION

To begin using the tool:

1.  As a standard practice, drain water from the air compressor  

  tank and air lines prior to use each day (reference your 

  compressor operators manual for detailed instructions).
2.  Install a 1/4” NPT male connector (not included) into the air  

  inlet port on the tool (see Figure 2). 

Note: Use Teflon® Tape  

  on all threaded connections.

3.  Turn on the air compressor and allow it to build up pressure.

4.  Adjust the air compressor’s regulator or the supply line 

  regulator to 90 PSI.

 

Always make sure the tool is disconnected  

from any air supply before changing the grinding stones or 

accessories, or serious injury could occur.

Grinders will attain extremely high R.P.M. or free speed. Use only accessories that are  

rated with R.P.M. equal to or greater than the no-load free speed of your tool.

Inspect each grinding stone for cracks or chips prior 

to mounting. DO NOT use a grinding stone that is chipped, cracked or 

damaged in any other way.

5.  Select the desired grinding stone or accessory. 

NOTE: This tool is  

  equipped with a 1/4” collet chuck, which uses grinding stones and  

  accessories with a 1/4” spindle. For grinding stones or accessories  

  with a 1/8” spindle, the 1/4” collet chuck needs to be replaced with  

  a 1/8” collet chuck (included with the tool).

 

To change the grinding stones or accessories:

    a.  Loosen the collet chuck with the collet wrenches (included with your  

      tool) by placing one collet wrench on the flats of the grinder shaft 

      to hold it from turning. Place the other collet wrench on the flats of 

      the collet chuck and turn counter-clockwise to loosen (see figure 3).
    b.  Insert a grinding stone or accessory into the collet chuck, then turn the  

      collet chuck clockwise to tighten using the collet wrenches.

  

Make sure the grinding stone or accessory spindle is  

fully inserted into the collet chuck opening and the collet chuck is 

securely tightened. Loose attachments could fly off during operation and cause serious injury.

 

    c.  After mounting a grinding stone or accessory, hold the grinder under a workbench and run it for at least  

      60 seconds to be sure the grinding accessory is secure. Make sure no one (including the operator) is in  

      the perating plane of the grinding accessory.

 Key

Description

Key

Description

Key

Description

Key

Description

A Air hose

D In-line Oiler

G Quick Coupler

J Female Connector

B In-line Filter

E Air Hose 

H Male Connector

K Spray Gun

C Tee Fitting

F Whip Hose 

I Air Tool

Figure 1

Figure 2

To loosen

To Tighten

Figure 3

A Exhaust port

B Trigger

C Teflon tape

D Male connector

E Air inlet port

F Grinder shaft

G Collet chuck

Содержание P024-0292SP

Страница 1: ...ecomendado de manguera 3 8 Presi n m xima de trabajo 90 PSI Read and understand all safety precautions in this manual before operating Failure to comply with instructions in this manual could result i...

Страница 2: ...ing grinding drilling and other construction activities contains chemicals known to the State of California to cause cancer birth defects or other reproductive harm Some examples of these chemicals ar...

Страница 3: ...K OF BURSTING AND OR INJURY Check for misalignment or binding of moving parts breakage of parts and any other condition that affects the tool s operation If damaged have the tool serviced before using...

Страница 4: ...8 spindle the 1 4 collet chuck needs to be replaced with a 1 8 collet chuck included with the tool To change the grinding stones or accessories a Loosen the collet chuck with the collet wrenches inclu...

Страница 5: ...moving parts USER MAINTENANCE INSTRUCTIONS TROUBLESHOOTING GUIDE SYMPTOM POSSIBLE CAUSE S CORRECTIVE ACTION Tool will not run or runs slowly Grit in tool tool gummed up No oil in tool Low air pressure...

Страница 6: ...epairs replacements or adjustments to the equipment or any costs for labor performed by the purchaser without the Company s prior written approval The effects of corrosion erosion and normal wear and...

Страница 7: ...a construction contiennent des produits chimiques connus de l tat de la Californie qui peuvent tre l origine de cancers ou avoir une toxicit vis vis de la reproduc tion Voici quelques exemples de tels...

Страница 8: ...NT ET OU DE BLESSURE V rifiez l alignement et le d gagement des pi ces mobiles l tat des pi ces et toute autre condition pouvant influer sur le fonc tionnement de l outil Si un outil est endommag fait...

Страница 9: ...aut remplacer le mandrin pince par celui de 3 mm 1 8 po fourni avec l outil Pour remplacer une meule ou un accessoire a Desserrez le mandrin pince l aide des cl s de pince fournies avec l outil en pla...

Страница 10: ...s Remarque Gardez la serviette l cart des pi ces mobiles ENTRETIEN PAR L UTILISATEUR GUIDE DE D PANNAGE SYMPT ME CAUSES POSSIBLES MESURE CORRECTIVE L outil ne tourne pas ou tourne lentement Particules...

Страница 11: ...des r parations remplacements ou r glages du mat riel ou des co ts de main d oeuvre de l acheteur sans le consentement pr alable par crit de la Soci t Les effets de la corrosion de l rosion et de l us...

Страница 12: ...ades como lijar pulir taladrar y otras actividades de construcci n contienen qu micos que se ha determinado para el Estado de California que causan c ncer defectos cong nitos u otros da os reproductiv...

Страница 13: ...ramienta es peligrosa en manos de usuarios sin capacitaci n RIESGO DE ESTALLAR Y O DE LESI N Verifique que no haya partes movibles mal alineadas o atascadas partes rotas y cualquier otra condici n que...

Страница 14: ...as de 1 4 por una boquilla de mordazas de 1 8 incluida con la herramienta Para cambiar piedras afiladoras o accesorios a Afloje la boquilla de mordazas con las pinzas de boquillas incluidas con la her...

Страница 15: ...m viles INSTRUCCIONES DE MANTENIMIENTO DEL USUARIO GU A DE SOLUCI N DE PROBLEMAS S NTOMAS POSIBLES CAUSAS MEDIDA CORRECTIVA La herramienta no funciona o funciona despacio Hay polvo en la herramienta l...

Страница 16: ...NTIAS IMPLICITAS INCLUYENDO LA GARANTIA DE COMERCIABILIDAD Y APTITUD PARA UN PROPOSITO PARTICULAR ESTAN EXCLUIDAS POR ESTE MEDIO LA RESPONSABILIDAD POR DA OS EMERGENTES O INCIDENTALES BAJO CUALQUIERA...

Отзывы: