2

Owner’s Manual for Portable Generator

• For safety reasons, it is recommended that

the maintenance of this equipment be per-

formed by an IASD. Inspect the generator

regularly, and contact the nearest IASD for

parts needing repair or replacement.

Exhaust and Location Hazards

• If you start to feel sick, dizzy, or weak after

the generator has been running, move to

fresh air IMMEDIATELY. See a doctor, as

you could have carbon monoxide poison-

ing.

(000179a)

DANGER

The exhaust system must be properly maintained. Do 
not alter or modify the exhaust system as to render it 
unsafe or make it noncompliant with local codes and/or 
standards. Failure to do so will result in death 
or serious injury.

(000104)

DANGER

Electrocution. Water contact with a power source, 
if not avoided, will result in death or serious injury.

(000116)

DANGER

Electrocution. Turn utility and emergency
power supplies to OFF before connecting power 
source and load lines. Failure to do so will result 
in death or serious injury. 

(000146)

WARNING

Equipment and property damage. Do not alter  
construction of, installation, or block ventilation for  
generator. Failure to do so could result in unsafe  
operation or damage to the generator.

(000178a)

Asphyxiation. Always use a battery operated carbon 
monoxide alarm indoors and installed according to 
the manufacturer’s instructions. Failure to do so 
could result in death or serious injury.

WARNING

(000250)

WARNING

Equipment and property damage. Do not operate unit on  
uneven surfaces, or areas of excessive moisture, dirt, dust  
or corrosive vapors. Doing so could result in death, serious  
injury, property and equipment damage.

(000111)

WARNING

Moving Parts. Keep clothing, hair, and appendages
away from moving parts. Failure to do so could 
result in death or serious injury.

(000108)

WARNING

Hot Surfaces. When operting machine, do not 
touch hot surfaces. Keep machine away from 
combustables during use. Hot surfaces 
could result in severe burns or fire.

(000142)

Do not insert any object through the air cooling slots.
Generator can start at any time and could result in 
death, serious injury, and unit damage.

WARNING

WARNING

Risk of injury. Do not operate or service this 
machine if not fully alert. Fatigue can impair the 
ability to service this equipment and could result 
in death or serious injury.

(000215)

WARNING

Injury and equipment damage.  Do not use 
generator as a step. Doing so could result in falling, 
damaged parts, unsafe equipment operation, 
and could result in death or serious injury.  (000216)

CAUTION

(000291)

Equipment damage. Do not attempt to start or operate 
a unit in need of repair or scheduled maintenance. 
Doing so could result in serious injury, death, or 
equipment failure or damage.

WARNING

000406

(000103)

DANGER

Asphyxiation. Running engines produce carbon 
monoxide, a colorless, odorless, poisonous gas. 
Carbon monoxide, if not avoided, 
will result in death or serious injury.

(000179a)

DANGER

The exhaust system must be properly maintained. Do 
not alter or modify the exhaust system as to render it 
unsafe or make it noncompliant with local codes and/or 
standards. Failure to do so will result in death 
or serious injury.

(000146)

WARNING

Equipment and property damage. Do not alter  
construction of, installation, or block ventilation for  
generator. Failure to do so could result in unsafe  
operation or damage to the generator.

(000178a)

Asphyxiation. Always use a battery operated carbon 
monoxide alarm indoors and installed according to 
the manufacturer’s instructions. Failure to do so 
could result in death or serious injury.

WARNING

Содержание CX6500E

Страница 1: ...t intended to be used in a critical life support application Failure to adhere to this warning could result in death or serious injury MODEL ________________________ SERIAL ________________________ DA...

Страница 2: ...1 Transporting Tipping of the Unit 11 Starting Pull Start Engines 12 Starting Electric Start Engines 12 Generator Shut Down 12 Low Oil Level Shutdown System 12 Section 4 Maintenance and Troubleshootin...

Страница 3: ...ughout this publication and on tags and decals affixed to the generator DANGER WARNING CAUTION and NOTE blocks are used to alert personnel to special instructions about a particular operation that may...

Страница 4: ...hair and appendages away from moving parts Failure to do so could result in death or serious injury 000108 WARNING Hot Surfaces When operting machine do not touch hot surfaces Keep machine away from c...

Страница 5: ...the Authority Having Jurisdiction AHJ for any local codes or standards which may be appli cable to your jurisdiction 000144 DANGER Electrocution Contact with bare wires terminals and connections while...

Страница 6: ...14 17 1 120 Volt AC 20 Amp GFCI Duplex Receptacle 2 120 Volt AC 30 Amp Locking Receptacle NEMA L5 30 CX8000E only 3 120 240 Volt AC 30 Amp Locking Receptacle NEMA L14 30R 4 Circuit Breakers AC 5 Off O...

Страница 7: ...cifications 6 5 kW 8 0 kW Generator Specifications Rated Power 6500 Watt 8000 Watt Surge Power 8125 Watt 10000 Watt Rated AC Voltage 6 5 and 8 0 kW 120 240 Rated AC Load 6 5 kW 8 0 kW 54 2 27 1 Amps 6...

Страница 8: ...Hz single phase loads requiring up to 6480 watts 6 4 kW of power at 27 Amps The outlet is protected by two 27 Amp 2 pole connected toggle circuit breakers CX8000E Use this receptacle to operate 120 V...

Страница 9: ...through axle 4 Bend tabs of cotter pins outward to lock into place Install frame foot assembly as follows 1 Slide M8 flat washer 8 rubber foot 5 foot spacer 4 onto M8 x 80 bolt 10 2 Align through hole...

Страница 10: ...the black cable to the negative battery terminal with the bolt and nut sup plied Slide rubber boot over the negative battery terminal and connection hard ware 5 Make sure all connections are secure N...

Страница 11: ...area around fuel cap and remove cap slowly 4 Slowly add recommended fuel Do not fill above red fuel indicator A See Figure 2 10 5 Install fuel cap Figure 2 10 Add Recommended Fuel NOTE Allow spilled...

Страница 12: ...f the generator is used at a construction site there may be additional regulations which must be observed Connecting the Generator to a Building Electrical System When connecting directly to a buildin...

Страница 13: ...e for wattage requirements Table 3 Wattage Reference Guide Transporting Tipping of the Unit Do not store or transport the unit at an angle greater than 15 degrees Device Running Watts Air Conditioner...

Страница 14: ...in the START position When engine starts release the switch to the ON position 6 When engine starts move choke knob to 1 2 choke position until engine runs smoothly then fully to ON position If engin...

Страница 15: ...ed NOTE DO NOT use a garden hose to clean generator Water can enter engine fuel system and cause problems If water enters generator through cooling air slots some water will be retained in voids and c...

Страница 16: ...n area around oil fill and oil drain plug 4 Remove oil fill cap 5 Remove oil drain plug and drain oil com pletely into a suitable container 6 Install oil drain plug and tighten securely 7 Slowly pour...

Страница 17: ...or oper ate the engine on any forest covered brush covered or grass covered land unless the exhaust system is equipped with a spark arrester as defined in Section 4442 main tained in effective working...

Страница 18: ...If fuel stabilizer is added to fuel system pre pare and run engine for long term storage Run engine for 10 15 minutes to circulate sta bilizer throughout fuel system Adequately prepared fuel can be s...

Страница 19: ...5 Stale fuel 6 Dirty fuel filter 7 Spark plug wire not connected to spark plug 8 Bad spark plug 9 Water in fuel 10 Overchoking 11 Low oil level 12 Excessive rich fuel mixture 13 Intake valve stuck ope...

Страница 20: ...18 No battery charge DC output 1 Battery posts corroded 2 Bad battery cable 3 Defective battery 4 Bad receptacle 1 Clean battery posts 2 Replace cable 3 Check battery condition Replace if defective 4...