STOPPING THE GENERATOR
To stop the generator:
1. Turn off, then unplug all connected electrical devices.
2. Switch the circuit breaker to the "off' position.
3. Allow the generator to run for several more minutes with no electrical devices
connected. This helps stabilize the temperature of the generator.
4. Set the engine switch to the "off' position.
5. Turn the fuel valve to the "off' position.
WARNING:
Allow the generator to cool for several minutes before touching
areas that become hot during use.
CAUTION:
Allowing gas to sit in the generator tank for long periods of time without
use can make it difficult to start the generator in the future. Never store generator for
extended periods of time with fuel in the tank.
MAINTENANCE /CARE
Proper routine maintenance of your generator will help prolong the life of your machine.
Please perform maintenance checks and operations according the schedule in figure 13.
CAUTION:
Never perform maintenance operations while the generator is running.
Recommended Maintenance schedule
Each
use
Every
month or
12 hrs
Every 3
months or
50 hrs
Every 6
months or
100 hrs
Every
year or
300 hrs
Engine oil
Check level
×
Replace
×
Air cleaner
Check
×
Clean
×
Fuel filter
cup
Clean
×
Spark plug
Check/clean
×
Gas tank
Check gas
level
×
Clean
7
×
Figure 13- Recommended maintenance schedule
Cleaning the Generator
Always try to use your generator in a cool dry place. However, in the event your generator
becomes dirty you may clean the exterior with one or more of the following:
- A damp clothe
- A soft brush
- A vacuum
- Pressurized air