![Powerhouse M 8539 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/powerhouse/m-8539/m-8539_quick-start-manual_1589504005.webp)
Battery Capacity
.
SET
1
. +
2. +CCA or EN+ Set the battery standard CCA or EN***
3. +CCA/EN value+ input the battery CCA or EN value***
***markings on a battery will state the battery standard and value
If CCA or EN values not stated, select CCA and use the following table
CCA
1000-1299cc 300 CCA
1300-1599cc 400 CCA
1600-1999cc 500 CCA
1600-1999cc 500 CCA
2000-2999cc 700 CCA
3000-3500cc 800 CCA
4. Actual battery value is displayed plus capacity %
Good, check or bad status displayed
Good>74%, check 50-74% and bad <50%
This function will not operate if the battery voltage is less than 8v
Memory Saver
The memory saver function allows the vehicle electrical and audio settings to be retained when the battery is removed.
1. Connect the SmartCharge battery clips to po) and negative(-) cables on the vehicle that attached to
the battery terminals
2. With the AC mains power connected press the Auto Charge button for 5 seconds. Memory Saver mode is
activated when MEM is displayed on the LCD display
3. Remove the vehicle battery
4. Ensure the vehicle battery is connected correctly before disengaging the SmartCharger to ensure no loss of
Vehicle / audio settings
AUTO
CHARGE
AUTO
CHARGE
5 Seconds
Code Detail Reason Action
F01
F01
Battery voltage below 12v
after charging for 300mins
If after 20 hours(
fi
ve times in Recondition
mode) due to a faulty battery, the
battery does not enter th
e fl
oat stage
Battery is defective
or Load maybe connected to the battery
Battery is sulphated
beyond reconditioning
Replace the battery
Disconnect load from the battery
Replace the battery
F02
Battery voltage too high
Battery rated above 12v
Check the battery rating
F03
Actual charging rate
exceeds the charge rate set
Charger error
or Interference from another device
Disconnect the charger and the AC supply, then
reconnect, if error happens again charger faulty
Turn off/ disconnect other devices
that may caues interference.
F04
Charger temperature too high
High ambient temperature
or Poor ventilation
Select a lower charging current to charge
Allow the charger to cool for 30mins
Ensure enough space for adequate
ventilation(10cm clearance)
F05
Does not ente
r fl
oat stage within 24hrs
Charge current too low
or Load maybe connected to a battery
or Battery is defective
Disconnect battery and AC supply.
Reconnect and select a higher charging rate
Disconnect load from battery
Replace the battery
F06
Reverse polarity
Battery clips connected incorrectly
Re-connect the battery clips correctly
Check regulator
Poor functioning regulator
F07
Measured charging voltage is too
high during the alternator test
F08
Measured charging voltage is too
low during the alternator test
Belt maybe loose
or Poor functioning alternator
Check belt and alternator
Input Voltage AC
Charging Voltage
Charging Current
Types of Battery
Dimensions
Weight
200-240VAC, 50Hz
14.4v(winter 14.6v)- Standard vehicle
14.6v(winter 14.8v)- START/STOP(AGM)
Up to 12A Max
Lead acid, Gel, Calcium, AGM, EFB
14-220Ah (Charging)
195x138x78
1.51Kg
11
Operation- Battery Analysing
Operation- Memory Saver
Operation- Fault Codes
14
Speci
fi
cations
8
9
SET
SET
12
13