Summary of Important Safety Information for Operation
53
Moving parts
. Keep hands, feet, and apparel away from drive belts, fans, and other moving parts. Never remove
any drive belt or fan guard while the unit is operating.
Refueling
. DO NOT refuel the engine until it has cooled at least two minutes.
Malfunction during operation.
Immediately turn off the generator if any of the following conditions arise during
operation:
o
Excessive change in engine speed, slow or fast
o
Overheating in load connecting devices
o
Sparking or arcs from generator
o
Loss of electrical output
o
Receptacle damage
o
Engine misfire
o
Excessive vibration
o
Flame or smoke
o
Abnormal noise
Adjusting / repairing
. Always turn off generator and remove spark plug(s) or spark plug wire(s) before working on
the generator to prevent accidental starting.
Safety – After use
Cool engine before storing.
Let engine cool for at least five minutes before storing. A hot engine can be a fire
hazard.
Shut off fuel supply.
Make sure gasoline shut-off valve is in the OFF position.
Prevent accidental starting.
When generator is not in use, remove key from starter (key start engines) and secure
in a safe location, or remove spark plug(s) in order to ensure that generator cannot be started in a storage location or
by untrained persons.
Storage location.
Store the generator in a dry location away from sources of heat, open flames, sparks or pilot
lights – such as water heaters, space heaters, furnaces, clothes dryers, or other gas appliances – EVEN IF the
generator’s gas tank is empty. Residual gasoline could ignite.
Exercise regularly.
Exercise generator every four weeks to dry out moisture that accumulates in the windings. If
generator cannot be exercised on a regular basis, prepare generator for long term storage.
Periodic maintenance.
Perform periodic maintenance as directed in this manual to keep the generator in safe
working condition.
Safety - Inspection/Maintenance
Inspect and maintain your generator on a regular basis and repair as needed to keep it in safe working condition:
Turn off generator
. Always turn off generator and remove spark plug(s) or spark plug wire(s) before working on
the engine or generator to prevent accidental starting.
Discharge capacitor.
When the generator is shut down, the capacitor may maintain a charge. Always discharge the
capacitor before working on the generator head to prevent electrical shock.
Replace guards / shields.
Make sure all guards and shields are replaced after servicing the generator.
Replacement parts.
If a part needs replacement, only use parts that meet the manufacturer’s specifications.
Replacement parts that do not meet specifications may result in a safety hazard or poor operation of the generator
and will void the warranty.
Содержание M792220B
Страница 2: ...Hazard Signal Word Definitions 2...
Страница 8: ...Safety Label Locations 8 2 3 4 5 1 6 7 8 9...
Страница 54: ...Generator Exploded View Rev B 54...
Страница 58: ...Generator Kit Exploded View Rev B 58...
Страница 74: ...74 Distributed by Northern Tool Equipment Co Inc Burnsville MN 55306 NorthernTool com Made in China...